GA-586VX
A-4
Ö
Memory Verify Error at ...
Indicates an error verifying a value already written to memory. Use the
location along with your system's memory map to locate the bad chip.
Ö
OFFENDING ADDRESS NOT FOUND
This message is used in conjunction with the I/O CHANNEL CHECK and
RAM PARITY ERROR messages when the segment that has caused the
problem cannot be isolated.
Ö
OFFENDING SEGMENT:
This message is used in conjunction with the I/O CHANNEL CHECK and
RAM PARITY ERROR messages when the segment that has caused the
problem has been isolated.
Ö
PRESS A KEY TO REBOOT
This will be displayed at the bottom screen when an error occurs that
requires you to reboot. Press any key and the system will reboot.
Ö
PRESS F1 TO DISABLE NMI, F2 TO REBOOT
When BIOS detects a Non-maskable Interrupt condition during boot, this
will allow you to disable the NMI and continue to boot. Or you can reboot
the system, which will enable the NMI.
Ö
RAM PARITY ERROR - CHECKING FOR SEGMENT ...
Indicates a parity error in Random Access Memory.
Ö
Should Be Empty But EISA Board Found
PLEASE RUN EISA CONFIGURATION UTILITY
A valid board ID was found in a slot that was configured as having no
board ID.
F
When this error appears, the system will boot in ISA mode, which allows
you to run the EISA Configuration Utility.
Ö
Should Have EISA Board But Not Found
PLEASE RUN EISA CONFIGURATION UTILITY
The board installed is not responding to the ID request, or no board ID has
been found in the indicated slot.
Содержание GA-586VX
Страница 1: ...GA 586VX USER S MANUAL PCI ISA SOLUTION PENTIUM PCI ISA BUS MAINBOARD REV 2 0 Second Edition...
Страница 5: ...Table of Contents 5 CPU 1 D SYNC DRAM two banks install CPU III Quick Installation Guide...
Страница 30: ......
Страница 36: ......
Страница 43: ...GA 586VX 3 5 32MB 2pcs 32MB 2pcs 128 MB 64MB 64MB 128MB...
Страница 46: ......
Страница 72: ...AT Technical Information 5 2 5 1 2 PCI BUS SLOT PIN OUT Pentium 200 MHz P55C 200MHz CPU 1 2 3 4 ON OFF SW...
Страница 76: ......
Страница 82: ......