![Gigabyte 7ZXR Series Скачать руководство пользователя страница 78](http://html1.mh-extra.com/html/gigabyte/7zxr-series/7zxr-series_user-manual_2223430078.webp)
7ZXR Series Motherboard
71
Rebuilding A Mirrored Array
The Rebuild Array <5> Menu option is necessary to recover from an error in a mirrored disk
array. You will receive an error message when booting your system from the BIOS.
NOTE: Drives MUST be replaced if they contain any physical errors.
Follow these steps BEFORE using the Rebuild Array menu option:
1. On bootup, the system Startup BIOS will display an error message identifying which drive
has failed.
2. Press <Ctrl-F> keys to enter FastBuild Main Menu.
3. Select submenu Define Array <3>.
4. Select the failed array and identify the Channel and ID of the failed drive.
5. Power off and physically remove the failed drive.
6. Replace the drive with an identical model.
7. Reboot the system and enter the FastBuild Main Menu.
8. Select the <5> Rebuild Array option. The following screen will appear.
FastBuild (tm) Utility 1.xx (c) 1995-2000 Promise Technology, Inc.
[ Rebuild Array Menu ]
Array No RAID Mode
Total Drv
Capacity(MB) Status
Array 1
Mirror 2
16126 Critical
Array 2
Stripe
1
8063 Functional
Array 3
Stripe
1 8063 Functional
Array 4
——
—— —— ——
[ Keys Available ]
[
↑
] Up [
↓
] Down [ESC] Exit [Enter] Select
9. Highlight the array whose Status is “Critical”.
10. Press [Enter]. The following screen will then appear (see next page).
Содержание 7ZXR Series
Страница 4: ......
Страница 6: ......
Страница 113: ...Appendix 106 7 8 9 10 6 Click Next 7 Click Next 9 Click Next 10 Click Finish to restart computer...
Страница 115: ...Appendix 108 7 8 9 Click Finish to restart computer 7 Click here 8 Click Next...
Страница 119: ...Appendix 112 7 8 9 10 11 12 11 Click Finish to restart 8 Click Next 7 Click Next 6 Click Next 9 Click Next 10 Click Next...