background image

 

 

Capricorn Pro 4 Installation Note 

 

DCP0000264(A)

 

Connecting the Power 

 

  

 

Warning 

T

O REDUCE THE RISK OF ELECTRIC SHOCK

,

 DISCONNECT ALL POWER CORDS BEFORE SERVICING THE UNIT

.

 

 

 

 

The Capricorn CPE is powered with a 48VDC external power source. The CPE power connection uses the 
optionally supplied Gilat power cables (CB000912) that include a 7A fuse on the “+” wire. An 

accessible

 two 

pole circuit breaker (Rated 10A) must be provided in the building for the DC power feed source 

 

 

In case of dual power supplies connect both inputs to the relevant power sources. 

Connecting LAN Cable

 

Use only shielded CAT-5 type cables (approved by Gilat) to connect to the LAN port.  
Use the LAN LEDs indicators to make sure that the LAN ports are operational. 

 

Connecting RF Cable 

Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown 
below, using a recommended torque of 13 lb*ft/in (1.5 N/m). 

 

 

C

AUTION

 

T

O PREVENT DAMAGE TO THE 

RF

 

C

ONNECTORS

,

 SECURE THE CABLES TO A PERMANENT

,

 STATIC OBJECT 

SUCH  AS  A  TABLE  OR  PIPE

,

  AT  A  DISTANCE  OF 

25-60

  CM 

(10-25

  IN

.)

  FROM  THE 

CPE,

  PRIOR  TO 

CONNECTION

.

 

 

 

 

Figure 1: Capricorn Cables

 

 

Figure 2: Capricorn MEC Rack-Mount 

(Optional) Attaching Rack Mount Back Ears 

To install the CPE with the rear panel facing forward: 
1.

 

Remove the screws holding the rack-mount front ears. 

2.

 

Remove the rack-mount front ears. 

3.

 

Secure the screws to the front panel. 

4.

 

Remove the screws from the rear panel. 

5.

 

Unpack the rack-mount back ears from the installation kit 

6.

 

Install the rack-mount back ears to the rear panel and tighten the screws.

 

 