background image

MDE-5440B Heater/Fan Kit (M14702K00X) Installation Guide for Encore® 900 Units · October 2021

Installing the Heater/Fan Kit for Encore 900

Page 7

Installing the Heater/Fan Kit for Encore 900

In the event of inclement weather, including snow, ice, or flooding that makes driving 
conditions dangerous, please avoid servicing units. Always use available door stops to 
secure upper doors against unwanted/unexpected movement, especially during high 
winds. If necessary, reschedule service to avoid damage to the equipment. Weather may 
change unexpectedly; be aware of local weather conditions. During service, if conditions 
develop making service unsafe, close the unit(s) and proceed to a safe location.

WARNING

To install the Heater/Fan Kit, proceed as follows:

1

Remove and retain the lower panel.

2

Open the main door.

3

Position the heater so that the cables are on the Side A of the unit [the side with the Pump 
Control Node (PCN)].

4

Place the heater on the section of the U-channel as shown in 

Figure 1

.

Figure 1: Heater Mounting Location

U-channel 
plate shot

Содержание M14702K00 Series

Страница 1: ...dicating that the controller board is trying to turn them on Notes 1 There are no replaceable parts on the assembly 2 There are different assemblies for 115V and 220V units This manual is intended for...

Страница 2: ...5 6 M14702K002 Kit Heater Fan Install 220V Required Tools The following tools are required to complete the Heater Fan Assembly installation 8 mm socket Ratchet Item Description Part Number Quantity H...

Страница 3: ...ature Compensation CPR Cardiopulmonary Resuscitation Methods CSC Customer Specified Contractors DEF Diesel Exhaust Fluid ESD Electrostatic Discharge FCC Technical Assistance Center LED Light Emitting...

Страница 4: ...followed Failure to install inspect maintain or service this equipment in accordance with these codes regulations and standards may lead to legal citations with penalties or affect the safe use and o...

Страница 5: ...so on IMPORTANT Oxygen may be needed at scene if gasoline has been ingested or inhaled Seek medical advice immediately Lockout Tagout Lockout Tagout covers servicing and maintenance of machines and e...

Страница 6: ...site and dispenser for the upgrade proceed as follows 1 Inform the manager 2 Barricade the unit to be worked on 3 Remove power to the unit at the breaker panel Follow OSHA lockout tagout procedures 4...

Страница 7: ...ially during high winds If necessary reschedule service to avoid damage to the equipment Weather may change unexpectedly be aware of local weather conditions During service if conditions develop makin...

Страница 8: ...with the slot on the plate shown in Figure 1 on page 7 Note Ensure that the hook is slid all the way back into the slot Figure 2 Heater Hook Position Heater hook in U channel slot 6 Finish securing t...

Страница 9: ...Power Distribution Cable M04406A006 A007 A008 as shown in Figure 4 For detailed installation instructions of the AC power distribution cable refer to MDE 4535 SMART ConnectAC Power Distribution Cable...

Страница 10: ...te Ensure to route the ribbon cable M06968A001 through the adhesive clamp on the side of the printer cover as shown in Figure 6 If no adhesive clamp is present attach one to the side of the printer co...

Страница 11: ...MDE 5440B Heater Fan Kit M14702K00X Installation Guide for Encore 900 Units October 2021 Installing the Heater Fan Kit for Encore 900 Page 11 This page is intentionally left blank...

Страница 12: ...allation Guide for Encore 900 Units October 2021 Eclipse Encore and Gilbarco are registered trademarks of Gilbarco Inc GOLDSM is a service mark of Gilbarco Inc SMART Connect and Ultra Hi are trademark...

Отзывы: