Gilbarco PAM 5000 Скачать руководство пользователя страница 7

 

 

 
6.

 

Port 21 DMB- This port is used supplying power for CRIND loop #1 

7.

 

Port 22 DMB- Not Used 

8.

 

Port 23 DMB- Not Used 

9.

 

Port 31 LON- Not Used 

10.

 

Port 32 LON- Not Used 

11.

 

Port 41 Ethernet- This port has an Ethernet cable connecting to it, which leads to 
an external Ethernet port. That is used for downloading software to the CPB.  

12.

 

Port 1/Service Port- This is a RS-232 connection that can also be used for 
downloading software to the CPB. It can also be used for Servicing and 
Diagnostics  

13.

 

Power Supply Connector- 3-Pin connector from the Transformer connects here 

14.

 

Keyboard- The CPB has a 5-key keyboard called a local service panel that is used 
to access some programming if a laptop is not available. * 

Does not access all 

programming

 

15.

 

Display- The display is used in conjunction with the keyboard so programming 
options can be seen 

16.

 

Test Connector- This connector is not used 

17.

 

BDM Connector- This connector is not used 

18.

 

JTAG Interface- This connector is not used at this time 

19.

 

& 20- Sockets for LON options (These are not used at this time) 

 
 
 
The CPB is a microprocessor-based controller for use in the PAM 5000 forecourt 
controller system. It is equipped with the following: 

 

5 DSB ports 

 

3 DMB ports 

 

1 Ethernet interface 

 

2 LON interfaces (add on options) 

 

16MB Flash memory for application software 

 

4MB SRAM for data memory 

 
A keyboard consisting of 5 keys together with a 32-character LCD display makes it 
possible to adjust and monitor several parameters without the need for connecting an 
external PC.  
 
A battery is used for data and real-time clock in case of a power failure. 
 
 
 
 
 
 
 
 

Содержание PAM 5000

Страница 1: ...1 Gilbarco PAM 5000 Launch Package...

Страница 2: ...ssary of Abbreviations Terms Manual References Tools Required System Overview What is a Gilbarco PAM 5000 Where when is it used Why the change Features Benefits Commissioning the Equipment Parts Descr...

Страница 3: ...1000 HIM Hardware Interface Module DSB DMB LAN Local Area Network PAM Pump Access Module PORT A physical serial communication port for connection to hardware modules POS Point of Sale PSU Power Supply...

Страница 4: ...ent protocol options 24 or 36 Pump support The physical serial interface to the POS is based on Hardware Interface Module HIM DSB 500 supporting RS232 RS422 or CL 45mA passive selectable at the wiring...

Страница 5: ...or via web Port statistics errors can be monitored Transaction and device status monitoring Port communication log Can see which ports are communicating Adds remote diagnostics to troubleshoot POS to...

Страница 6: ...connecting to the PAM 2 Port 12 DSB This port is used for pump loop 1 FP1 16 default or 1 12 3 Port 13 DSB This port is used for pump loop 2 FP17 32 default or 13 24 4 Port 14 DSB This port is used fo...

Страница 7: ...ot available Does not access all programming 15 Display The display is used in conjunction with the keyboard so programming options can be seen 16 Test Connector This connector is not used 17 BDM Conn...

Страница 8: ...cable The Current Loop Interface Board uses ports 12 through 14 which are located on the Central Processor Board Each board is equipped with 8 LEDs for status indications It supports the required 45ma...

Страница 9: ...5 0 volt idle voltage This voltage makes the sum of the idle pump load the connection wire drop and the noise margin RS 232 RS 422 CL Interface Module DBS 500 Part M08037B002S RS 422 POS connection T...

Страница 10: ...6678 DSB cable mini 2 7 7cm DSB no 23 M08037B007 135695 DSB cable 7 8 42cm DSB no 33 M08037B008 133088 AC Filter without fuse holder add M8037B004 to complete M08037B009 140109 Power Supply Transforme...

Отзывы: