PA0338X00X D-Box Installation
Installing the PA0338X00X D-Box
Page 26
MDE-4318D Competitive Pump and CRIND (CPC) Hardware/Software Start-up and Service Manual · May 2010
Preparing the D-Box
To prepare the D-Box, proceed as follows:
1
Loosen the two screws under the bottom front area of the D-Box and then lift the lid.
2
Carefully remove and discard any packing material from the D-Box.
3
Disconnect the cable from the distribution board(s) at P101 (refer to
“Configuring the D-Box Jumper Settings”
on
for connector locations).
4
Slide the distribution board mounting plate and boards up and out of the D-Box. This
avoids unnecessary damage to the components when you mount the unit to the wall.
Installing the D-Box
To install the D-Box, proceed as follows:
1
Power down the equipment to which the D-Box will be connected (for example,
CAT/DPTs and dispensers, SPC, TED, TRAC Controller, and so on). This step ensures
that there is no damage to the inputs on the connected equipment and that they initialize
properly with the Passport system.
2
Mount the D-Box to the wall ensuring that you allow clearance on the left side to connect
the AC cable, on the right side to connect the Tokheim 67 Box, if applicable, and above, so
that the cover can be removed. The D-Box must also be within 6 feet of the closest AC
receptacle.
3
Install the conduit for the data wires between the wiring trough and the D-Box.
4
Pull the data wires up and into the D-Box leaving 16 inches of wire inside the D-Box (this
step allows for easy installation of the wiring pigtails, explained later in this section).
5
Connect the data wires to the R19263-G1 wiring pigtails (refer to
“Connecting Field Wires to MTA Pigtails”
for instructions).
Note: If jumpers are installed on the unused pigtail positions, cut the unused pigtail loops
connected to the T20488-G2 Board, and cap the wires with wire nuts. If jumpers are
not installed in the unused pigtail positions, then do not cut the unused pigtail loops.
6
Replace the distribution board mounting plate.
7
Reconnect P101.
8
Connect P106, P107, P108, and P109 as required to the board(s).
9
Connect the Data Cable(s) to the 8-pin modular jack connectors.
10
Verify if the jumper settings are correct. Refer to
“Configuring the D-Box Jumper Settings”
on
11
Install the jump jacks (JP1–JP8, Q13804-01) one at a time for the positions being used.
The jumper may be offset by two positions to connect only one pair.