Series 8650A Universal Power Meters
2-14
Manual 31470, Rev. E, April 2001
4.
A name of up to 16 characters can be used as an additional means of identifying the setup. Press
[
Name
} to open the display containing this option. Set the name by moving the cursor to the
first position desired with the < and > softkeys, then select the character for that position with
the cursor keys. Repeat this process for each character in the name.
5.
Press [
OK
] to accept the stored data or press [
Cancel
] TWICE to cancel the changes, and return
to the Power Meter Configuration menu.
Service
This is presently used only to clear all memory in the 8650A. When you press [
Service
], you will be
prompted to press [
Clear Mem
] to clear all calibration, configuration, and measurement data currently
stored in the 8650A RAM. Data stored in sensor EEPROMs are not affected.
2.2.2
Display Setup
Use this option to configure the data and format that will display on each line of the screen.
From the Main Menu, press [
Display Setup
] to select the Configure Display menu (see Figure 2-11). This
screen is the same as the Main Menu except the control items are changed to display line configuration
options. The configuration of each line includes the source and data format, data resolution, and
peaking meter (bar graph) when configuration for use. In addition, the control to set the screen
brightness is included in this display (Other Options).
One to four lines of data can be configured, and any attached sensor can be mapped to any of the four
lines. Other information items are displayed at the top of the screen. These include
CAL ON
, which
displays whenever the calibration RF source is on;
REMOTE
,
which displays whenever the power
meter is being operated by remote control (GPIB or RS-232); and configured inputs
A, B, A/B, A-B,
B/A
and
B-A
.
NOTE:
The above input configurations are available only in the Model 8652A. The single-
channel Model 8651A will have input A only.
Figure 2-11: The Configuration Display Menu
☛
☛
☛
☛
CAL ON
A - 70.999
B - 54.245
- 16.754
CW
dB
CW
dBm
CW
dBm
dB
Configure Display
Line 1
Line 2
Line 3
Line 4
More
Options
Cancel
-24.246
A/B
-B
A
Содержание 8650A Series
Страница 4: ......
Страница 12: ...Series 8650A Universal Power Meters viii Manual 31470 Rev E April 2001 ...
Страница 16: ...Series 8650A Universal Power Meters xii Manual 31470 Rev E April 2001 ...
Страница 18: ...Series 8650A Universal Power Meters xiv Manual 31470 Rev E April 2001 ...
Страница 20: ...Series 8650A Universal Power Meters xvi Manual 31470 Rev E April 2001 ...
Страница 32: ...Series 8650A Universal Power Meters 1 12 Manual 31470 Rev E April 2001 ...
Страница 198: ...Series 8650A Universal Power Meters 3 124 Manual 31470 Rev E April 2001 ...
Страница 216: ...Series 8650A Universal Power Meters A 8 Manual 31470 Rev E April 2001 ...
Страница 228: ...Series 8650A Universal Power Meters B 12 Manual 31470 Rev E April 2001 ...
Страница 240: ...Series 8650A Universal Power Meters Index 6 Manual 31470 Rev E April 2001 ...