Capricorn Pro 4 Installation Note

 

 

DCP0000250(B)

 

The Capricorn CPE can be powered in local AC power. The power connection is as follows:  

 

For AC power, use the power cord supplied by Gilat.  

 

In case of dual power supplies connect both inputs to the relevant power sources.

 

 

AC Main source: “readily accessible two pole circuit breakers should be provided in the building installation", 

Rated 5A.  

Connecting LAN Cable

 

Use only CAT-5 type cables to connect to the LAN port.  

 

Connecting RF Cable 

Connect the two RF cables (from the LNB and ODU) to the RF-IN and RF-OUT connectors, respectively, as shown 

below, using a recommended torque of 13 lb*ft/in (1.5 N/m). 

 

 

C

AUTION

 

T

O PREVENT DAMAGE TO THE 

RF

 

C

ONNECTORS

,

 SECURE THE CABLES TO A PERMANENT

,

 STATIC OBJECT 

SUCH AS A TABLE OR PIPE

,

 AT A DISTANCE OF 

25-60

 CM 

(10-25

 IN

.)

 FROM THE 

CPE,

 PRIOR TO CONNECTION

.

 

 

 

 

Figure 1: Capricorn Cables

 

 

 

Figure 2: Capricorn Rack-Mount 

(Optional) Attaching Rack Mount Back Ears 

To install the CPE with the rear panel facing forward: 

1.

 

Remove the screws holding the rack-mount front 

ears. 

2.

 

Remove the rack-mount front ears. 

3.

 

Secure the screws to the front panel. 

4.

 

Remove the screws from the rear panel. 

5.

 

Unpack the rack-mount back ears from the 

installation kit 

6.

 

Install the rack-mount back ears to the rear panel and 

tighten the screws.

 

 