MDE-5440B Heater/Fan Kit (M14702K00X) Installation Guide for Encore® 900 Units · October 2021
Installing the Heater/Fan Kit for Encore 900
Page 9
Connecting Cables in Encore 900 Units
To connect the cables in the Encore 900, proceed as follows:
1
Connect the heater AC power cable (black and white wire; M06969A003/A004) to any of the
available positions of the Power Distribution Cable (M04406A006/A007/A008) as shown in
.
For detailed installation instructions of the AC power distribution cable, refer to
MDE-4535 SMART Connect
AC Power Distribution Cable Installation.
Notes: 1) M04406A006 is used on standard Encore units, M04406A007 is used on domestic
Ultra-Hi
™
units, and M04406A008 is used on international Ultra-Hi units.
2) Ensure to route the AC power cable through an adhesive cable clamp in the
U-channel as shown in
(ii).
Figure 4: AC Power Cable Connections
Cable connection
Adhesive clamp
(i)
(ii)
(iii)