BIOS Setup
5-4-1 RAS
Parameter
Description
RAS Periodic SMI Control
Enable/Disable the Periodic SMI for polling [MCA Threshold] error.
Options available: Enabled/Disabled. Default setting is
Enabled
.
SMI Threshold
Configures the SMI Threshold value.
SMI Scale
Configures the SMI Scale value.
SMI Scale Unit
Defines the unit of time scale.
Options available: millisecond, second, minute. Default setting is
millsecond
.
SMI Period
Configures the SMI Period.
GHES Notify Type
Selects the Notification type for deferred/ corrected errors.
Options available: Polled/SCI. Default setting is
Polled
.
GHES UnCorr Notify Type
Selects the Notification type for uncorrected errors.
Options available: Polled/NMI. Default setting is
NMI
.
PCIe GHES Notify Type
Selects the Notification type for PCIe corrected errors.
Options available: Polled/SCI. Default setting is
Polled
.
PCIe UnCorr GHES Notify
Type
Selects the Notification type for PCIe uncorrected errors.
Options available: Polled/NMI. Default setting is
NMI
.
PCIe Root Port Corr Err
Mask Reg
Initialize the PCIe AER Corrected Error Mask register of Root Port.
Содержание G262-ZL0
Страница 1: ...G262 ZL0 HPC Server 2U DP SXM4 A100 4 GPU Server Liquid Cooling Solution User Manual Rev 1 0 ...
Страница 10: ... 10 This page intentionally left blank ...
Страница 16: ...Hardware Installation 16 1 3 System Block Diagram ...
Страница 36: ...System Hardware Installation 36 3 11 Cable Routing Front Switch Cable Front LED Cable GPU Power Cable ...
Страница 37: ... 37 System Hardware Installation HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable ...
Страница 38: ...System Hardware Installation 38 HDD Back Panel Board NVMe Signal Cable ...
Страница 39: ... 39 System Hardware Installation PCIe Signal Cable ...
Страница 40: ...System Hardware Installation 40 System Power Cable Power Supply Signal Cable ...
Страница 41: ... 41 System Hardware Installation On Board SATA Cable ...
Страница 42: ...System Hardware Installation 42 This page intentionally left blank ...
Страница 46: ...Motherboard Components 46 This page intentionally left blank ...
Страница 52: ...BIOS Setup 52 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...
Страница 57: ... 57 BIOS Setup 5 2 4 1 Serial Port 1 Configuration ...
Страница 65: ... 65 BIOS Setup 5 2 8 PCI Subsystem Settings ...
Страница 76: ...BIOS Setup 76 5 2 17 Intel R I350 Gigabit Network Connection ...
Страница 82: ...BIOS Setup 82 5 3 1 CPU Common Options ...
Страница 95: ... 95 BIOS Setup 5 3 3 1 1 Enforce POR ...
Страница 141: ... 141 BIOS Setup This page intentionally left blank ...