STEP 04 :
MAHA-PLUS must be installed
that the glass surface of the
product is horizontal
‘0’ degree to the ground.
[ X ]
[ O ]
DC Cable
MAHA-PLUS Series
Installation Guide
LED Flood Lighting
Model : MAH1K0 (Remote Driver Type)
Installation Instruction (2/4)
Document Revision_
220524_EU
0°
Ground
over
0°
0°
Ground
X
O
STEP 05 :
Please match the cable colors as
shown.
Conductor termination
Open the clamping unit using the lever and insert
conductor. Then, lower the lever to close the clamp.
Important : Make sure they are clamped tightly.
DC+
DC-