Installation
Page 18
MDE-3801 TRIND™ Multi 1 Transmitter/Receiver in Dispenser Retrofit Kit • 10/99
Connecting Remaining Cables
1
From A side, pass J250 end of cable R20437-G01, J176 and JA ends of cable R20665-G1 and
J177 and PA ends of cable R20665-G2 through card cage to B side.
2
From B side, connect J176 on cable R20665-G1 to P176 on Power Supply PCB.
Note: Detailed information provided on “Cable Block Diagrams” on page 24.
3
Connect J177 on cable R20665-G2 to P177.
4
Connect JA on R20665-G1 to PA on R20724-G1 cable.
5
Connect PA on R20665-G2 cable to JA on R20724-G1 cable.
6
Connect J250 on ribbon cable R20437-G01 to P250 on Gateway board on top of card cage.
From A side of unit make the following connections:
1
On ribbon cable R20437-G01, connect J258A to P258 on A side CRIND Logic Board.
Note: A side of split cable R20437-G01 has red wire.
2
On ribbon cable R20437-G01, connect J258B to P258 on B side CRIND Logic Board.
Connect R20580-G2 power cable according to the following:
Note: Connections are unit specific. Use appropriate connectors to intercept power by
installing R20590-G1 inline.
For units with:
Do the following:
System cable W02468
Install inline using 15 pin P601 and J601 connectors
System cable T19612
Install inline using 3 pin connectors J601/J708 and P601/P708
P186
P176
P177
JA and PA connectors on R20724-G1
pass cables
through cage
P250 on
Gateway Board