Страница 1: ...User s Manual GS SR125EDL Rack Mount Server Dual XeonTM Processor Motherboard Server Solution Rev 1001 25A08 05EDL C00...
Страница 2: ...isk Drive Installation 14 Step 2 7 FAN Duct Installation 15 Step 2 8 Reinstall Top Cover 15 Chapter 3 Appearance of GS SR125EDL 16 3 1 Front View of GS SR125EDL 16 3 2 Rear View of GS SR125EDL 17 3 3...
Страница 3: ...3 Table of Content Cache Memory 41 I O Device Configuration 43 Console Redirection 45 Security 48 Boot 50 Exit 51 Chapter 6 Appendix 53 6 1 Acronyms 53...
Страница 4: ...nd product usage instructions Do not use this product near water or a heat source Set up the product on a stable work surface or so as to ensure stability of the system Openings in thecaseare provided...
Страница 5: ...own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Neither the provider nor the manufacturer are responsible for any radio or televisio...
Страница 6: ...ntifies certified equipment This certification means that the equipment meets certain telecommunications network protective operational and safety requirements The Department does not guarantee the eq...
Страница 7: ...termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100 for European users only CAUTION...
Страница 8: ...ningthe package please ensurethe system components are not damaged duringtheshipping Using the following checklist to v erify the contents If any component is missing or damaged in the system please c...
Страница 9: ...Error Correction Single bit Errors Correction Multiple bit Errors Detection Expansion Slot 1 x Riser card with one full height full length PCI X 1 x Riser card with low profile half length PCI slot D...
Страница 10: ...Plug and Play A C Power Recovery Server Management Functions Optional BMC Chip NS IPMI 1 5 controller Failure Detection IPMI 1 5 specification of Server management Event Logging 32KB Nonvolatile Memo...
Страница 11: ...f the chassis Step 2 And slide toward to remove the top cover After removing the top cover you can install CPU and other essential components Step 1 To install the CPU s lift up the bar that located n...
Страница 12: ...tall the heat sink just simply put it on the retention module Step 1 Step 2 4 Memory Installation Step 1 The DIMM slot has a notch the DIMM memory module only fit in one direction Step 2 Align the mem...
Страница 13: ...2 Detach the riser bracket with both hands Step 3 Installing the PCI Riser card To install the riser card just simply push it into the module Step 4 Secure the card with screws Repeat Step 3 4 to ins...
Страница 14: ...ray from the chassis Step 2 Insert the hard disk drive into the tray Step 3 Secure each hard disk drive with 4 screws Step 4 After securing the harddisk drive with the screws hold the harddrive handle...
Страница 15: ...y apply force to the indentures with your thumbs and push toward the chassis See the arrow direction to the lock position Step 1 Step 2 7 FAN Duct Installation Step 1 Place the fan duct on the top of...
Страница 16: ...16 GS SR125EDL Rack mount Server 3 1 Front View of GS SR125EDL Chapter 3 Appearance of GS SR125EDL u v w x x w v u IDE HDD USB Connectors System LED CD ROM Disk...
Страница 17: ...ystem Appearance 17 3 2 Rear View of GS SR125EDL x z u v y w PS 2 Keyboard Mouse Connector Low Profile Full Height Full Length LAN 1 2 Ports VGA Port COM Port USB Connectors Power Connector x w v u y...
Страница 18: ...ne Layout and Description A B C E D F G H I J K Q P O M N L T U S R V W X A C D Power G FAN9 F H FAN1 I FAN10 K J FAN2 R IDE1 M L FAN3 S IDE2 O N FAN4 T SMBUS1 P FAN5 U CON1 SCA80 1 Q FAN6 V CON2 SCA8...
Страница 19: ...ands by Off N A No pow er SYS LED On Amber System is ready but degraded some CPU Fault DIMM Killed Critical Pow erModules Failure Critical FANs Failure Voltage Pow er Supply criticalTemperatureand Vol...
Страница 20: ...mount Server 3 5 HDD LED Indicators Description HDD LED 1 HDD LED 2 Acting Color Status HDD LED 1 Off N A HDD power off HDD LED 1 On Green HDD power on HDD LED 2 Off N A HDD non active HDD LED 2 Blin...
Страница 21: ...21 Connector Icon Description 3 6 Connector Icon Description Suggest Icon Description Keyboard VGA Mouse LAN Parallel Port Serial Port USB...
Страница 22: ...mount Server Chapter 4 Motherboard Layout Jumper Setting Introduction GA 8EGPDRE Motherboard Layout 1 2 3 4 5 14 12 16 15 13 10 18 19 20 21 23 22 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41...
Страница 23: ...B6 26 SMBUS2 5 CIOBE 27 FFC1 6 DIMM1 28 PCIXSLOT2 7 DIMM2 29 PCI64_SLOT 8 DIMM3 30 Graphic Memory 9 DIMM4 31 IDE2 10 ATI Rage XL 32 IDE1 11 BIOS 33 IDE3 12 VS312AB 34 FDD1 13 BT1 35 Giga RAID 14 SYS_F...
Страница 24: ...ector 1 Pin No Definition 1 GND 2 12v Control 3 Sense SYS_FAN2 SYS_FAN3 SYS_FAN1 CAUTION v Danger of explosion if battery is incorrectly replaced v Replace only with the same or equivalent type recomm...
Страница 25: ...oper installation of the CPU cooler is essential to prevent the CPU from running underabnormal conditionor damaged by overheating The CPU fan connector supports Max currentup to 600mA Pin No Definitio...
Страница 26: ...26 GS SR125EDL Rack mount Server 20 21 IPMB1 IPMB 2 IPMB Connector 1 Pin No Definition 1 SCl_IPMB 2 GND 3 SDA_IPMB 22 WOL1 Wake on LAN Connector Pin No Definition 1 5VSB 2 GND 3 Signal 1...
Страница 27: ...27 Connector and Jumper Setting Introduction 23 WOM1 Wake on Modem Connector 1 Pin No Definition 1 Signal 2 GND 24 PWRDET1 Power Status Interface Pin Definition 1 I2C_CLK 2 GND 3 I2C_Data 4 NC 1...
Страница 28: ...28 GS SR125EDL Rack mount Server 25 26 SMBUS1 2 SMBUS Connectors Pin Definition 1 VCC 2 SDA 3 SCL 4 NC 5 GND SMBUS1 SMBUS2 1 27 FFC1 IPMB I2C Bus Connector...
Страница 29: ...OT2 Supports full height full length PCI X PCI64_SLOT Supports low profile half length PCI slot 31 32 33 IDE2 IDE1 IDE3 IDE1 IDE2 IDE3Connectors Important Notice Please connect firstharddisk to IDE1an...
Страница 30: ...Server 34 FDD1 Floppy Connector Please connect the floppy drive ribbon cables to FDD It supports 360K 720K 1 2M 1 44M and 2 88Mbytes floppy disk types The red stripe of the ribbon cable must be the s...
Страница 31: ...tion 43 JP9 PCI_SLOT1 Bus Speed Functon 1 1 1 2 close Conventional PCI Mode 2 3 close PCI X 66MHz Default Open Auto 42 JP6 PCIX_SLOT2 Bus Speed Functon 1 1 1 2close SetthePCI XBus Speedat 100MHz 2 3cl...
Страница 32: ...Option Page Setup Menu F2 Reserved F3 Reserved F4 Reserved F5 Restore the previous CMOS value from CMOS only for Option Page Setup Menu F6 Reserved F7 Load the Optimized Defaults F8 Reserved F9 Reser...
Страница 33: ...This setup page include all the items of first boot function features l Exit There are five optionsin this selection Exit Saving Changes Exit Discarding Changes Load Optimal Defaults Load Failsafe Def...
Страница 34: ...ear onthe screen Use arrow keys to select among the items and press Enter to accept or enter the sub menu Figure 1 Main PhoenixBIOS Setup Utility Main Advanced Security Boot Exit System Time 00 13 12...
Страница 35: ...the types ofharddisk from driveC to F that has beeninstalledinthe computer There are two types auto type and manual type Manual type is user definable Auto type which will automatically detect HDD typ...
Страница 36: ...Teansfer Mode 8 Ultra DMA Mode This filed displays the DMA mode of the deviceinthe specific IDE channel C System Memory The POST of the BIOS will determine the amount of base or conventional memory i...
Страница 37: ...lues F5 Setup Defaults Esc Exit fg Select Menu Enter Select4Sub Menu F10 Save Exit Advanced About This Section Advanced This section Advanced is divided into six sub menus E Advanced Processor Option...
Страница 38: ...sabled Disable this function Default 4 Spilt Lock Operation CPU split lock feature setting 8 Enabled Enable CPU spilt lock features 8 Disabled Disable this function Default Figure 2 1 Advanced Process...
Страница 39: ...F10 Save Exit PCI Configuration CPCIConfiguration This section provide the addtional setup menus for users to confiure PCI devices 4 PCI PNP UMB Region Exclusion Reserve specific upper memory blocks...
Страница 40: ...abled Cache B000 BFFF Disabled Cache C800 CFFF Disabled Cache CC00 CFFF Disabled Cache D000 DFFF Disabled Cache D400 D7FF Disabled Cache E000 E3FF Disabled Cache E400 F7FF Disabled F1 Help hi Select I...
Страница 41: ...sent to main memory at once 8 Write Protect Write Saved settings is ingnored 8 Write Back Writes are cached but not sent to main memory until necessary Default 4 Cache Extended Memory Area Controls ca...
Страница 42: ...gure serial prot B by using this option 8Disabled Disable the configuration 8Enabled Enable the configuration 8Auto BIOS or O S will select the configuration automatically Figure 2 4 I O Configuration...
Страница 43: ...y Set the base I O address to 370 377 CUSB Host Controller This option allows user to enable USB host controller 8Enable Enable USB host controller Default Value 8Disabled Disable this function COnboa...
Страница 44: ...g Select Menu Enter Select4Sub Menu F10 Save Exit Console Redirection CConsole Redirection This option allow user to remote monitoring and controlling the BIOS by client computer 4 COM Port Address Se...
Страница 45: ...aud rate at 57 6K 8115 2K Enable the specific baud rate at 115 2K 4 Console Type Enable the specified Cosole Type 8Options PC ANSI 7bit Default VT100 VT100 8bit VT100F VT U TF8 4 Flow Control Enable t...
Страница 46: ...Enable Console Redirection after O S has loaded 8On Continue C R after Power on Self Test 8Off Disable this function Default 4 of Vedio pages to support This isthe number ofvedio pages to allocate fo...
Страница 47: ...upervisor or user passwords or both for different level of password securities In addition user also can set the virus protection for boot sector CSet User Password You can only enter but do not have...
Страница 48: ...ystem on boot 8Disabled Disable this function Default CFixeddisk boot sector 8Write Protect Write protects boot sector on harddisk to protect against virus 8Normal Set the fixed disk boot sector at No...
Страница 49: ...ted using the up and down arrow keys By applying and Space key you can promote devices and by using the key you can demote devices Promotion or demotion of devices alerts the priority that the system...
Страница 50: ...es in theBIOS setup you shouldsave yourchnages and exit BIOS setup program Select Exit from the menu bar to display the following sub menu E Exit Saving Changes E Exit Discarding Changes E Load Settup...
Страница 51: ...on dialog box with a message as below CDiscard Changes This option allow s user to load previos values from CMOS for all setup item When you press Enter on this item you will get a confirmation dialog...
Страница 52: ...IMM CNR Communication and Networking Riser DMA Direct Memory Access DMI Desktop Management Interface DIMM Dual Inline Memory Module DRM Dual Retention Mechanism DRAM Dynamic Random Access Memory DDR D...
Страница 53: ...y Translator Hub MPT Memory Protocol Translator NIC Network Interface Card OS Operating System OEM Original Equipment Manufacturer PAC PCI A G P Controller POST Power On Self Test PCI Peripheral Compo...