background image

BIOS Setup

- 97 -

5-2-19 

VLAN Configuration

Parameter

Description

Enter Configuration Menu

Press [Enter] to configure advanced items.

 

Š

Create new VLAN

 

Š

VLAN ID

 

– Sets VLAN ID for a new VLAN or an existing VLAN.

 

– Press the <+> / <-> keys to increase or decrease the desired values.

 

– The valid range is from 0 to 4094.

 

Š

Priority

 

– Sets 802.1Q Priority for a new VLAN or an existing VLAN.

 

– Press the <+> / <-> keys to increase or decrease the desired values.

 

– The valid range is from 0 to 7.

 

Š

Add VLAN

 

– Press [Enter] to create a new VLAN or update an existing VLAN.

 

Š

Configured VLAN List

 

Š

Remove VLAN

 

– Press [Enter] to remove an existing VLAN.

Содержание R283-Z91-AAD1

Страница 1: ...83 Z91 AAD2 R283 Z91 AAV1 R283 Z91 AAV2 AMD EPYC 9004 Server System 2U DP 12 2 Bay NVMe SATA SAS with expander AAD1 AAV1 AMD EPYC 9004 Server System 2U DP 12 2 Bay SATA SAS with expander AAD2 AAV2 Use...

Страница 2: ...and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short...

Страница 3: ...his user s guide NOTE Pieces of additional information related to the current topic CAUTION Precautionary measures to avoid possible hardware or software problems WARNING Alerts to any damage that mig...

Страница 4: ...of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous mov...

Страница 5: ...stem is removed from the rack before opening the chassis adding or removing any non hot plug components Hazardous conditions devices and cables Hazardous electrical conditions may be present on power...

Страница 6: ...do not have such a tab take care when us ing needle nosed pliers to remove or install a jumper grip the narrow sides of the jumper with the pliers never the wide sides Gripping the wide sides can dam...

Страница 7: ...g the Hard Disk Drive 32 3 3 Removing and Installing the Fan Duct 34 3 4 Removing and Installing the Heat Sink 35 3 5 Removing and Installing the CPU 36 3 6 Removing and Installing Memory 38 3 6 1 Twe...

Страница 8: ...iguration 82 5 2 8 PCI Subsystem Settings 83 5 2 9 USB Configuration 85 5 2 10 Network Stack Configuration 87 5 2 11 NVMe Configuration 88 5 2 12 SATA Configuration 89 5 2 13 Graphic Output Configurat...

Страница 9: ...5 6 Server Management Menu 164 5 6 1 System Event Log 166 5 6 2 View FRU Information 167 5 6 3 BMC Network Configuration 168 5 6 4 IPv6 BMC Network Configuration 169 5 7 Security Menu 170 5 7 1 Secur...

Страница 10: ...10 This page intentionally left blank...

Страница 11: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 12: ...ocket 2 x LGA 6096 Socket SP5 Socket Socket Security Secur i t y Ser ver Oper ating P r oper t i es PowerSuppl y Chipset System on Chip Memory 24 x DIMM slots DDR5 memory supported only 12 Channel mem...

Страница 13: ...e connected to SAS expander c Please select enterprise SATA devices for SAS expander system AAD2 12 x 3 5 2 5 SATA SAS hot swappable bays 2 x 2 5 SATA SAS hot swappable bays in rear side Broadcom SAS3...

Страница 14: ...slot Gen5 x8 FHHL from CPU_1 Riser Card CRS202N 1 x PCIe x16 slot Gen5 x16 FHHL from CPU_1 1 x PCIe x16 slot Gen5 x8 FHHL from CPU_1 2 x OCP 3 0 slots with PCIe Gen5 x16 bandwidth 1 x from CPU_0 and 1...

Страница 15: ...Card CRS202N 2 x PCIe x16 slots Gen5 x16 FHHL from CPU_1 2 x OCP 3 0 slots with PCIe Gen5 x16 bandwidth 1 x from CPU_0 and 1 x from CPU_1 Supported NCSI function 1 x M 2 slot M key PCIe Gen3 x4 from C...

Страница 16: ...button with LED Backplane I O AAD1 Front Side Backplane P N 9CBP21C1NR 00 Rear Side Backplane P N 9CBP2022NR 00 Speed and bandwidth PCIe Gen4 x4 or SATA 6Gb s or SAS 12Gb s in front side SATA 6Gb s or...

Страница 17: ...120V 12A 50 60Hz 200 240V 10A 50 60Hz DC Output Max 1000W 100 120V 12V 81 5A 12Vsb 2 5A Max 1600W 200 240V or 240Vdc Input 12V 133A 12Vsb 2 5A AAV1 AAV2 Dual 1600W 240V 80 PLUS Titanium redundant pow...

Страница 18: ...Inventory Fan Profile System Firewall Power Consumption Power Control LDAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirectio...

Страница 19: ...DIMMs Speed up to 4800 MHz PCIe4 0 x16 PCIe 5 0 x16 FHHL slot PCIe 5 0 x8 FHHL slot PCIe5 0 x16 PCIe5 0 x16 PCIe5 0 x16 PCIe 5 0 x16 FHHL slot Riser CRS101T PCIe5 0 x16 PCIe 5 0 x8 FHHL slot PCIe 5 0...

Страница 20: ...12 x DIMMs Speed up to 4800 MHz PCIe 5 0 x16 FHHL slot PCIe 5 0 x16 FHHL slot PCIe5 0 x16 PCIe5 0 x16 PCIe5 0 x16 PCIe 5 0 x16 FHHL slot Riser CRS101T PCIe5 0 x16 PCIe 5 0 x16 FHHL slot PCIe 5 0 x16 F...

Страница 21: ...tion 1 Front Panel LEDs and Buttons 2 USB 3 2 Gen1 Port x 2 Note Drives with green latches support NVMe Refer to section 2 3 Front Panel LEDs and Buttons for a detailed description of the function of...

Страница 22: ...T12 SLOT11 SLOT7 SLOT4 SLOT1 No Description No Description 1 Mini DP Port 5 Server Management LAN Port 2 ID LED 6 OCP 3 0 Slot Option SFF 3 USB 3 2 Gen1 Port x 2 7 PCIe Slot 4 1GbE LAN Port x 2 8 2 5...

Страница 23: ...n ACPI S5 state power off System is in ACPI S4 state hibernate mode 4 ID Button with LED Note This LED represents the RoT function LED behavior Please see the following section for detail LED behavior...

Страница 24: ...r the server to generate a NMI to the processor If multiple bit ECC errors occur the server will effectively be halted 5 System Status LED Note Green On Indicates system is operating normally Amber On...

Страница 25: ...ges OFF OFF Recovering BMC Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Recovering BIOS Active Flash Blinks Blue 4 times per second Blinks Green 4 times per second Authe...

Страница 26: ...r Microchip CEC1702 Once Microchip CEC1702 is working Auth or recovery the front panel LED is controlled by Microchip CEC1702 and vice versa Active Flash Authentication AUTH Fail BMC AUTH Fail Note2 B...

Страница 27: ...Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or rec...

Страница 28: ...Green Blinking Power supply firmware updateing mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut...

Страница 29: ...FF OFF OFF Removed HDD Slot LED on Back Panel Green ON 1 OFF Amber OFF OFF RAID configuration via HW RAID Card or SW RAID Card Disk LED Green ON OFF BLINK 2 OFF Amber OFF ON Low Speed 2 Hz OFF OFF Rem...

Страница 30: ...er you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare me...

Страница 31: ...AC power Follow these instructions to remove the chassis cover 1 Remove the screw securing the chassis cover 2 Unlock the plastic handle and pull the grip handle to open the panel cover 3 Slide the c...

Страница 32: ...is connected to the connector on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the directio...

Страница 33: ...s the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the HDD tray 4 Align the hard disk drive with the positioning screw on the HDD tray 5 Secu...

Страница 34: ...and Installing the Fan Duct Follow these instructions to remove the fan duct 1 Lift up to remove the fan duct 2 To reinstall the fan duct align the fan duct with the guiding groove Push down the fan...

Страница 35: ...ace Open the system according to the instructions WARNING Failure to turn off the server before you start installing components may cause serious damage Do not attempt the procedures described in the...

Страница 36: ...s described in the following sections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover 2 Flip open th...

Страница 37: ...rew When installing the heatsink to CPU use a Torx T20 screwdriver to tighten 6 captive nuts in sequence as 1 6 The screw tightening torque 13 5 0 5 kgf cm To ensure the system operates properly make...

Страница 38: ...0_I0 DIMM_P0_L0 DIMM_P1_R0 DIMM_P1_Q0 DIMM_P1_N0 DIMM_P1_O0 DIMM_P1_P0 DIMM_P1_M0 DIMM_P1_S0 DIMM_P1_T0 DIMM_P1_W0 DIMM_P1_V0 DIMM_P1_U0 DIMM_P1_X0 Read the following guidelines before you begin to in...

Страница 39: ...lly into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2...

Страница 40: ...S2R 4 Ranks 4800 2S4R 8 Ranks 4800 2S8Rx4 16 ranks 4800 EPYC Memory Speed based on DIMM Population Two DIMM per Channel 14 layer 93mil high Dk PCB stackup DIMM Type DIMM Population Max EPYC 9004 DDR5...

Страница 41: ...EPYC 9004 DDR5 Frequency MT s DIMM 0 DIMM 1 RDIMM 1R 4800 1R 1R 4400 2R 4800 1R 2R 4000 2R 2R 4000 3DS 2S2R 4 Ranks 4800 2S4R 8 Ranks 4800 2S8R 16 Ranks 4800 2S2R 4 Ranks 2S2R 4 Ranks 4000 2S4R 8 Ran...

Страница 42: ...nclude a riser card or any cabling as standard To install a PCIe card a riser card must be installed Follow these instructions to install a PCIe card 1 Loosen the two thumbnail screws securing the ris...

Страница 43: ...43 System Hardware Installation 2 2 1 1 3 2 4 5 3 2 4 5...

Страница 44: ...latch Follow these instructions to install an OCP 3 0 Mezzanine card 1 Remove the two screws securing the OCP 3 0 card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 card into...

Страница 45: ...NG Please ensure a heatsink is attached to any M 2 device installed into the system Installing an M 2 device without any heatsink may result in the system overheating or system performance being throt...

Страница 46: ...previous steps to install the replacement fan assembly 1 2 Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch i...

Страница 47: ...power supply handle 2 Press the retaining clip on the right side of the power supply unit in the direction indicated 3 Pull out the power supply unit using the handle 4 Insert the replacement power su...

Страница 48: ...e Installation 3 12 Cable Routing 3 12 1 R283 Z91 AAD1 CPU1 CPU0 A A B B A Front Panel LEDs and Buttons Cable Motherboard FP_1 Front IO Board FP_1 Front IO Board FP_1 B Front Panel USB 3 Ports Cable M...

Страница 49: ...49 System Hardware Installation CPU1 CPU0 A A B B A HDD Backplane Board Signal Cable Motherboard BP_1 F HDD Board BP_1 B HDD Backplane Board Signal Cable F HDD Board BP_SERIES R HDD Board BP_1...

Страница 50: ...50 System Hardware Installation CPU1 CPU0 A B B A A HDD Backplane Board Power Cable Motherboard BP_ATX1 F HDD Board ATX1 B HDD Backplane Board Power Cable Motherboard BP_ATX2 R HDD Board BP_2X3...

Страница 51: ...Op on RAID Card A SATA Cable Optional RAID Card C NVMe 8 9 Cable Motherboard P0_MCIO_0 F HDD Board SAS_IN0 SAS_IN1 F HDD Board U 2 0 U 2 1 B SATA Cable R HDD Board SL_SAS0 D NVMe 10 11 Cable Motherboa...

Страница 52: ...52 System Hardware Installation CPU1 CPU0 A A B B A Riser Card Cable Motherboard P1_MCIO_0 Motherboard Slot SLOT4 B Riser Card Cable Motherboard P1_MCIO_1 Motherboard Slot SLOT1...

Страница 53: ...53 System Hardware Installation CPU1 CPU0 A B A B A XGMI CPU1 Cable Motherboard MCIO_G1_0 Motherboard MCIO_G0_1 B XGMI CPU0 Cable Motherboard MCIO_G1_1 Motherboard MCIO_G0_0...

Страница 54: ...em Hardware Installation 3 12 2 R283 Z91 AAD2 CPU1 CPU0 A A B B A Front Panel LEDs and Buttons Cable Motherboard FP_1 Front IO Board FP_1 Front IO Board FP_1 B Front Panel USB 3 Ports Cable Motherboar...

Страница 55: ...55 System Hardware Installation CPU1 CPU0 A A B B A HDD Backplane Board Signal Cable Motherboard BP_1 F HDD Board BP_1 B HDD Backplane Board Signal Cable F HDD Board BP_SERIES R HDD Board BP_1...

Страница 56: ...56 System Hardware Installation CPU1 CPU0 A B B A A HDD Backplane Board Power Cable Motherboard BP_ATX1 F HDD Board ATX1 B HDD Backplane Board Power Cable Motherboard BP_ATX2 R HDD Board BP_2X3...

Страница 57: ...57 System Hardware Installation CPU1 CPU0 A A B B Op on RAID Card A SATA Cable Optional RAID Card F HDD Board SAS_IN1 B SATA Cable R HDD Board SL_SAS0 F HDD SL_SAS0...

Страница 58: ...58 System Hardware Installation CPU1 CPU0 A B A B A XGMI CPU1 Cable Motherboard MCIO_G1_0 Motherboard MCIO_G0_1 B XGMI CPU0 Cable Motherboard MCIO_G1_1 Motherboard MCIO_G0_0...

Страница 59: ...en3 x2 Supports NGFF 22110 5 MCIO Connector MCIO_G1_0 1 6 MCIO Connector MCIO_G0_0 1 7 M 2 Slot PCIe Gen3 x4 Supports NGFF 22110 8 HDD Backplane Board Connector 9 Front Panel Connector 10 Front Panel...

Страница 60: ...Pin ATX Backplane Power Connector 24 MCIO Connector P1_MCIO_0 1 25 M 2 Slot PCIe Gen3 x4 NGFF 22110 Supports heatsink 26 G SC Module Connector 27 OCP 3 0 Connector PCIe Gen5 x16 28 Riser Connector 3 P...

Страница 61: ...Sw ch Onboard LAN SW 1 OFF NCSI_SW ON OFF Slot 2 OCP3 0 G SC MB ON ON Slot 1 OCP3 0 Clear CMOS CLR_CMOS Enable Default 1 2 3 J1 ON OFF 1 HOST_SMBUS_SEL BIOS defined 2 Reserved Reserved 3 BIOS_PWD Cle...

Страница 62: ...d Components 62 4 3 G SC Module 4 3 1 CDCR112 BMC1 BMC2 BIOS1 BIOS2 1 2 3 4 5 Item Description 1 10 100 1000 Server Management LAN Port 2 1GbE LAN Port 2 3 1GbE LAN Port 1 4 USB 3 2 Gen1 Port x 2 5 Mi...

Страница 63: ...tem Description 1 SlimLine SAS Connector SFF 8654 4i SAS_IN0 2 SlimLine SAS Connector SFF 8654 4i SAS_IN1 3 SlimLine SAS Connector SFF 8654 4i SL_SAS0 4 SlimLine SAS Connector SFF 8654 4i U 2 1 5 Slim...

Страница 64: ...d Components 64 4 4 2 CBP2022 Rear System Storage Board 2 3 1 Item Description 1 SlimLine SAS Connector SFF 8654 4i U_2_0 2 SlimLine SAS Connector SFF 8654 4i U_2_1 3 SlimLine SAS Connector SFF 8654 4...

Страница 65: ...with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected re...

Страница 66: ...the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to...

Страница 67: ...displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen H...

Страница 68: ...mation CPU Brand String CPU Speed Processor Core Microcode Patch Displays the technical specifications for the installed processor s Total Memory Note2 Displays the total memory size of the installed...

Страница 69: ...ter Description Onboard LAN Information LAN1 MAC Address Note Displays LAN MAC address information LAN2 MAC Address Note Displays LAN MAC address information System Date Sets the date following the we...

Страница 70: ...enu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Se...

Страница 71: ...BIOS Setup 71 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section...

Страница 72: ...e BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Disable Enable Default setting is Enable SPI TPM Suppor...

Страница 73: ...BIOS Setup 73 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable...

Страница 74: ...on OnBrd Ext VGA Select Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Auto Note This configurable option will be displayed when Boot Mode S...

Страница 75: ...2 4 AST2600 Super IO Configuration Parameter Description AST2600 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration o...

Страница 76: ...for the serial port Options available Disabled Enabled Default setting is Enabled Devices Settings Displays the Serial Port 1 device settings Change Settings Select an optimal settings for Super IO D...

Страница 77: ...gs Parameter Description Wake System from S5 Enable Disable system wake on alarm event Options available Disabled Fixed Time Dynamic Time When Fixed Time is selected system will wake on the hr min sec...

Страница 78: ...1 Serial Over LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN Console Redirection is set to Enabled Termin...

Страница 79: ...1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a...

Страница 80: ...EMS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Disabled Enabled Default...

Страница 81: ...a loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the fl...

Страница 82: ...onfiguration Parameter Description SVM Mode Enable Disable the CPU Virtualization Options available Disabled Enabled Default setting is Enabled CPU 0 1 Information Press Enter to view the memory infor...

Страница 83: ...BIOS Setup 83 5 2 8 PCI Subsystem Settings...

Страница 84: ...zzanine OCP max link speed Options available Auto Gen5 Gen4 Gen3 Gen2 Gen1 Default setting is Auto Onboard LAN Controller Note3 Enable Disable the onboard LAN devices Options available Disabled Enable...

Страница 85: ...B devices are connected DISABLE option will keep USB devices available only for EFI applications Options available Enabled Disabled Auto Default setting is Enabled XHCI Hand off Enable Disable the XHC...

Страница 86: ...ult setting is 20 sec Device power up delay Maximum time the device will take before it properly reports itself to the Host Controller Auto uses default value for a Root port it is 100 ms for a Hub po...

Страница 87: ...he Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enab...

Страница 88: ...nfiguration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe LED Control Enable Disable NVMe LED Control Options available System Default Disabled Enable...

Страница 89: ...BIOS Setup 89 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type...

Страница 90: ...13 Graphic Output Configuration Parameter Description Output Device Type Selects output device type Options available First loaded Device Onboard Device External Device Specific Device Default setting...

Страница 91: ...BIOS Setup 91 5 2 14 AMD Mem Configuration Status Parameter Description CPU 0 1 Press Enter to view the memory configuration status related to CPU 0 1...

Страница 92: ...guration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit...

Страница 93: ...isk Options available Boot Service Data Reserved Default setting is Boot Service Data Create Raw Creates a raw RAM disk Size Hex Input a valid RAM disk size that should be multiple of the RAM disk blo...

Страница 94: ...nitiator Name Press Enter and name iSCSI Initiator Only IQN format is accepted Range from 4 to 223 Add an Attempt Press Enter to configure advanced items Delete Attempts Press Enter to configure advan...

Страница 95: ...BIOS Setup 95 5 2 18 Intel R I350 Gigabit Network Connection...

Страница 96: ...Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network...

Страница 97: ...VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decreas...

Страница 98: ...te Options available Enabled Disabled Default setting is Disabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gatewa...

Страница 99: ...or the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor solicitation messages sent while performing Duplicate Address Detection on a...

Страница 100: ...100 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related sub...

Страница 101: ...BIOS Setup 101 5 3 1 CPU Common Options...

Страница 102: ...Control Options available Low Current Idle Typical Current Idle Auto Default setting is Auto SEV ES ASID Space Limit Configures the Space limit for SEV ES ASIDs Default setting is 1 SEV Control Enabl...

Страница 103: ...e Disable AVX512 Options available Disabled Enabled Auto Default setting is Auto MONITOR and MWAIT disable The MONITOR MWAIT MONITORX and MWAITX opcodes become invalid when enabled Options available E...

Страница 104: ...you can control the number of CCDs to be used and the number of cores to be used CCD Control Options available Auto 2 CCDs 4 CCDs 6 CCDs 8 CCDs 10 CCDs Default setting is Auto Core Control Options ava...

Страница 105: ...cess history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Enable Disable L1 Region Prefetcher Options available Disable Enable Aut...

Страница 106: ...Disabled Enabled Auto Default setting is Auto Core Watchdog Timer Interval Select the CPU Watchdog Timer interval Options available 2 681s 1 340s 669 41ms 334 05ms 166 37ms 82 53ms 40 61ms 20 970ms 1...

Страница 107: ...ternal IP sync flood propagation Enable Disable SyncFlood to UMC downstream slaves Options available Sync flood disabled Sync flood enabled Auto Default setting is Auto Sync flood propagation to DF Co...

Страница 108: ...nfiguration NPS and interleaving selection and may not always be possible Options available Do not remap Attempt to remap Auto Default setting is Auto DRAM map inversion Enable Disable the DRAM map in...

Страница 109: ...Options available Disabled Enabled Auto Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Manual Auto Default setting is Auto ACPI SLI...

Страница 110: ...Gbps 27Gbps 30Gbps 32Gbps Auto Default setting is Auto 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available 12Gbps 16Gbps 17Gbps 18Gbps 20Gbps 22Gbps 23Gbps 24Gbps 25Gbps 26G...

Страница 111: ...to configure the xGMI TXEQ Search Mask CPU0 1 link xGMI AC DC Coupled Link Press Enter to configure the xGMI AC DC Coupled link xGMI AC DC Coupled Link Control Note Options available Manual Auto Defau...

Страница 112: ...I Parameter Description SDCI Note Options available Disabled Enabled Auto Default setting is Auto DisRmSteer Options available Disabled Enabled Auto Default setting is Auto Note Advanced items prompt...

Страница 113: ...advanced items DDR RAS Press Enter for configuration of advanced items DDR Bus Configuration Press Enter for configuration of advanced items DDR Timing Configuration Press Enter for configuration of a...

Страница 114: ...ilable Enabled Disabled Auto Default setting is Auto Address Hash CS Enable or disable CS addressing hashing Options available Enabled Disabled Auto Default setting is Auto Address Hash Rm Enable or d...

Страница 115: ...ameter Description DDR Cotroller Configuration DDR Power Options Press Enter for configuration of advanced items Memory Channel Disable Press Enter for configuration of advanced items Refresh Manageme...

Страница 116: ...Sub Urgent Refresh Lower Bound Specifies the stored refresh limit required to enter sub urgent refresh mode Urgent Refresh Limit Specifies the stored refresh limit required to enter urgent refresh mod...

Страница 117: ...BIOS Setup 117 5 3 3 2 2 Memory Channel Disable Parameter Description Memory Channel Disable Memory Channel Disable Bitmask CPU0 CPU1 Channel_ Press Enter to enable disable specific memory channel...

Страница 118: ...d Override Rolling Accumulated ACT Initial Management Threshold Options available 32 40 48 56 64 72 80 Auto Default setting is Auto RAA Maximum Management Threshold Override Rolling Accumulated ACT Ma...

Страница 119: ...MBIST Aggressors Note1 Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note1 Enable Disable to report 2D data eye...

Страница 120: ...disable PMU Mem BIST Algorithm DDR Healing BIST Repair Type Note2 For DRAM errors found in the BIOS memory BIST select the repair type Options available Soft Repair Hard Repair No Rrepairs Test only...

Страница 121: ...available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane...

Страница 122: ...ranularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options availabl...

Страница 123: ...Disable Default setting is Disable RCD Parity Enable Disable the RCD Parity function Options available Auto Enabled Disabled Default setting is Enabled Max RCD Parity Error Replay Default setting is 8...

Страница 124: ...ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Disabled Max DR...

Страница 125: ...t Mode Code Word Count Mode Default setting is Auto DRAM AutoEcs during Self Refresh Options available Auto AutoEcs Disabled AutoEcs Enabled Default setting is Auto DRAM ECS WriteBack Suppression Opti...

Страница 126: ...RZQ 6 40 RZQ 7 34 Default setting is Auto Dram ODT impedance RTT_ WR Select the DRAMs On die Termination impedance for RTT_WR Options available Auto RTT_OFF RZQ 240 RZQ 2 120 RZQ 3 80 RZQ 4 60 RZQ 5...

Страница 127: ...m 240 ohm 160 ohm 120 ohm 96 ohm 80 ohm 68 6 ohm 60 ohm 53 3 ohm 48 ohm 43 6 ohm 40 ohm 36 9 ohm 34 3 ohm 32 ohm 30 ohm 28 2 ohm 26 7 ohm 25 3 ohm Default setting is Auto Dram DQ drive strengths Selec...

Страница 128: ...y Timing Settings Options available Auto Enabled Default setting is Auto Memory Target Speed Specifies the memory target speed in MT s Options available Auto DDR3200 DDR3600 DDR4000 DDR4400 DDR4800 DD...

Страница 129: ...Training Options Parameter Description DDR Training Options DRAM PDA Enumerate ID Programming Specify PDA enumeration mode Options available Auto Toggling PDA enumeration mode Legacy PDA enumeration m...

Страница 130: ...Enabled Disabled Default setting is Auto AES Options available AES 128 AES 256 Default setting is AES 256 Data Scramble Enable Disable Data Scrambling Options available Enabled Disabled Default setti...

Страница 131: ...True Default setting is Auto PMIC Operation Mode Options available Secure Mode Programmable Mode Default setting is Programmable Mode PMIC Fault Recovery Options available Always Never Once Default s...

Страница 132: ...BIOS Setup 132 5 3 3 10 DDR Miscellaneous Parameter Description DDR Miscellaneous DRAM Survives Warm Reset Options available Enabled Disabled Default setting is Enabled...

Страница 133: ...BIOS Setup 133 5 3 4 NBIO Common Options...

Страница 134: ...e for each downstream port Options available Disable Enable Auto Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available...

Страница 135: ...sable Enable Default setting is Auto SRIS Options available Auto Disable Enable Default setting is Auto Multi Upstream Auto Speed Change Defines the setting of this feature for all PCIe devices Option...

Страница 136: ...DIS Options available 0 1 Auto Default setting is Auto Power Profile Selection Options available High Performace Mode Efficiency Mode Maximum IO Performance Mode Default setting is High Performace Mod...

Страница 137: ...to Manual Default setting is Auto 3D V Cache Options available Auto Disable 1 stack 2 stack 4 stack Default setting is Auto Diagnostic Mode Options available Disabled Enabled Auto Default setting is A...

Страница 138: ...f 0 indicates LOW severity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Enabled Disabled Auto Default setting is Auto NBIO SyncFlood R...

Страница 139: ...er Reporting Mechanism Selects the method of reporting AER errors from PCI Express Options available Firmware First Firmware Frist but allow OS First OS First Auto Default setting is Auto Edpc Control...

Страница 140: ...s Auto ACS Options available Auto Disable Enable Default setting is Auto ATS Options available Auto Disable Enable Default setting is Auto PASID Options available Auto Disable Enable Default setting i...

Страница 141: ...Enable Default setting is Auto P2PEgressStrap5 Options available Auto Disable Enable Default setting is Auto DirectTranslatedStrap5 Options available Auto Disable Enable Default setting is Auto SsidE...

Страница 142: ...BIOS Setup 142 Parameter Description RCC_DEV0 continued EXTENDED_FMT Options available Auto Disable Enable Default setting is Auto...

Страница 143: ...ms USB Configuration Options Press Enter for configuration of advanced items AC Power Loss Options Press Enter for configuration of advanced items Uart Configuration Options Press Enter for configurat...

Страница 144: ...ns available Disabled Enabled Auto Default setting is Auto Release SPD Host Control Options available Disabled Enabled Auto Default setting is Auto I2C SDA Hold Override Options available Disabled Ena...

Страница 145: ...efault setting is Auto SATA Staggered Spin up Options available Disabled Enabled Auto Default setting is Auto SATA Disabled AHCI Prefetch Function Options available Disabled Enabled Auto Default setti...

Страница 146: ...nable Disable USB controller Options available Enabled Disabled Auto Default setting is Auto USB ecc SMI Enable Options available Enable Off Auto Default setting is Auto MCM USB enable Press Enter for...

Страница 147: ...p 147 5 3 5 4 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is La...

Страница 148: ...BIOS Setup 148 5 3 5 5 Uart Configuration Options Parameter Description Uart Configuration Options Uart 0 1 2 3 Enable Options available Disabled Enabled Auto Default setting is Auto...

Страница 149: ...BIOS Setup 149 5 3 5 6 ESPI Configuration Options Parameter Description ESPI Configuration Options ESPI Enable Options available Disabled Enabled Auto Default setting is Auto...

Страница 150: ...ALink RAS Support Enable Disable the ALink RAS Support Options available Disabled Enabled Auto Default setting is Auto Reset after sync flood Enables AB to forward downstream sync flood message to sys...

Страница 151: ...BIOS Setup 151 5 3 5 8 Miscellaneous Options Parameter Description Miscellaneous Options Boot Timer Enable Enable Disable Boot Timer Options available Disabled Enabled Auto Default setting is Auto...

Страница 152: ...on Options Socket 0 P0 P2 NTB Enable Enable Disable NTB on Socket 0 P0 P2 Link Options available Auto Enable Disable Default setting is Auto Socket 0 G0 G2 NTB Enable Enable Disable NTB on Socket 0 G0...

Страница 153: ...BL Basic Console Out Control Enable Disable the Basic ConsoleOut function for ABL Options available Disable Enable Auto Default setting is Auto ABL PMU message Control To Control the total number of P...

Страница 154: ...back FAR Press Enter for configuration of advanced items FAR enforcement state Default setting is Enabled SPL value in the CPU Fuse SPL value in the SPL table FAR Switch Options available Disabled Ena...

Страница 155: ...nsive Storgae IO Intensive NIC Throughput Intensive NIC Latency Sensitive Accelerator Throughput VMware vSphere Optimized Linux KVM Optimized Container Optimized RDBMS Optimized Big Data Analytics Opt...

Страница 156: ...ailable Auto Enabled Disabled Default setting is Auto CXL vLSM Power Management Press Enter for configuration of advanced items CXL io L1 L2 Options available Auto Enabled Disabled Default setting is...

Страница 157: ...e function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description RAS Press Enter for configuration of advanced items SPI Locking Enable Disable S...

Страница 158: ...Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for unc...

Страница 159: ...orrected Error Mask register of PCIe device PCIe Device UnCorr Err Sev Reg Initialize the PCIe AER Uncorrected Error Severity register of PCIe device DRAM Hard Post Package Repair This feature allows...

Страница 160: ...rameter Description PCIe Link Training Type Options available 1 Step 2 Step Default setting is 1 Step PCIe Compliance Mode Options available Off On Default setting is Off Program All VR Enable Disable...

Страница 161: ...61 5 5 1 North Bridge Parameter Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU 0 1 Information Press Enter to view information related...

Страница 162: ...BIOS Setup 162 5 5 2 Fabric Resource...

Страница 163: ...CPU 0 1 NBIO_ PCIe Bus Number Prefetchable Mmio Above 4G size Change CPU 0 1 NBIO_ Prefetchable MMIO Above 4G Size Options available System Default 0 1G 2G 4G 8G 16G 32G 64G 128G 256G 512G 1T 2T 4T 8T...

Страница 164: ...OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Note Configures OS Watchdog Timer Options available 5 mi...

Страница 165: ...ent Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configur...

Страница 166: ...se SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do N...

Страница 167: ...Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends...

Страница 168: ...P address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays...

Страница 169: ...network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by...

Страница 170: ...l settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user...

Страница 171: ...booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Stan...

Страница 172: ...ys the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Update Append Authorized Signatures DB Displ...

Страница 173: ...lues Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Enabled Dis...

Страница 174: ...re the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Ent...

Страница 175: ...e so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of r...

Страница 176: ...corrupt the boot block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Copy the XXX rom to USB diskette 2 Set...

Страница 177: ...was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 11 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Ar...

Отзывы: