background image

2 5

BIOS Setup

<

Ç

>

Move to previous item

<

È

>

Move to next item

<

Å

>

Move to the item in the left hand

<

Æ

>

Move to the item in the right hand

<Esc>

Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and
Option Page Setup Menu - Exit current page and return to Main Menu

<+/PgUp> Increase the numeric value or make changes
<-/PgDn>

Decrease the numeric value or make changes

<F1>

General help, only for Status Page Setup Menu and Option Page Setup Menu

<F2>

Reserved

<F3>

Reserved

<F4>

Reserved

<F6>

Reserved

<F7>

Reserved

<F8>

Reserved

<F9>

Load the Optimized Defaults

<F10>

Save all the CMOS changes, only for Main Menu

BIOS Setup is an overview of the BIOS Setup Program. The program that allows users to modify the
basic system configuration. This type of information is stored in battery-backed CMOS RAM so that it
retains the Setup information when the power is turned off.

ENTERING SETUP

Power ON the computer and press <F2> immediately will allow you to enter Setup.

CONTROL KEYS

Chapter 6 BIOS Setup

Содержание GS-R115L-RH

Страница 1: ...System Installation Guide GS R115V RH GS R115L RH 1U Rack Mount Server Intel Pentium LGA775 Processor Serverboard Rev 1 0 25A08G 015V0 F00 ...

Страница 2: ...Expansion Card Installation 14 Step 2 6 Hard Disk Drive Installation 15 GS R115V RH 15 GS R115L RH 16 Step 2 7 FAN Duct Removal and Installation 17 Chapter 4 Appearance of GS R115 RH 18 4 1 Front View of GS R115V RH 18 4 2 Front View of GS R115L RH 18 4 3 Rear View of GS R115 RH 19 4 4 Switch and LED Indicators Introduction 20 4 5 LAN LED Description 21 4 6 Connector Icon Description 22 Chapter 5 ...

Страница 3: ...og Configuration 51 Boot 54 Exit 55 Chapter 7 INTEL RAID BIOS Configuration 61 Chapter 8 Application Driver Installation 66 A Intel Chipset Software Installation Utilities 66 B Intel LAN Driver Installation 69 C XGI VGA Driver Installation 73 D Intel ICH7R RAID Driver Installation 76 E Matrix Storgae Manager Utility Installation 78 F DirectX 9 0C Driver Installation 82 ...

Страница 4: ...roductusageinstructions Do not use this product near water or a heat source Set up the product on a stable work surface or so as to ensure stability of the system Openingsinthecaseareprovidedforventilation Donotblockorcovertheseopenings Makesureyou provide adequate space around the system for ventilation when you set up your work area Never insert objects of any kind into the ventilation openings ...

Страница 5: ...is own expense Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits Neither the provider nor the manufacturer are responsible for any radio or television interference caused by using other than recommended cables and connectors or by unauthorized changes or modificationstothisequipment Unauthorizedchangesormodificationscouldvoidtheuser sauthorityto...

Страница 6: ...anDepartmentofCommunicationslabelidentifiescertifiedequipment Thiscertification meansthattheequipmentmeetscertaintelecommunicationsnetworkprotective operationalandsafety requirements TheDepartmentdoesnotguaranteetheequipmentwilloperatetotheusersatisfaction Beforeinstallingthisequipment usersensurethatitispermissibletobeconnectedtothefacilitiesofthe localTelecommunicationsCompany Theequipmentmustal...

Страница 7: ...ading The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100 for European users only CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent typerecommendedbythemanufacturer Disposeofusedbatteriesaccordingtothe manufacturer sinstructio...

Страница 8: ... guide will assist you in installing all the essential components for the sever system Foryourprotection pleasereadandundertandallofthesafetyandoperatinginstructionsregardingyour Gigabyte Server and retain for future reference The procedures in this guidebook assume that your are a system or network administrator experienced in installing similar hardware Contents Packages Whenopeningthepackage pl...

Страница 9: ...e bit Errors Correction Multiple Bit Errors Detection Expansion Slot 1 Riser card supports 1 PCI E x8 and 1 PCI E x4 add on cards 1 Riser card supports 1 PCI E x8 low profile and 1 PCI X 100 133MHz add on cards SATA RAID controller ICH7R Supports SATARAID 0 1 Cooling Fans 5 X System Fan Integrated LANs Controller DualIntel82573L GigabitEthernetcontrollers Integrated Graphics Controller XGI Volari ...

Страница 10: ...h ROM Server Management Functions Optional device BMC Chip H8S IPMI 2 0 controller FailureDetection IPMI 2 0 specification of Server management EventLogging 32KB Nonvolatile Memory to Log System Failure Events RemoteManagement Follow the IPMI 2 0 specification of Server management Environment AmbientTemperature OperatingTemperature 5o C to 35o C Non operatingTemperature 0o C to 50o C Relative Humi...

Страница 11: ...ion Step 1 Loosen the thumbscrew from the back of the server Step 2 Push down the indentation located at two sides of the chassis and slide toward to remove the top cover Step 3 Reverse Step 1 and 2 to replace the chassis cover Chapter 2 System Hardware Installation Step 2 Note Before installing CPU you must remove the FAN duct For FAN duct removal please see Sub section 2 7 FAN Duct Removal and I...

Страница 12: ... Step 1 Step 2 Step 4 Step1 Raise the metal locking lever on the socket Step2 Remove the plastic covering on the CPU socket Step3 Lift the metal cover Step4 Insert the CPU with the correct orientation The CPU only fits in one orientation Step5 Once the CPU is properly placed please replace the metal cover and push the metal lever back into locked position ...

Страница 13: ...sing the retaining clips outwards 2 Aling a DIMM on the socket such that the notch on the DIMM exactly match the notches in the socket 3 Firmly insert the DIMMinto the socket until the retaining clips snap back in place 4 When installing the DIMM into the DIMM socket we recommend to populate one DIMM in Channel A module and one in Channel B module for best performance Please note that each logical...

Страница 14: ...for PCI X full height full length is 228 5 mm x 91 5 mm size limitation for Low Profile Card 167 5 mm x 56 mm Step 1 Lift the riser bracket slightly then pull it out from the server chassis Step 2 Lossen the screw on the riser bracket Step 2 Aligntheexpansioncardwiththeguidinggroove Slidetheexpansioncardintotheslotuntilthe card firmly seats Step 3 Align the riser bracket to the system module see t...

Страница 15: ...ton and pull the blank out of the drive bay Step 2 Remove the plastic hard disk tray Step 3 Slide hard disk into blank and secure it with screws Step 4 Toreplacetheharddriveblank slidetheblankintothebayuntilitlocksintoplace Connectcable and power Step 5 Place the hard disk into the server system Step 3 GS R115V RH ...

Страница 16: ...o remove the hard drive plate from system Step 3 Place hard disk on the plate and lock hard drive with 4 screws Step 4 Replace the hard drive plate slide the blank into the bay until it locks into place Connect HDD power cable Step 5 Reverse step 1 2 3 and 4 to complete the HDD installtion GS R115L RH Step 1 Remove Step 2 ...

Страница 17: ...nstallation Step 1 Pull up the screw holder and lossen the thumbscrews Lift up to remove the fan duct Step 2 For FAN Duct Installation place the fan duct on the top of heat sinks Fasten the screws to the locked position and push down the screw holders Step 1 Step 2 ...

Страница 18: ... RH M O R D C e p y T m i l S s D D H A T A S p a w S t o H r o t c e n n o C B S U s D E L n o i t c e r i d e R e l o s n o C r o F 5 4 J R 4 2 Front View of GS R115L RH M O R D C e p y T m i l S y p o o l F d r a d n a t S r o t c e n n o C B S U s D E L n o i t c e r i d e R e l o s n o C r o F 5 4 J R ...

Страница 19: ...15 RH r e w o P t r o P A G V t r o P M O C t o l S r e s i R e l i f o r P w o L t o l S r e s i R h t g n e l l l u F e z i s l l u F r o t c e n n o C d r a o b y e K r o t c e n n o C e s u o M s r o t c e n n o C B S U s t r o P 2 1 N A L ...

Страница 20: ...On Power On Green Blink Sleep S1 Off Power Off S4 S5 Green On System Ready On Alarm Amber Blink System Ready but deqraded DIMM Killed Amber On CriticalAlarm Critical FANs Failure Off System Not Ready Post error NMI event No Power Green Blink Hard Disk Drive Access Off No Access and No HDD Fault Green On LAN Link No access Green Blink LAN access Off Idle Green On LAN Link No access Green Blink LAN ...

Страница 21: ...een ON LAN Link no Access Green BLINK LAN Access OFF Idle Yellow ON 1Gbpsconnection Yellow BLINK Portidentificationwith1Gbpsconnection Green ON 100Mbpsconnection Green BLINK Portidentificationwith10or100Mbpsconnection OFF 10Mbpsconnection Name LAN Link Activity GbE LAN Speed ...

Страница 22: ...22 GS R115V RH GS R115L RH Rack Mount Server 4 6 Connector Icon Description n o c I t s e g g u S n o i t p i r c s e D d r a o b y e K A G V e s u o M N A L t r o P l a i r e S B S U ...

Страница 23: ...23 MotherboardLayout 5 1 GA 5EXSH RH Motherboard Jumpper Setting Chapter 5 Motherboard Jumper Setting CLR_CMOS RECOVERY ...

Страница 24: ...es by this jumper Default value doesn t include the Shunter to prevent from improper use this jumper To clear CMOS temporarily short 1 2 pin 1 1 1 2 close Clear CMOS 2 3close Normal Defaultsetting 2 BIOS_WP BIOS Write Protect Function 1 1 1 2 close Enable BIOS Recovery function 2 3 close Disable this function Defaultsetting ...

Страница 25: ...help only for Status Page Setup Menu and Option Page Setup Menu F2 Reserved F3 Reserved F4 Reserved F6 Reserved F7 Reserved F8 Reserved F9 LoadtheOptimizedDefaults F10 Save all the CMOS changes only for Main Menu BIOS Setup is an overview of the BIOS Setup Program The program that allows users to modify the basic system configuration This type of information is stored in battery backed CMOS RAM so...

Страница 26: ...er Serveradditionalfeaturesenabled disabledsetupmenus z z z z z Boot Thissetuppageincludealltheitemsoffirstbootfunctionfeatures z z z z z Exit There are five optionsin this selection Exit Saving Changes Exit Discarding Changes Load Optimal Defaults Load Failsafe Defaults and Discard Changes GETTINGHELP MainMenu Theon linedescriptionofthehighlightedsetupfunctionisdisplayedatthebottomofthescreen Sta...

Страница 27: ...keys to select among the items and press Enter to accept or enter the sub menu System Time The time is calculated based on the 24 hour military time clock Set the System Time HH MM SS SystemDate Set the System Date Note that the Day automatically changed after you set the date Weekend DD MM YY YY 1099 2099 Figure 1 Main ...

Страница 28: ...mat The 1 25MB 31 2 diskette requires 3 Mode floppy disk drive IDE Primary Master Slave Secondary Master Slave ParallelATA The category identifies the types of hard disk from drive C to F that has been installed in the computer There are two types auto type and manual type Manual type is user definable Auto type which will automatically detect HDD type Note that the specifications of your drive mu...

Страница 29: ...of Multi Sector Transfer Mode Disabled The data transfer from and to the device occurs one sector at a time Auto The data transfer from and to the device occurs multiple sectors at a time if the device supportsit LBA Mode This field shows if the device type in the specific IDE channel support LBA Mode 32 Bit I O Enable this function to max imize the IDE data transfer rate Transfer Mode This field ...

Страница 30: ...ermal Management 2 C1 Enhanced Mode Intel Virtualization Technology No Execute Mode Memory Protection Frequency Ratio and Processor Power Management ThermalManagement2 ThermalManagement2enhancesthefeaturesofpowerreductioncapability WhenTM2isenabled it will reduce the frequency and VID which results in a saving of power consumption of processor Enabled EnabledThermalManagement2 Defaultsetting Disab...

Страница 31: ... multiple virtual systems With processor and I O enhancements to Intel s various platforms Intel VirtualizationTechnology can improve the performance and robustness of today s software only virtual machine solutions Enabled Enabled VT Feature Disabled Disables VT Feature Default setting NoExecuteModeMem Protection Enabled Enable No Execute Mode Memory Protection function Default value Disabled Dis...

Страница 32: ...nformation from the processor It is a proprietary single wire bus between the processor and the chipset or other health monitoring device Data from the Digital Thermal Sensors are processed and stored in a processor register MSR which is queried through the Platform Environment Control Interface PECI Enabled Enable PECI Interface Disabled Disablethisfunction Defaultsetting ...

Страница 33: ...anced About This Section Advanced With this section allowing user to configure your system for basic operation User can change theprocessoroptions chipsetconfiguration PCIconfigurationandchipsetcontrol Figure 2 Advanced ...

Страница 34: ...play only which is determined by POST Power On Self Test of the BIOS Memory Reset Yes Select Yes system will clear the memory error status Save the changes and restart system After rebooting system the Memory Reset item will set to No automatically Default setting No Disablethisfunction ExtendRAMStep Enabled Enable test extended memroy process Disabled Disablethisfunction Defaultsetting ...

Страница 35: ...oard LAN device Default setting Disabled Disablethisfunction Option ROM Scan Enabled Enableing this item to initialize device expansion ROM Disabled Disablethisfunction Defualtsetting PCI Slot 1 2 Option ROM Enabled Enableing this item to initialize device expansion ROM Defualtsetting Disabled Disablethisfunction ...

Страница 36: ...36 GS R115V RH GS R115L RH Rack Mount Server SIO ITE8718F Configuration Figure 2 3 SIO ITE8718F Configuration ...

Страница 37: ...2E8 Set IO address to 2E8 Serial Port B This allows users to configure serial prot B by using this option Enabled Enabletheconfiguration Disabled Disabletheconfiguration Defaultsetting Base I O Address IRQ 3F8 Set IO address to 3F8 2F8 Set IO address to 2F8 Default setting 3E8 Set IO address to 3E8 2E8 Set IO address to 2E8 Base I O Address 378 Set IO address to 378 278 Set IO address to 278 Iterr...

Страница 38: ...abled Enable USB controller Default setting Disabled Disbalethisfunction USB 2 0 Controller This item allows users to enable or disable the USB 2 0 device by setting item to the desired value Enabled Enable USB 2 0 controller Disabled Disbalethisfunction Defaultsetting Legacy USB Support This option allows user to function support for legacy USB Enabled Enables support for legacy USB Default setti...

Страница 39: ...setting SerialATA Set Native mode to Serial ATA SATA Controller Mode Option Compatible Mode SATAand PATAdrives are auto detected and placed in Legacy mode Default setting Enhanced Mode SATAand PATAdrives are auto detected and placed in Native mode Note Pre Win2000 operating system do not work in Enhanced mode SATA AHCI Enable Enabled Set this item to enable SATAAHCI function for WinXP SP1 IAA driv...

Страница 40: ...40 GS R115V RH GS R115L RH Rack Mount Server ...

Страница 41: ...41 BIOS Setup Advanced Chipset Control Figure 2 4 Advanced Chipset Control EnableMultimediaTimer Yes Enable Multimedia Timer support No Disablethisfunction Defaultsetting ...

Страница 42: ...rdware Monitor Voltage Monitor DDR1V8 VCC3 VCORE 12V1 VCC1V5 VBAT Detect system s voltage status automatically FAN Monitor UF 1 2 3 4 5 RPM Display the current System 1 2 34 and CPU fan speed This Menu will disappear when BMC module is populated ...

Страница 43: ...en system boot Enabled EnableBoot timeDiagnostic Disabled Disable this function Default value Reset ConfigurationData Yes Resetallconfigurationdata No Do not make any changes Default value NumLock This option allows user to select power on state for NumLock On Enable NumLock Off Disablethisfunction ...

Страница 44: ...a memory or proocessor error cooured Defaultsetting Halt System will stop if an error is detected during power up Multiprocessor Specification This option allows user to configure the multiprocessor MP specification revision level Some operating system will require 1 1 for compatibility reasons 1 4 Support MPS Version 1 4 Default setting 1 1 Support M PS Version 1 1 ...

Страница 45: ...ave the right to change the options of the setup menus When you select this function the following message will appear at the center of the screen to assist you in creating a password Type the password up to 6 characters in lengh and press Enter The password typed now will clear any previously entered password from the CMOS memory You will be asked to confirm the entered password Type the password...

Страница 46: ...d password from the CMOS memory You will be asked to confirm the entered password Type the password again and press Enter You may also press Esc to abort the selection and not enter a specified password or press Enter key to disable this option Passwordonboot Password entering will be required when system on boot Enabled Requries entering password when system on boot Disabled Disable this function...

Страница 47: ...47 BIOS Setup Server Figure 4 Server ...

Страница 48: ...anagement ServerManagement This category allows user to view the server management features Including information of BIOS Version All items in this menu cannot be modified in user s mode If any items require changes please consult your system supervisor ...

Страница 49: ... Use COMA as he COM port address Disabled Disablethisfunction Defaultsetting Note Tower has COMA and COMB BaudRate This option allows user to set the specified baud rate Options 300 1200 2400 9600 19 2K 38 4K 57 6K 115 2K TerminalType This option allows user to select the specified terminal type This is defined by IEEE Options VT100 VT100 8bit PC ANSI 7bit VT100 VT UTF8 ...

Страница 50: ...ld indicates whether the console is connected directly to the system or a modem is used to connect Direct Console is connected directly to the system Default setting Disabled Console is connected via the modem Continue C R after POST This option allows user to enable console redirection after O S has loaded On Enable console redirection after O S has loaded Off Disablethisfunction Defaultsetting ...

Страница 51: ...guration Figure 4 3 Event Log Configuration EventLogConfuguration This option contains additional setup menu to configure the Event Log Configuration Clear all Event Logs Enter The system event log will be cleared if pressing Enter ...

Страница 52: ...e Assert NMI on SERR Default setting Disabled Disablethisfunction Post Error Pause If this item is set to enabled the system will wai for user intervention on critical POST errors If this item is disabled the system will boot with no intervention if possible Enabled Enable Post Error Pause Default setting Disabled Disablethisfunction ...

Страница 53: ...back LastState Set system to the last sate whenAC power is removed Do not power on system when AC power is back Default setting MiniBMCFunction Enabled Enable Mini BMC function Default setting Disabled Disablethisfunction This option will disappear and disable when BMC module is populated MiniBMCSELView Press Enter to view the Mini BMC SEL This option will disappear and disable when BMC module is ...

Страница 54: ...fies the boot sequence from the available devices If the first device is not a bootable device the system will seek for next available device Key used to view ot configure devices Up and Down arrows select a device and moves the device up or down f and r specifies the device fixed or removable x exclude or include the device to boot 1 4 Loads default boot secquence ...

Страница 55: ...u have changed all of the set values in the BIOS setup you should save your changes and exit BIOS setup program Select Exit from the menu bar to display the followingsub menu Exit Saving Changes Exit Discarding Changes Load Settup Default Discard Change Save Changes ...

Страница 56: ...ving the changes Press Enter on this item to ask for the following confirmation message Pressing Y to store all the present setting values tha user made in this time into CMOS Therefore whenyou boot up your computer next time the BIOS will re configure your system according data in CMOS ...

Страница 57: ...hanges This option allows user to exit system setup without changing any previous settings values in CMOS The previous selection remain in effect This will exit the Setup Utility and restart your compuetr when selecting this option ...

Страница 58: ...58 BIOS Setup LoadSettupDefault This option allows user to load default values for all setup items When you press Enter on this item you will get a confirmation dialog box with a message as below ...

Страница 59: ...59 BIOS Setup Discard Changes This option allows user to load previos values from CMOS for all setup item When you press Enter on this item you will get a confirmation dialog box with a message as below ...

Страница 60: ...OS Setup Save Changes This option allows user to save setup dat ato CMOS When you press Enter on this item you will get a confirmation dialog box with a message as below Press Yes to save setup daya to CMOS ...

Страница 61: ... Matrix Storage Manager option ROM V5 0 0 1011 ICH7R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reversed RAID Volumes None Defined Physical Disks Port Driver Model Serial Size Type Status Vol ID 0 ST3120026AS 3JT354CP 111 7GB Non RAID Disk 1 ST3120026AS 3JT329JX 111 7GB Non RAID Disk Press CTRL I to enter Configuration Utility Intel R Matrix Storage Manager option ROM V5 0 0 1011 ICH7...

Страница 62: ...er setting disk name press Enter to select RAID Level There are four RAID levels RAID0 Stripe RAID1 Mirror RAID 0 1 Striping Mirroring and RAID5 After selecting the RAID level press Enter to select Strip Size Intel R Matrix Storage Manager option ROM V5 0 0 1011 ICH7R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reversed CREATE VOLUME MENU HELP Choose the RAID level best suited to your ...

Страница 63: ...acity is chosen creation of a second volume is needed to utilize the remaining space KL Change TAB Next ESC Previous Menu ENTER Select Name RAID_Volume0 RAID Level RAID0 Stripe Disks Select Disks Strip Size 128KB Capacity 223 5 GB Create Volume Press Enter to enter Create Volume after setting disk capacity Intel R Matrix Storage Manager option ROM V5 0 0 1011 ICH7R wRAID5 Copyright C 2003 04 Intel...

Страница 64: ... 223 5 GB Create Volume An alert bar will be displayed warning you that all data on selected disks will be lost Please press Y to complete the set up of RAID Intel R Matrix Storage Manager option ROM V5 0 0 1011 ICH7R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reversed CREATE VOLUME MENU HELP Press ENTER to Create the specified volume KL Change TAB Next ESC Previous Menu ENTER Select ...

Страница 65: ...7GB Member Disk 0 1 ST3120026AS 3JT354CP 111 7GB Member Disk 0 KL Select ESC Exit ENTER Select Menu Delete RAID Volume If you want to delete a RAID volume please select the Delete RAID Volume option Press Enter key and follow the instructions on the screen Intel R Matrix Storage Manager option ROM V5 0 0 1011 ICH7R wRAID5 Copyright C 2003 04 Intel Corporation All Rights Reversed MAIN MENU 1 Create...

Страница 66: ...w a series of Setup Wizard dialog boxes If not please double click the CD ROM device icon in My computer and execute the setup exe Installation Procedures 1 The CD auto run program starts Double click on Intel Chipset Software Installation Utilities tostarttheinstallation 2 Then a series of installation wizards appear Follow up the wizards to install the drivers 3 Setup completed click Finish to r...

Страница 67: ...Driver Installation 67 2 InstallShield Wizard Welcome Window 3 License Aggremment 2 Click Next to start the installation 3 License Agreement click Yes ...

Страница 68: ...ount Server 68 4 Readme Information 4 Click Next to process the installation 5 Installation Complete Restart Computer 5 Installation complete Select Yes I want to restart my computer now and click Finish to reboot system ...

Страница 69: ...river CD title will auto start and show a series of Setup Wizard dialog boxes If not please double click the CD ROM device icon in My computer and execute the setup exe Installation Procedures 1 The CD auto run program starts Double click on Intel LAN Driver to start the installation 2 Select Install Driver 3 System starts to install the LAN Driver automatically 1 Autorun ...

Страница 70: ...GS R115V RH Rack Mount Server 70 2 Installation Wizard Welcom Window 3 License Agreement 2 Click Install Driver Item 3 Select I accept the term in the license agreement and click Next ...

Страница 71: ...Types Complete setup type allows users to Installs drivers Intel PROSet for Windows Device Manager and Advanced Networking Services Custom setup type embraces installing features and subfeatures user selects including modern utilities manage ment components and drivers Recommended for advanced users ...

Страница 72: ...GS R115V RH Rack Mount Server 72 5 Click Install to start installation 5 Ready to instll program 6 Installation Complete 6 Wizard Completed Click Finish ...

Страница 73: ... If not please double click the CD ROM device icon in My computer and execute the setup exe Installation Procedures 1 The CD auto run program starts Double click on VGA Driver to start the installation 2 Double click on Display Driver item Then a series of installation wizards appear Follow up the wizards to install the drivers 3 Setup completed click Finish to restart your computer 1 Click VGA Dr...

Страница 74: ...GS R115V RH Rack Mount Server 74 2 Setup Wizard Window 3 InsallShield Wizard Window 2 Double click Display Driver 3 Click Next to start the installation ...

Страница 75: ...Driver Installation 75 4 Installaiton Wizard Completed 4 Installation complete Select Yes I want to restart my computer now and click Finish to reboot system ...

Страница 76: ...tarts Double click on Intel ICH7R RAID Driver to make a driver disk 2 Select a folder refering to your operating system 3 Insert a flopp disk in the floppy drive Click on the self extractor file 4 System starts making a driver disk automatically 5 Driver disk creation completed 1 Click Intel ICH7R RAID Driver item 1 Autorun ...

Страница 77: ...Driver Installation 77 2 Starting make a driver disk Insert a floppy disk and double click the self extractor file 3 Formatting and writing in floppy sidk ...

Страница 78: ...uide If not please double click the CD ROM device icon in My computer and execute the setup exe Installation Procedures 1 The CD auto run program starts Double click on Intel R Matrix Storage Manager to start theinstallation 2 Then a series of installation wizards appear Follow up the wizards to install the drivers 3 Setup completed click Finish to restart your computer 1 Autorun 1 Click Intel R M...

Страница 79: ...Driver Installation 79 2 Setup Wizard 3 Warning Information 2 Click Next 3 Readtheinformationc carefully and click Next tostarttheinstallation ...

Страница 80: ...GS R115V RH Rack Mount Server 80 4 License Agreement 4 Click Yes 5 Readme Information 5 Click Next ...

Страница 81: ...Driver Installation 81 6 Installaiton Wizard completed 6 Click Finish to reboot your system Installationcompleted ...

Страница 82: ...llation guide If not please double click the CD ROM device icon in My computer and execute the setup exe Installation Procedures 1 The CD auto run program starts Double click on Directx9 0C to start the installation 2 Then a series of installation wizards appear Follow up the wizards to install the drivers 3 Setup completed click Finish to restart your computer 1 Autorun 1 Click DirectX 9 0C Drive...

Страница 83: ...Driver Installation 83 2 License Agreement 3 Start Installaiton 3 Click Next to start theinstallation 2 Select I accept the agreement andclick Next to process the installation ...

Страница 84: ...GS R115V RH Rack Mount Server 84 4 Installaiton Wizard completed 4 Click Finish Installation complete ...

Отзывы: