Getting Started
Connecting the LogPer Antenna
Screw the angle connector of the antenna connection into the up-
permost right socket of the HF analyser. It is sufficient to tighten
the connection with your fingers. (Do not use a wrench or other
tools because over tightening may damage the threads.)
This SMA connector with its gold-plated contacts is the highest
quality commercial HF connector available in that size.
At the tip of the antenna, there are two LEDs for monitoring the
proper function of all connections of the antenna and the cable dur-
ing operation. The red LED checks the cable, the green one the
antenna itself, both ok if the LEDs are lit.
Slide the antenna into the vertical/cross shaped slot at the rounded
top end of the HF analyser. Make sure the antenna cable has no
tension and lies below the instrument. It may help to loosen the
SMA-connector temporarily to let the cable fall into a “relaxed” po-
sition.
Do not bend or stretch the antenna cable!
Both ends of the antenna cable are equipped with small ferrite-rolls
to improve the antenna characteristics.
Do not remove them!
The connection of the omin-antenna UBB27
(available as op-
tional accessory for the HF59B, but included in the HF
E
59B-kit) is
described in the respective manual.
Checking Battery Status
If the “Low Batt” indicator appears in the center of the display,
measurement values are no longer reliable. In this case, the battery
needs to be charged.
If there is no display at all upon switching the analyser on, check
the connections of the rechargeable battery. If that does not help
try to insert a regular 9 Volt alkaline (non-rechargeable) battery (see
chapter on battery change).
Caution:
make sure NOT to connect
the analyser to a power supply unit/AC adaptor while temporarily
operating it with a non-rechargeable battery!
Insert fully charged batteries only.
Note
Each time you make a new selection (e.g. switching to another
measurement range), the display will systematically overreact for a
moment and show higher values which will, however, droop down
within a couple of seconds.
The instrument is now ready for use.
In the next chapter you will find the basics for true, accurate
HF-measurement.