![GILBARCO VEEDER-ROOT Encore 700 S Скачать руководство пользователя страница 56](http://html.mh-extra.com/html/gilbarco-veeder-root/encore-700-s/encore-700-s_start-up-and-service-manual_2227131056.webp)
Activating Encore 700 S CRIND
Configuring/Activating Encore 700 S CRIND
Page 5-4 MDE-4902E Encore® 700 S Start-up and Service Manual · February 2018
The options in the Service Menu are shown in
.
Figure 5-6: Service Menu Options Tree
Service Menu
Setup Menu
Security Setup Menu
System Configuration Menu
1-IP Address
2-Net Mask
3-DHCP Client
4-Date/Time
1-Unit Activation
2-TR-31 Activation*
3-Reader Warning
4-SRED Activation**
1-Contact Card Reader
2-Printer Port
3-Contactless Card Reader
4-Mode Select*
*TR-31 Activation - Disables some Secure Payment Outdoor Terminal (SPOT) commands to enforce compliance with
the TR-31 Key Loading standard.
**Secure Reading and Exchange of Data (SRED) Activation - Enforces the SRED configuration which:
• Provides a higher level of security.
• Enables selection of Transport Layer Security (TLS) secure connection.
• Changes the green screen menus and timeouts.
Note: Mode Select is available on Bundle 6X.Y.ZZ only.
5
Press
2
>
Enter
to enter the Security Setup Menu.
This menu is used to activate security mounting sensors.
The Encore 700 S CRIND software modules are not activated and system communications are
not possible until the unit’s mounting sensors are activated.
The menu displays the following:
• UNIT SERIAL NUMBER: PPN shown at start-up.
• UNIT CHALLENGE NUMBER: Variable code generated when the Encore 700 S CRIND
device starts.
• ENTER MATCHING PASSWORD: Matching password is the answer to the challenge
number.
Note: Gilbarco Technical Support Center/Service Center creates the MATCHING
PASSWORD by a secure process that uses the serial number and challenge number,
and produces a unique matching password. It must be entered within a time limit
(three minutes) of the challenge number being displayed, else, the screen times out
and reverts to the main Service Menu.
If IP address changes are required, they must be changed using CRIND diagnostics.
Using the Service Menu to change IP Addresses may result in communication issues
with the dispenser.
WARNING
WARNING
!