- 21 -
System Appearance
BIOS : AUTH fail
(Note2)
Blinks Blue
1 time per
second
Blinks Amber
1 time per second
BMC : AUTH fail after doing recovery
(Note3)
Blinks Blue
2 times per
second
[ON OFF OFF]
Blinks Green
2 times per
second
[ON OFF OFF]
BIOS : AUTH fail after doing recovery
(Note3)
Blinks Blue
2 times per
second
[ON OFF OFF]
Blinks Amber
2 times per
second
[ON OFF OFF]
Backup Flash Authentication Fail
(Note4)
BMC : AUTH fail
Blinks Blue
2 times per
second
[ON OFF
ON OFF]
Blinks Green
2 times per
second
[ON OFF
ON OFF]
BIOS : AUTH fail
Blinks Blue
2 times per
second
[ON OFF
ON OFF]
Blinks Amber
2 times per
second
[ON OFF
ON OFF]
NOTE!
1. EC FW is broken or not exited result in Microchip CEC1702 cannot load EC FW for authentication.
2 (1) Authentication fail include below scenarios
Configuration table is missing or modified
Public key is missing or modified
Protected area or signature is modified
Flash empty
3. If active flash is still authentication failed after recovery sequence, Microchip CEC1702 stop the process
and showing LED behavior.
4. If backup flash authentication is failed cause by configuration table, public key or protected area is
broken. Microchip CEC1702 stop the process and showing LED behavior.
5. Front panel LED is controlled by BMC or Microchip CEC1702. Once Microchip CEC1702 is working(Auth
or recovery), the front panel LED is controlled by Microchip CEC1702 and vice versa.
Содержание R162-ZA1
Страница 1: ...R162 ZA1 AMD EPYC 7002 UP Server System User Manual Rev 1 0 ...
Страница 10: ... 10 This page left intentionally blank ...
Страница 16: ...Hardware Installation 16 1 3 System Block Diagram ...
Страница 43: ... 43 System Hardware Installation Front HDD Backplane Board Power Cable Front HDD Backplane Board Signal Cable ...
Страница 44: ...System Hardware Installation 44 ATX Power Cable ...
Страница 45: ... 45 System Hardware Installation Control Signal Power Cable Slimline SAS to SATA Cable 0 1 ...
Страница 46: ...System Hardware Installation 46 Slimline SAS to NVMe Card 0 1 Slimline SAS to NVMe Card 2 3 ...
Страница 47: ... 47 System Hardware Installation This page intentionally left blank ...
Страница 51: ... 51 Motherboard Components This page left intentionally blank ...
Страница 71: ... 71 BIOS Setup 5 2 9 PCI Subsystem Settings ...
Страница 82: ...BIOS Setup 82 5 2 18 Intel R I350 Gigabit Network Connection ...
Страница 84: ...BIOS Setup 84 5 2 19 VLAN Configuration ...
Страница 87: ... 87 BIOS Setup 5 2 21 MAC IPv6 Network Configuration ...