CAUTION

An all-pole mains switch with a contact separation of at least 3 mm in each pole shall be incorporated in the 

electrical installation of the building.

When Installing the Unit
•  Never plug in nor remove the power supply plug with 

wet hands, as doing so may cause electric shock.

•  When unplugging the power supply cord, be sure to 

grasp the power supply plug; never pull on the cord 

itself. Operating the unit with a damaged power sup-

ply cord may cause a fire or electric shock.

•  When moving the unit, be sure to remove its power 

supply cord from the wall outlet. Moving the unit with 

the power cord connected to the outlet may cause 

damage to the power cord, resulting in fire or elec-

tric shock. When removing the power cord, be sure 

to hold its plug to pull.

•  Do not block the ventilation slots in the unit’s cover. 

Doing so may cause heat to build up inside the unit 

and result in fire.

•  Avoid installing the unit in humid or dusty locations, 

in locations exposed to the direct sunlight, near the 

heaters, or in locations generating sooty smoke or 

steam as doing otherwise may result in fire or elec-

tric shock.

When the Unit is in Use
•  Do not place heavy objects on the unit as this may 

cause it to fall or break which may result in personal 

injury and/or property damage. In addition, the object 

itself may fall off and cause injury and/or damage.

•  Make sure that the volume control is set to mi-

nimum position before power is switched on. 

Loud noise produced at high volume when power is 

switched on can impair hearing.

•  Do not operate the unit for an extended period of 

time with the sound distorting. This is an indication 

of a malfunction, which in turn can cause heat to ge-

nerate and result in a fire.

•  Contact your dealer as to the cleaning. If dust is al-

lowed to accumulate in the unit over a long period of 

time, a fire or damage to the unit may result.

•  If dust accumulates on the power supply plug or in 

the wall AC outlet, a fire may result. Clean it perio-

dically. In addition, insert the plug in the wall outlet 

securely.

•  Switch off the power, and unplug the power supply 

plug from the AC outlet for safety purposes when 

cleaning or leaving the unit unused for 10 days or 

more. Doing otherwise may cause a fire or electric 

shock.

Содержание GGM IPAP1120

Страница 1: ...GGM IPAP1240 GGM IPAP1350 GGM IPAP1500 USER MANUAL www gigamedia net Please follow the instructions in this manual to obtain the optimum results from this unit We also recommend that you keep this manual handy for future reference ...

Страница 2: ...eatment and recycling of used batteries you can return them to your dealer deposit them in a collection bin provided for this purpose or return them to your municipal waste which is obliged to recover them WEEE regulation This product is covered by the WEEE II Directive Directive 2012 19 EU It should not be thrown in the trash or dumped Substances in the product may be hazardous to human health or...

Страница 3: ...luding the unit itself on the power cord as doing so may result in fire or electric shock Be sure to replace the unit s terminal cover after connection completion Because high voltage is ap plied to the speaker terminals never touch these terminals to avoid electric shock Be sure to ground to the safety ground earth ter minal to avoid electric shock Never ground to a gas pipe as a catastrophic dis...

Страница 4: ...near the heaters or in locations generating sooty smoke or steam as doing otherwise may result in fire or elec tric shock When the Unit is in Use Do not place heavy objects on the unit as this may cause it to fall or break which may result in personal injury and or property damage In addition the object itself may fall off and cause injury and or damage Make sure that the volume control is set to ...

Страница 5: ... 08 Two AUX outputs connect with external amplifier standard interfaces RCA port Wiring connection is very convenient 09 One three wire volume with relay output without forced cutting power supply compatible with four wire fire cutting need to connect with 24V power supply 10 Built in intelligent power management automatically cut off the amplifier power when no signal input power amplifier automa...

Страница 6: ...shut down the equipment 06 Power LED the LED lights on when switches on the equipment it lights off when shuts down the equipment 07 PROT Protection indicator 08 OUTPUT LEVEL Level indicator 09 FINE Status indicator 10 IR Infrared receiving window 11 TREBLE adjust the response of treble Increase treble output by knob clockwise rotation and decrease it by knob anticlockwise rotation 12 BASS adjust ...

Страница 7: ...voltage speakers 100 V port is connectable with 100 V constant voltage speakers 03 Signal output port of volume control 04 Signal input port of volume control 05 Mute potentiometer turn the knob to the rightmost the mute level is the maximum and turn the knob to the leftmost the mute level is the minimum 06 Aux audio source input 07 EMC input port 08 Line output port 09 RJ45 network interface conn...

Страница 8: ...en you will have to press the button Inquire Figure 1 to display the equipments found by iptool Figure 2 You will now have to change the IP address of your equipment to match the IP addresses of your network You need to fill every field below New terminal Figure 3 Once all the fields are filled press the button Write to apply the configuration and check with the button Ping to see if it is reachab...

Страница 9: ...VIO U S O N O FF POWER VOL P L AY M S G M IC in P L AY S IR E N R E C i n O N O FF S TA N D B Y PL AY A L A RM M O D E RECO RD S TO P S TA RT ON OFF P O WE R CL IP TEMP VOL U ME PROT 5 0 1 2 3 4 6 7 8 9 10 S IG N AL speaker speaker Three wire tone control CD MP3 player Alarming signal generator Power amplifier Ethernet switch ...

Страница 10: ...S ON OFF POWER VOL P L AY M S G M IC in P L AY S IR E N R E C i n ON OFF S TA N D B Y PL AY A L A RM M OD E RECO RD S TO P S TA RT ON OFF P O WE R CL IP TEMP VOL U ME PROT 5 0 1 2 3 4 6 7 8 9 10 S IG N AL Speaker Speaker Three wire tone control Ethernet switch CD MP3 player Alarming signal generator Power amplifier ...

Страница 11: ...X output amplitude 1000 mV 2 RCA output AUX output impedance 470 Ω Treble adjustment range 10 5 dB Bass adjustment range 10 5 dB Rated power 120 W 240 W 350 W 500 W Power consumption 180 W 370 W 540 W 750 W Standby power consumption 3 W Frequency response 80 Hz 16 kHz 3 dB 0 dB THD THD 1 SNR 65 dB Speaker output 70 V 100 V 4 16 Ω Protection DC output High temp overload and short circuit Operation ...

Отзывы: