5. TERMINAL CONFIGURATION OPERATING INSTRUCTIONS

The

 

configuration

 

steps:

Step

 

1:

 

Connect

 

the

 

terminal

 

and

 

the

 

computer

 

installed

 

with

 

the

 

terminal

 

configuration

 

tool

 

program

 

by

 

the

 

network

 

wire

Plug

 

in

 

the

 

power

 

until

 

the

 

termianl

 

power

 

indicator

 

is

 

on

.

Step

 

2:

 

double-click

 

to open

 

the

 

shortcut

 

icon

 

of

 

“terminal

 

configuration

 

tool”,

 

select

 

the

 

network

 

card

 

first,

 

and

 

left-click

 

the

 

“query”

 

button

 

in

 

the

 

window

to

 

query

 

the

 

terminal’s

 

original

 

IP

 

address

Please

 

pay

 

attention

 

to

local

 

IP

 

address

 

of

 

the

 

computer

 

should

 

be

 

set

 

in

 

the

 

same

 

network

 

segment

 

as

 

the

 

terminal

because

 

the

 

default

 

IP

 

of

 

terminal

 

is:

 

192

.

168

.

168

.

166,

 

so

 

the

 

computer

'

s

 

local

 

IP

 

address

 

should

 

also

 

be

 

set

 

to:

 

192

.

168

.

168

.

X,

 

otherwise

 

it

 

maybe

 

not

 

match

 

the

 

IP

 

terminal

 

address

.

Step

 

3:

 

In

 

the window

 

of

 

“Terminal

 

Configuration

 

Tool”,

 

fill

 

in

 

correct

 

“IP

 

address”,

 

“Subnet

 

mask”

“Gateway

 

IP”

 

and

 

“Server

 

IP”,

 

as

 

below:

Step

 

4:

  

left

 

click

 

on

 

the

 

“write”

 

button

there

 

will

 

be

 

a

 

window

 

prompt

 

after

 

the

 

successful 

configuration;  after

 

that

left

 

click

 

on

 

the

 

“query”

 

button,

 

the

 

parameters

 

of

 

the

 

terminal will

 

be

 

re-read

 

by

 

the

 

configuration

 

program,

 

if

 

it

 

display

 

as

 

the

 

same

 

as

 

entered

 

one, means

 

that

 

the

 

configuration

 

was

 

successful

.

WWW.GIGAMEDIA.NET

Содержание GGM IPABC15POE

Страница 1: ...e optimum results from this unit We also recommend that you keep this manual handy for future reference IP NETWORK PA SYSTEM POE LAN BATT SUPPLY 24V 2A STATE IP 192 168 169 169 OWNER S MANUAL GGM IPABC8POE GGM IPABC15POE NETWORK AUDIO ADAPTER WWW GIGAMEDIA NET ...

Страница 2: ...SAFETY PRECAUTIONS PRODUCT APPLICATION 5 3 FUNCTION FEATURES 5 4 NAME AND UNCTION 5 TERMINAL CONFIGURATION OPERATING INSTRUCTIONS CONNECTION DIAGRAM BLOCK DIAGRAM TECHNICAL PARAMETERS 6 7 6 10 7 10 8 2 WWW GIGAMEDIA NET ...

Страница 3: ...ions of safety symbols and messages regarded as very important precautions are included We also recommend you keep this instruction manual handy for future reference Safety Symbol and Message Conventions Safety symbols and messages described below are used in this manual to prevent bodily injury and property damage which could result from mishandling Before operating your product read this manual ...

Страница 4: ...upply plug or in the wall AC outlet a fire may result Clean it periodically In addition insert the plug in the wall outlet securely Switch off the power and unplug the power supply plug from the AC outlet for safety purposes when cleaning or leaving the unit unused for 10 days or more Doing otherwise may cause a fire or electric shock When Installing the Unit Never plug in nor remove the power sup...

Страница 5: ...he construction is simple and convenient and the maximum connection distance is up to 80 meters 4 Digital power amplifier with intelligent gain adjustment adaptive power supply and automatic power adjustment was equipped And it is always in the working state of performance optimization and efficiency maximization 5 Built in full band and high sensitivity speaker unit also with abundant power and h...

Страница 6: ... green light off 2 Powering on light green on red light off 3 The normal idle alternating red and green alternately 1 0 seconds interval bright red and green two color 4 The normal broadcast bright green on red off 5 The network failure red flash and green off 0 2 seconds interval then bright red on The factory terminal IP address is 192 168 168 166 Subnet mask 255 255 0 0 Gateway 0 0 0 0 Service ...

Страница 7: ...for future maintenance After the system planning is completed please configure parameters of each terminal includes terminal IP address subnet mask gateway and server address 1 Installing software Find the IP network broadcast system software installation package double click to open it click on the program terminal configuration tool after the installation of the program is completed as shown bel...

Страница 8: ...he computer should be set in the same network segment as the terminal because the default IP of terminal is 192 168 168 166 so the computer s local IP address should also be set to 192 168 168 X otherwise it maybe not match the IP terminal address Step 3 In the window of Terminal Configuration Tool fill in correct IP address Subnet mask Gateway IP and Server IP as below Step 4 left click on the wr...

Страница 9: ... in the queried terminals list then cancel the choice of broadcast on the left interface modify the IP address and click for configuration Notes If the terminal data can t be queried or the network is blocked the pop up window will say Reconfigure the IP address or IP adress writing error In this case please reconfigure the network check the network cable and turn off the firewall etc WWW GIGAMEDI...

Страница 10: ...supply Motherboard RJ45 Network board PA3123D2 12V power supply Speakers 6 CONNECTION DIAGRAM 7 BLOCK DIAGRAM POE Switch POE LAN BATT SUPPLY 24V 2A STATE Server Speaker 01 Speaker 02 Speaker N POE LAN BATT SUPPLY 24V 2A STATE POE LAN BATT SUPPLY 24V 2A STATE WWW GIGAMEDIA NET ...

Страница 11: ...3 8K 48K 8K 512Kbps Audio Format Sampling Rate Bit rate 20 80 Relative humidity no condensing 5 40 Working Tempreture Working Humidity POE IEEE 802 3af DC 24V 2A 12W 24W Power Specifications Power Consumption 12W 12W 0 8Kg 1 2Kg N W 180X98 212X147 Dimension mm 160mm Installation dimensions 184mm Overvoltage overcurrent circuit Power protection circuit Woofer Coaxial speakers 8Ω 6W Loaded speakers ...

Страница 12: ...VersionV0 1 IP NETWORK PA SYSTEM ...

Отзывы: