8
Installing the Gigaset HC450 door intercom system
Gigaset HC450 / en / A31008-M1799-R101-2-7619 / Starting.fm / 08.10.2008
Ve
rs
io
n 4, 16.0
9.20
05
Surface mounting
u
Remove the bell button if there is one
and unscrew the cables. Fit the frame
over the cable outlet. Next screw one of
the enclosed green clamping plugs to
the existing 2-core bell cable (polarity is
not relevant here) and insert it in the
jack with the ETS symbol (green jack).
u
Hang the door intercom at the top of
the frame (45 degree angle, see illus-
tration on right) and lower it against
the wall. Fix the door intercom using
the two enclosed hexagon socket
screws.
Caution:
If you are using the existing bell cable, the
doorbell system must be set to zero potential
prior to installation.
Caution:
Cables must not be connected or disconnected
during a thunderstorm.
VoIPon www.voipon.co.uk [email protected] Tel: +44 (0)1245 808195 Fax: +44 (0)1245 808299