![Gigahertz Solutions ME 3951A Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/gigahertz-solutions/me-3951a/me-3951a_user-manual_2225891013.webp)
Picture 16
Picture 17
Picture 18
Recommended Exposure Limit up to 2 kHz:
Below 200 nT, better yet below 20 nT.
(For frequencies above 2 kHz below 20 nT, better yet below 2 nT)
The resultant, total magnetic field strength (the sum of the single field strengths, 3-D Measure-
ment) can be accurately calculated according to the following equation:
Resultant Field Strength = Square Root(x² + y² + z²)
Picture 19 illustrates the direction of the resultant field, which is also called "substitute field." The
photos for pictures 16 through 18, showing the single measurements of the three dimensions, as
well as picture 20 were taken in a kitchen during a typical testing session. If you would insert the
display values in the above equation, the result would come very close to the value, which is dis-
played in picture 20. There the field meter is held perpendicular to the resultant field.
Picture 19
Picture 20
Res.
y
z
x
13
© by
GIGAHERTZ SOLUTIONS
®
GmbH, 90579 Langenzenn, www.gigahertz-solutions.com
Measurement Instructions
GIGAHERTZ
SOLUTIONS