BIOS Setup

5-7  Boot Manager

The Boot manager menu allows you to specify the boot-up drive. BIOS setup will display an error message if 

the legacy drive(s) specified is not bootable. 

  

Boot Override

  

UEFI: Built-in EFI Shell 

  

 

Press Enter to configure the device as the boot-up drive.  

Содержание GS-R12P4G

Страница 1: ...GS R12P4G GS R12P8G Dual LGA2011 sockets motherboard for Intel Xeon series processors Service Guide Rev 1 0...

Страница 2: ...this manual may be made by GIGABYTE without prior notice No part of this manual may be reproduced copied translated transmitted or published in any form or by any means without GIGABYTE s prior writte...

Страница 3: ...NOT be covered in this generic service guide In suchcases please contact your regional offices or the responsible personnel channel to provide youwith further technical details 2 Please note WHEN ORDE...

Страница 4: ...on 18 2 5 2 Installing a Memory 19 2 5 3 DIMM Population Table 19 2 6 Installing the PCI Expansion Card 20 2 7 Installing the Hard Disk Drive 21 2 7 1 GS R12P4G Hard Disk Drive Installation 21 2 7 1 G...

Страница 5: ...uper IO Configuration 52 5 2 7 Serial Port Console Redirection 54 5 3 Chipset Menu 56 5 3 1 North Bridge Configuration 57 5 3 1 1 IOH Configuration 59 5 3 1 2 DIMM Information 61 5 3 2 South Bridge Co...

Страница 6: ...R12P8G Driver CD The box contents above are for reference only and the actual items shall depend on the product package you obtain The box contents are subject to change without notice The motherboard...

Страница 7: ...not block or cover these openings Make sure youprovide adequate space around the system for ventilation when you set up your work area Never insertobjects of any kind into the ventilation openings To...

Страница 8: ...undesired opera tion Canadian Department of Communications Compliance Statement This digital apparatus does not exceed the Class A limits for radio noise emissions from digitalapparatus as set out in...

Страница 9: ...e waste collection centers for activation of the treatment collection recycling and disposal procedure The separate collection and recycling of your waste equipment at the time of disposal will help t...

Страница 10: ...dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before...

Страница 11: ...port Expansion Slot 2 x PCI Express x8 slots Onboard Graphics ASPEED AST2300 supports 16MB VRAM Mass Storage GS R12P4G 4 x 3 5 Hot Swap SATA HDDs Support for Intel IRST SATA RAID 0 RAID 1 RAID 5 RAID...

Страница 12: ...tus LED I O Controller ASPEED AST2300 BMC chip Hardware Monitor System voltage detection CPU System temperature detection BIOS 1 x 64 Mbit flash AMI BIOS Environment Ambient Temperature Relative Humid...

Страница 13: ...both sides of the CPU and alignment keys on the CPU socket Apply an even and thin layer of thermal grease on the surface of the CPU Do not turn on the computer if the CPU cooler is not installed other...

Страница 14: ...not turned on or connected to AC power Follow these instructions to remove the system cover 1 Loosen and remove the thumbscrew securing the front chassis cover 2 Press the the indentation located at t...

Страница 15: ...Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the fan duct 2 To install the fan duct align the fan duct with the guiding groove Push down the fa...

Страница 16: ...unit on a flat and stable surface Open the system according to the instructions WARNING Failure to properly turn off the server before you start installing components may cause serious damage Do not a...

Страница 17: ...install the heat sinks 1 Apply thermal compound evenly on the top of the CPU Remove the protective cover from the underside of the heat sink 2 Place the heat sink s on top of the CPU 3 Tighten the fou...

Страница 18: ...imes of the original memory bandwidth The four DDR3 memory sockets are divided into four channels each channel has two memory sockets as following Channel 1 DDR3_P0_A0 DDR3_P0_A1 For pimary CPU DDR3_P...

Страница 19: ...sh it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 2 5 3 DIMM Population Table 1N 1N 1...

Страница 20: ...nal injury or damage to equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI...

Страница 21: ...ncorrectly Make sure that the HDD is connected to the HDD connector on the backplane 2 7 1 GS R12P4G Hard Disk Drive Installation Follow these instructions to install the Hard disk drive 1 Press the r...

Страница 22: ...to install the Hard disk drive 1 Press the release button 2 Pull the locking lever to remove the HDD tray 3 Slide hard disk into blank 4 Secure the hard drive to the tray with four 4 screws as shown D...

Страница 23: ...Installation 2 8 Replacing the FAN Assemblly Follow these instructions to replace the fan assembly 1 Lift up the fan assembly from the chassis 2 Reverse the previous step to install the replacement f...

Страница 24: ...wer supply 1 Disconnect the three power cables 2 Remove the four screws securing on the power supply 3 Lift the power supply out of the chassis in the direction of the arrow 4 Insert the replacement p...

Страница 25: ...P4G No Decription 1 HDD bays 2 Front Panel LEDs and buttons 3 Front USB 2 0 ports No Decription 1 HDD bays 2 Front Panel LEDs and buttons 3 Front USB 2 0 ports GS R12P8G 1 2 3 Please Go to Chapter 3 3...

Страница 26: ...o Decription 1 Power cord 2 Serial port 3 VGA port 4 RJ 45 LAN ports 3 top 4 buttom 5 RJ 45 LAN ports 1 Share NIC right 2 left 6 USB 2 0 ports 7 Server management LAN port 8 ID switch button 9 Low pro...

Страница 27: ...power applied to itor ACPI S0 state Green Blink System is in ACPI S1 state sleep mode N A Off System is not powered on or in ACPI S5 state power off System is in ACPI S4 state hlbernate mode 3 LAN1 L...

Страница 28: ...ge issue Non critical condition May indicate the following Redundant fan failure Redundant power module failure System temperature voltage issue HDD fault on RAID Chassis intrusion N A Off System not...

Страница 29: ...rate 2 Activity LED Green Blink Data transmission or receiving is occurring Green On No data transmission N A Off No data transmission or receiving is occuring 3 Connection Speed LED Green On Linking...

Страница 30: ...3 5 Hard Disk Drive LEDs 1 2 No Description Multi Color LEDs LED Active Green LED Active Amber 1 HDD Access Blink Off HDD Locate On Off HDD Failure Off On HDD connected and rebuilding data Blink Blin...

Страница 31: ...r 4 Motherboard Components 4 1 GA 7PESH4 Motherboard Components 1 2 3 4 5 6 7 8 9 12 13 14 11 15 16 17 18 19 20 21 22 23 24 25 26 10 27 28 29 31 30 32 33 34 35 36 37 59 57 55 56 54 38 49 50 51 52 53 3...

Страница 32: ...hannel 1 slot 1 for primary CPU 18 DDR3_P0_B0 Channel 2 slot 0 for primary CPU 19 DDR3_P0_B1 Channel 2 slot 1 for primary CPU 20 CPU0 Intel LGA2011 socket Primary CPU 21 BAT1 Battery socket 22 CPU0_FA...

Страница 33: ...ot 3 51 PCIE_3 PCI E slot 3 x16 slot Running at x8 shared bandwidth with PCI E slot 2 52 PCIE_4 PCI E slot 4 x16 slot 53 U56 BMC uopgrade ROM 54 BMC_LED1 BMC firmware readiness LED 55 J3 LAN4 link act...

Страница 34: ...ORD1 Skip Supervisor Password Jumper 1 2 Close Normal operation Default setting 2 3 Close Skip supervisor password 3 BMC_FRB1 Force to Stop FRB3 Timer Jumper 1 2 Close Normal operation Default setting...

Страница 35: ...Close Flash Descriptor Security in effect Default setting 8 S3_MASK S3 Power On Select Jumper 1 2 Close Stop an initial power on when BMC is not ready 2 3 Close Keep initial power on Default setting 9...

Страница 36: ...System fan connector 10 11 FAN11 System fan connector 11 12 FAN12 System fan connector 12 13 J4 Define HDD Type jumper 1 2 Close SAS 2 3 Close SATA 14 J3 SATA LSI SCU Switch jumper Please refer to th...

Страница 37: ...fan connector 11 12 FAN12 System fan connector 12 13 J4 Define HDD Type jumper 1 2 Close SAS 2 3 Close SATA 14 J3 SATA LSI SCU Switch jumper Please refer to the following table for jumper 15 J2 SATA L...

Страница 38: ...Hardware Installation 38 J2 J3 LSI SCU 2 3 Close 2 3 Close SATA 2 3 Close 1 2 Close J2 J3 Jumper Setting...

Страница 39: ...BIOS To flash the BIOS do it with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system insta...

Страница 40: ...ervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but...

Страница 41: ...isplayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen He...

Страница 42: ...Memory Information Total Memory Determines how much total memory is present during the POST System Date Set the date following the weekday month day year format System Time Set the system time followi...

Страница 43: ...IOS Setup 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu s...

Страница 44: ...xpansion ROM Options available Enabled Disabled Default setting is Enabled PERR Generation When this item is set to enabled PCI bus parity error PERR is generated and is routed to NMI Options availabl...

Страница 45: ...TPM State Note Select Enabled to activate TPM State function Options available Enabled Disabled Default setting is Enabled Pending Operation Note Determine the action when operation is pending Options...

Страница 46: ...BIOS Setup 46 5 2 3 CPU Configuration...

Страница 47: ...sor core Intel HT Technology Display Intel Hyper Threading Technology function support information Intel VT x Technology Display Intel Virtualization Technology function support information Cache Info...

Страница 48: ...led Disabled Default setting is Disabled Execute Disable Bit When enabled the processor prevents the execution of code in data only memory pages This provides some protection against buffer overflow a...

Страница 49: ...s four processing cores to improve performance with applications that are not multi threaded or optimized for quad core processors Options available Enabled Disabled Default setting is Enabled CPU C3...

Страница 50: ...BIOS Setup 50 5 2 4 Runtime Error Logging Runtime Error Logging Enable Disable Runtime error logging support Options available Enabled Disabled Default setting is Disabled...

Страница 51: ...to access RAID setup utility RAID Mode When set to RAID the SATA controllerenables both its RAID and AHCI functions You will be allows access the RAID setup utility at boot time AHCI Mode When set to...

Страница 52: ...BIOS Setup 52 5 2 6 Super IO Configuration...

Страница 53: ...Displays the Serial Port 1 2 base I O addressand IRQ Change Settings Change Serial Port 1 2 device settings When set to Auto allows the server s BIOS or OS to select a configuration Options available...

Страница 54: ...onsole redirection Options available VT100 VT100 ANSI VT UTF8 Bits per second Select the baud rate for console redirection Options available 9600 19200 57600 115200 Data Bits Select the data bits for...

Страница 55: ...ptions available Enabled Disabled Default setting is Enabled Serial Port for Out of Bnad Management Windows Emerency Service EMS Console Redirection Note Select whether to enable console redirection f...

Страница 56: ...Setup 56 5 3 Chipset Menu The Chipset menu display submenu options for configuring the function of North Bridge and South Bridge Select a submenu item then press Enter to access the related submenu sc...

Страница 57: ...the cuurent memory speed Memory Mode Determine the memory mode When set to Indendent mode all DIMMs are available to the operation system When set to Mirroring mode the motherboard maintains two iden...

Страница 58: ...T Disabled Default setting is Disabled DIMM Voltage Configure the DIMM voltage Options available Auto Force 1 5v Force 1 35v Default setting is Auto Enforce DIMM To enforce POR function When disabled...

Страница 59: ...59 BIOS Setup 5 3 1 1 IOH Configuration...

Страница 60: ...N3 PCIE Slot 2 Speed Select PCIe slot 2 speed Options available GEN1 GEN2 GEN3 Default setting is GEN3 IOH 1 PCIe port Bifurcation Control PCIE Slot 4 Speed Select PCIe slot 4 speed Options available...

Страница 61: ...ormation CPU Socket 0 DDR3_P0_A0 DDR3_P0_A1 DDR3_P0_B0 DDR3_P0_B1 DDR3_P0_C0 DDR3_P0_C1 Status The size of memory installed on each of the DDR3 slots CPU Socket 1 DDR3_P0_E0 DDR3_P0_E1 DDR3_P0_F0 DDR3...

Страница 62: ...eturn to the active power state prior to shutdown When set to Stay Off the system remains off after power shutdown Options available Last State Stay Off Power On The default setting depends on the BMC...

Страница 63: ...63 BIOS Setup 5 3 3 ME Subsystem Intel ME Subsystem Configuration ME Subsystem Enable Disable ME Subsystem function Options available Enabled Disabled Default setting is Enabled...

Страница 64: ...o the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Administrator Pa...

Страница 65: ...Press Enter to access the related sub menu BMC LAN Configuration BMC LAN Configuration Press Enter to access the related submenu System Event Log Press Enter to access the related system event log Sel...

Страница 66: ...S Setup 66 5 5 1 System Information The System Management submenu is a simple display page for basic system ID information as well as Sys tem product information Items on this window are non configura...

Страница 67: ...lect to configure LAN channel parameters statically or dynamically DHCP Do nothing option will not modify any BMC network parameters during BIOS phase Options available Static Dynamic Do Nothing Defau...

Страница 68: ...r advanced configuration Bootup Configuration Bootup NumLock State Enable or Disable Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enables or disables showing the l...

Страница 69: ...t manager menu allows you to specify the boot up drive BIOS setup will display an error message if the legacy drive s specified is not bootable Boot Override UEFI Built in EFI Shell Press Enter to con...

Страница 70: ...made in the BIOS setup Options available Yes No Discard Changes Discards all changes made in the BIOS setup Options available Yes No Load Default Values Loads the default settings for all BIOS setup p...

Страница 71: ...71 BIOS Setup Load User Default Values Loads the user default settings for all BIOS setup parameters Options available Yes No...

Страница 72: ...found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not a...

Страница 73: ...ck can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Change xxx ROM to amiboot rom 2 Copy amiboot rom and AFUDO...

Страница 74: ...BIOS Setup 74 6 BIOS updated...

Отзывы: