background image

- 111 -

BIOS Setup

5-3-7  SOC Miscellaneous Control

Parameter

Description

Soc Miscellaneous Control

ABL Console Out Control

Enable = Enable ConsoleOut Function for ABL
Disable = Disable ConsoleOut Function for ABL
Auto = Keep default behavior
Options available: Disable/Enable/Auto. Default setting is 

Auto

.

Содержание R182-Z90

Страница 1: ...R182 Z90 R182 Z91 R182 Z92 MZ92 FS0 Motherboard With Dual Sockets forAMD EPYCTM 7002 Series Family Processors User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ...d the point where the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...Ds 25 Chapter 3 System Hardware Installation 27 3 1 Removing Chassis Cover 28 3 2 Removing and Installing the Fan Duct 29 3 3 Removing the Heat Sink 30 3 4 Installing the CPU 31 3 5 Installing the Memory 33 3 5 1 Eight Channel Memory Configuration 33 3 5 2 Installing a Memory 34 3 5 3 DIMM Population Table 34 3 6 Installing the PCI Expansion Card 36 3 7 Installing the Mezannine Card 37 3 7 1 OCP 3...

Страница 8: ...guration 76 5 2 8 PCI Subsystem Settings 77 5 2 9 USB Configuration 79 5 2 10 NVMe Configuration 81 5 2 11 SATA Configuration 82 5 2 12 Network Stack Configuration 83 5 2 13 AMD Mem Configuration Status 84 5 2 14 iSCSI Configuration 85 5 2 15 Tls Auth Configuration 86 5 2 16 Intel R I350 Gigabit Network Connection 87 5 2 17 VLAN Configuration 89 5 2 18 MAC IPv4 Network Configuration 91 5 2 19 MAC ...

Страница 9: ...points 132 5 10 6 Topology test points 132 5 10 7 Extended memory test point 132 5 10 8 Gnb Earlier init 133 5 10 9 PMU test points 136 5 10 10 ABL0 test points 136 5 10 11 ABL5 test points 136 5 11 Agesa POST Codes 140 5 11 1 Universal Post Code 140 5 11 2 0xA1XX For CZ only memory Postcodes 140 5 11 3 S3 Interface Post Code 143 5 11 4 PMU Post Code 143 5 11 5 0xA5XX assigned for AGESA PSP Module...

Страница 10: ... 10 This page left intentionally blankThis ...

Страница 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Страница 12: ...memory per processor architecture RDIMM modules up to 64GB supported LRDIMM modules up to 128GB supported Memory speed Up to 3200 MHz 1DPC 2933 MHz 2DPC LAN 2 x 1GbE LAN ports 1 x Intel I350 AM2 1 x 10 100 1000 management LAN Expansion Slot R182 Z90 Riser Card CRS101E 1 x PCIe x16 slot Gen4 x16 FHHL Riser Card CRS101E 1 x PCIe x16 slot Gen4 x16 FHHL 1 x OCP 3 0 mezzanine slot with PCIe Gen4 x16 ba...

Страница 13: ...M 2 slot M key PCIe Gen3 x4 Supports NGFF 2242 2260 2280 22110 cards R182 Z92 Riser Card CRS101E 1 x PCIe x16 slot Gen4 x16 FHHL Riser Card CRS101E 1 x PCIe x16 slot Gen4 x16 FHHL 1 x OCP 3 0 mezzanine slot with PCIe Gen4 x16 bandwidth from CPU_0 Supported NCSI function 1 x OCP 2 0 mezzanine slot with PCIe Gen3 x8 bandwidth Type1 P1 P2 Supported NCSI function 1 x M 2 slot M key PCIe Gen3 x4 Suppor...

Страница 14: ...eader 1 x TPM header 1 x Front panel header 1 x HDD back plane board header 1 x PMBus connector 1 x IPMB connector 1 x Clear CMOS jumper 1 x BIOS recovery jumper Front Panel LED Buttons 2 x USB 3 0 1 x Power button with LED 1 x ID button with LED 1 x NMI button 1 x Reset button 2 x LAN activity LEDs 1 x HDD activity LED 1 x System status LED Rear Panel I O 2 x USB 3 0 1 x VGA 2 x RJ45 1 x MLAN 1 x...

Страница 15: ...DAP AD RADIUS Support Backup Restore Configuration Remote BIOS BMC CPLD Update Event Log Filter User Management Media Redirection Settings PAM Order Settings SSL Settings SMTP Settings Power Supply 2 x 1200W redundant PSUs 80 PLUS Platinum AC Input 100 240V 12 7A 50 60Hz DC Input 240Vdc 6A DC Output Max 1000W 100 240V 12V 80 5A 12Vsb 3A Max 1200W 200 240V or 240Vdc input 12V 97A 12Vsb 3A Environme...

Страница 16: ...Hardware Installation 16 System Dimension 1U 438mm W x 43 5mm H x 730mm D We reserve the right to make any changes to the product specifications and product related information without prior notice ...

Страница 17: ... 17 Hardware Installation 1 3 System Block Diagram ...

Страница 18: ...Hardware Installation 18 ...

Страница 19: ...No Description 1 Front USB 3 0 ports 2 Front Panel LEDs and buttons 2 1 2 R182 Z91 R182 Z92 1 2 HDD0 HDD2 HDD4 HDD6 HDD8 HDD1 HDD3 HDD5 HDD7 HDD9 No Description 1 Front USB 3 0 ports 2 Front Panel LEDs and buttons Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs ...

Страница 20: ... 5 3 2 1 PSU2 PSU1 No Description 1 PCIe card slot x 2 2 Mezzanine card slot Option OCP 3 0 SFF 3 ID button with LED 4 10 100 1000 Server management LAN port 5 GbE LAN port x 2 6 USB 3 0 port x 2 7 Mezzanine card slot Option OCP 2 0 8 VGA port ...

Страница 21: ...ink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A Off Indicates no HDD access or no HDD error 6 System Status LED Green On Indicates system is operating normally Amber On Indicates a critical condition may include System fan failure System temperature Blink Indicates non critical condition may include Redundant power module failure Temperat...

Страница 22: ...Indicates locating the HDD Blink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A Off Indicates no HDD access or no HDD error 6 System Status LED Green On Indicates system is operating normally Amber On Indicates a critical condition may include System fan failure System temperature Blink Indicates non critical condition may include Redundant ...

Страница 23: ... Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 2 1 ...

Страница 24: ... Blink GREEN Indicates power supply firmware in updating mode Amber Indicates AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Indicates power supply critical event causing shut down failure OCP OVP Fan Fail UVP 0 5Hz Blink Amber Indicates power supply warning events where the power supply continues to operate high temp high power high current slo...

Страница 25: ...emoved HDD Slot LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OFF OFF Rebuilding OFF LED1 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuildin...

Страница 26: ...System Appearance 26 This page left intentionally blank ...

Страница 27: ...ver you are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary...

Страница 28: ...nstructions to remove the chassis cover 1 Remove the screw securing the chassis cover 2 Loosen the thumbscrew securing the chassis cover 3 Push down the indentations located on the sides of the chassis cover 4 Slide the cover cover to the rear of the system and then remove the cover in the direction indicated by the arrow 5 To reinstall the chassis cover reverse steps 1 4 2 3 3 1 4 ...

Страница 29: ...nd Installing the Fan Duct Follow these instructions to remove install the fan duct 1 Lift up to remove the two fan ducts 2 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats ...

Страница 30: ...the fan duct 1 Loosen the captive screws securing the heatsink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To reinstall the heat sink reverse steps 1 2 while ensuring that you tighten the captive screws in sequential order 1g2g3g4 as seen in the image below 2 4 3 1 ...

Страница 31: ...ocedures described in the following sections unless you are a qualified service technician Follow these instructions to install the CPU 1 Loosen the three captive screws securing the CPU cover in sequential order 1 g 2 g 3 2 Flip open the CPU cover 3 Remove the CPU carrier from the CPU frame using the handle on the CPU carrier 4 Using the handle on the CPU carrier insert the new CPU carrier with C...

Страница 32: ...System Hardware Installation 32 CPU 4 5 6 2 3 1 7 ...

Страница 33: ...0 DIMM_P0_D1 DIMM_P1_N0 DIMM_P1_N1 DIMM_P1_M0 DIMM_P1_M1 DIMM_P1_O0 DIMM_P1_O1 DIMM_P1_P0 DIMM_P1_P1 DIMM_P1_K1 DIMM_P1_K0 DIMM_P1_L1 DIMM_P1_L0 DIMM_P1_J1 DIMM_P1_J0 DIMM_P1_I1 DIMM_P1_I0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always tur...

Страница 34: ...herboard Follow these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 5 3 DIMM Population Table RDIMM Maximum Frequency Supported Tablle 2R 2 1 DIMMs Populated DIMM 1R 1 1 ...

Страница 35: ...d Table 1 2 DIMMs Populated DIMM 2S2R 2S4R 1 2 2933 2666 1 2V Frequency MT s NOTE l 1R 1 package rank of SDP DRAMs l 2R 2 package rank of SDP DRAMs l 2DR 2 package rank of DDP DRAMs l 4DR 4 package rank of DDP DRAMs l 2S2R 2S4R 2S8R 2 package rank of 2 4 8 high 3DS DRAMs l DIMM must be populated in sequential alphabetic order starting with bank A l When only one DIMM is used it must be populated i...

Страница 36: ...he PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Loosen the thumbscrew securing the riser bracket to the system 2 Lift up the riser bracket out of system 3 Remove the screw securing the slot cover to the riser bracket 4 Remove the slot covers from the riser bracket 5...

Страница 37: ...ons to install an OCP 3 0 mezzanine card 1 Remove the two screws securing the mezzanine card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 mezzanine card into the card slot ensuring that the card is firmly connected to the connector on the motherboad 4 Tighten the thumbnail screw to secure the OCP 3 0 mezannine card in place 5 Reverse steps 3 4 to replace the OCP 3 0 mezz...

Страница 38: ...ut of system 3 Remove the screw securing the mezzanine card slot cover 4 Remove the slot cover from the system 5 Insert the OCP 2 0 mezzanine card into the compartment ensuring that the card is firmly connected to the connector on the motherboad 6 Secure the OCP 2 0 mezzanine card into the system with three screws 7 Reverse steps 5 6 to replace the OCP 2 0 mezzanine card 1 2 5 6 4 3 ...

Страница 39: ...o the HDD connector on the backplane Follow these instructions to install a 3 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the 3 5 HDD tray 4 Pull the sides of the HDD tray in the direction indicated 5 Slide the hard disk drive into the HDD tray 6 Push the sides of the HDD tray back in the direction indicated ...

Страница 40: ...System Hardware Installation 40 5 6 6 ...

Страница 41: ...ed to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the 2 5 HDD tray 4 Orient the hard disk drive so the opening on the rear of the hard disk drive is aligned to the positioning stud on the HDD tray 5 Slide the hard disk drive into the ...

Страница 42: ... 2 device The stand off screw is pre installed for 22110 cards as standard Refer to the size of the M 2 device and change the position of the stand off screw accordingly Follow these instructions to install the M 2 device and heat sink 1 Insert the M 2 device into the M 2 connector 2 Press down on the M 2 device 3 Install the thermal pad of the M 2 device to the M 2 device 4 Press down on the ther...

Страница 43: ...ware Installation 3 10 Replacing the Fan Assembly Follow these instructions to replace the fan assembly 1 Lift up the fan assembly from the chassis 2 Reverse the previous steps to install the replacement fan assembly ...

Страница 44: ... supply 1 Press the retaining clip on the right side of the power supply along the direction of the arrow 2 Pull up the power supply handle at the same time and pull out the power supply 3 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 3 1 2 ...

Страница 45: ... 45 System Hardware Installation 3 12 Cable Routing 3 12 1 Cable Routing for R182 Z90 Onboard SATA HDD Backplane Board Signal ...

Страница 46: ...System Hardware Installation 46 R182 Z90 HDD Backplane Board Power Front Panel IO ...

Страница 47: ... 47 System Hardware Installation R182 Z90 Front Panel USB ...

Страница 48: ...System Hardware Installation 48 3 12 2 Cable Routing for R182 Z91 Onboard SATA NVME ...

Страница 49: ... 49 System Hardware Installation R182 Z91 HDD Backplane Board Signal HDD Backplane Board Power ...

Страница 50: ...System Hardware Installation 50 R182 Z91 Front Panel IO Front Panel USB ...

Страница 51: ... 51 System Hardware Installation 3 12 3 Cable Routing for R182 Z92 NVMe Card 0 1 NVMe Card 2 3 Top Bo om ...

Страница 52: ...System Hardware Installation 52 R182 Z92 NVMe Card 4 5 NVMe Card 6 7 Top Bo om Bo om Top ...

Страница 53: ... 53 System Hardware Installation R182 Z92 NVMe Card 8 9 HDD Backplane Board Signal ...

Страница 54: ...System Hardware Installation 54 R182 Z92 HDD Backplane Board Power Front Panel IO ...

Страница 55: ... 55 System Hardware Installation R182 Z92 Front Panel USB ...

Страница 56: ...System Hardware Installation 56 This page intentionally left blank ...

Страница 57: ...en4 x16 9 BMC Firmware Readiness LED 10 TPM Module Connector SPI Interface 11 SlimLine SAS Connector SLSAS_0 PCIe SATA Defined by SKUs 21 1 2 3 5 7 8 9 6 4 10 11 12 13 14 18 19 20 21 22 23 24 26 25 15 16 17 CPU1 CPU0 DIMM_P0_H1 DIMM_P0_H0 DIMM_P0_G1 DIMM_P0_G0 DIMM_P0_F1 DIMM_P0_F0 DIMM_P0_E1 DIMM_P0_E0 DIMM_P0_A0 DIMM_P0_A1 DIMM_P0_B0 DIMM_P0_B1 DIMM_P0_C0 DIMM_P0_C1 DIMM_P0_D0 DIMM_P0_D1 DIMM_P1...

Страница 58: ...k Plane Board Power Connector 18 OCP Mezzanine Connector OCP 2 0 Gen3 x8 19 Riser Connector 2 PCIe Gen4 x32 Slot 20 Riser Connector 3 PCIe Gen4 x16 Slot 21 Power Supply Connector 1 Primary 22 Power Supply Connector 2 Secondary 23 SlimLine SAS Connector SLSAS_2 PCIe SATA Defined by SKUs 24 SlimLine SAS Connector SLSAS_3 PCIe SATA Defined by SKUs 25 2 x 7 Pin HDD Back Plane Board Power Connector 26 ...

Страница 59: ...e Normal Default BIOS Defined BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL PMBUS_SEL BIOS_PWD BIOS_RCVR Normal Default J2 1 2 3 4 Clear CMOS CLR_CMOS Enable Default 1 2 3 NCSI Switch 21 Onboard LAN OCP 2 0 Mezzanine OCP 3 0 Mezzanine SW1 OFF SW2 OFF ON ON OFF ON ...

Страница 60: ... caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this chapter ...

Страница 61: ...k main chipset and system event logs Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make...

Страница 62: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 63: ...on number of the BIOS setup utility BIOS Information Project Name Displays the project name information Project Version Displays version number of the BIOS setup utility Build Date and Time Displays the date and time when the BIOS setup utility was created BMC Information BMC Firmware Version Displays version number of the BIOS setup utility Processor Information CPU 0 Brand String CPU 1 Brand Str...

Страница 64: ...ion information Onboard LAN Information LAN1 MAC Address Note2 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format Note1 The number of LAN ports listed will depend on the motherboard system model Note2 This secti...

Страница 65: ... Setup 66 5 2 Advanced Menu The Advanced menu display submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Страница 66: ...figuration Security Device Support Select Enable to activate TPM support feature Options available Enable Disable Default setting is Enable SPI TPM Support Options available Enabled Disabled Default setting is Enabled 5 2 1 Trusted Computing ...

Страница 67: ...BIOS Setup 68 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Страница 68: ... 69 BIOS Setup 5 2 3 Legacy Video Select Parameter Description OnBrd Ext VGA Select Select between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard ...

Страница 69: ...BIOS Setup 70 5 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information ...

Страница 70: ...ngs Change Settings Note2 Select an optimal setting for the Super I O device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ 3 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 ...

Страница 71: ...rom S5 Enable or disable system wake on alarm event Select Fixed Time system will wake on the time HH MM SS specified Select Dynamic Time and the system will wake at the current time plus an increase in minute s Options available Disabled Fixed Time Default setting is Disabled ...

Страница 72: ... the available COM ports Serial Port for Out of Band Management Windows Emergency Management Services EMS Console Redirection Note Selects a COM port for EMS console redirection EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled COM1 SOL COM2 Console Redirecti...

Страница 73: ...with slow devices may require more than 1 stop bit Options available 1 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signal...

Страница 74: ...S Console Redirection Settings Out of Band Mgmt Port Selects a serial port to remotely manage a Windows server OS Options available COM1 SOL COM2 Default setting is COM1 SOL Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is VT UTF8 Bits per second Selects the transfer rate for console redirection Options available...

Страница 75: ...tions available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 Information Press Enter to view more information related to CPU 0 CPU 1 Information Press Enter to view more information related to CPU 1 ...

Страница 76: ...e related PCI E slot Options available Enabled Disabled Default setting is Enabled Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Sett...

Страница 77: ... 78 Parameter Description SR IOV Support If the system has SR IOV capable PCIe devices this item Enable Disable Single Root IO Virtualization Support Options available Enabled Disabled Default setting is Enabled ...

Страница 78: ...ff Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support ...

Страница 79: ...er Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM0 1 00 HDisk0 1 00 Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to ...

Страница 80: ... 81 BIOS Setup 5 2 10 NVMe Configuration Parameter Description NVMe controller and Drive Information Displays the NVMe devices connected to the system ...

Страница 81: ...BIOS Setup 82 5 2 11 SATA Configuration ...

Страница 82: ...lable Enabled Disabled Default setting is Disabled Ipv6 PXE Support Note Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled Ipv6 HTTP Support Note Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled IPSEC Certificate Note Enable Disable the IPSEC Certificate feature PXE boot wait time Note Wait time in ...

Страница 83: ...anced items Channel A BC D E F G H DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode CPU 1 Press Enter for configuration of advanced items Channel I J K L M N O P DIMM0 Presence DIMM1 Presence Chipset Bank Interleave Dram EC Dram Parity Dimm Sensor Fine Grain Mode ...

Страница 84: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Страница 85: ...n Press Enter for configuration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration N A ...

Страница 86: ... 87 BIOS Setup 5 2 16 Intel R I350 Gigabit Network Connection ...

Страница 87: ... Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the Network Interface Controller PCI D...

Страница 88: ... 89 BIOS Setup 5 2 17 VLAN Configuration ...

Страница 89: ...m 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Enable Disable the VLAN Options available Enable Disable Default setting is Disabled Remove VLAN Press Enter to remove an existing VLAN Note Onl...

Страница 90: ...e Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter and then choose to save or discard the changes made Note This item will ap...

Страница 91: ... Table Gateway addresses DNS addresses Interface ID The 64 bit alternative interface ID for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consecutive Neighbor Solicitaion messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Addres Detection is not performed Policy Save Changes...

Страница 92: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Страница 93: ...ber of CCDs to be used the number of cores to be used and whether to enable or disable symmetric multithreading Prefetcher settings Press Enter for more options L1 Stream HW Prefetcher Option to enable or disable L1 Stream HW Prefetcher Options available Disable Enable Auto Default option is Auto L2 Stream HW Prefetcher Option to enable or disable L2 Stream HW Prefetcher Options available Disable ...

Страница 94: ...ount This field specifies the max valid ASID which affects the maximum system physical address space 16TB of physical address space is available for systems that support 253 ASIDs while 8TB of physical address space is available for systems that support 509 ASIDs Options available 253 ASIDs 509 ASIDs Auto Default option is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs O...

Страница 95: ...s expected breakpoint redirect capability compromised Silver workaround DbReq PDM and breakpoint redirect function as expected SCAN capability compromised Options available Auto No Workaround Bronze Workaround Silver Workaround Default option is Auto PPIN Opt in Turns on PPIN feature Options available Disabled Enabled Auto Default option is Auto ...

Страница 96: ...s 48 hours Auto Default option is Auto Poison scrubber control Allows you to enable or disable poison scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber control Allows you to enable or disable redirect of scrubber control Options available Disabled Enabled Auto Default option is Auto Redirect scrubber limit Allows you to set the redirect scrubber limi...

Страница 97: ... to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Do not remap Attempt to remap Auto Default option is Auto DRAM map inversion Inverting the map will cause the highest memory channels to get assigned the lowest addresses in the system Options available Disabl...

Страница 98: ... UMC downstream slaves Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Disable DF sync flood propagation Enable Disable DF SyncFlood Options avaialble Sync flood disabled Sync flood enabled Auto Default option is Auto Freeze DF module queues on error Controls DF PIE Config Disabling this options sets DF PIEConfig Options available Disable Enable Auto Default op...

Страница 99: ...bles enforcement of POR restrictions for DDR4 frequency and voltage programming DRAM Controller Configuration Press Enter to configure DRAM controller options CAD Bus Configuration Press Enter to configure CAD Bus options Data Bus configuration Press Enter to configure Data Bus options Common RAS Press Enter to configure Common RAS options Security Press Enter to configure UMC security options ...

Страница 100: ...tion is Auto Address Hash Bank Enable or disable bank address hashing Options available Disabled Enabled Auto Default option is Auto Address Hash CS Enable or disable CS address hashing Options available Auto Enabled Disabled Default option is Auto Address Hash Rm Enable or disable RM address hashing Options available Auto Enabled Disabled Default option is Auto SPD Read Optimization Enable or dis...

Страница 101: ...s available Enable Disabled Auto Default option is Auto PCIe ARI Support Enables Alternative Routing ID Interpretation Options available Disable Enable Auto Default option is Auto PCIe Ten Bit Tag Support Enables PCIe ten bit tags for supported devices Auto Disabled Options available Disable Enable Auto Default option is Auto HD Audio Enable Enables or disables HD Audio Options available Enable Di...

Страница 102: ...power efficiency optimized CCLK DPM settings Options available Auto Enabled Default option is Auto Package Power Limit Control Auto Use the fused PPT Manual User can set PPT PPT will be used as the ASIC power limit Options available Manual Auto Default option is Manual xGMI Link Width Control Auto Use degault xGMI link width controller Manual User can set custom xGMI link width controller settings...

Страница 103: ...d to APML When set to FALSE that reporting will be disabled Options available Enabled Disabled Default option is Disabled Egress Poison Mask High Enter a value These set the enable mask for masking of errors logged in EGRESS_POISON_STATUS For each bit set to 1 errors are masked For each bit set to 0 errors trigger response actions Egress Poison Mask Low Enter a value These set the enable mask for ...

Страница 104: ...erted to Okay responses Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default option is Log Errors in MCA Log Poison Data from SLINK This value specifies whether poison data propogated from SLINK will generate a deferred error When this value is set to TRUE deferred errors are enabled When set to FALSE errors are not generated Options available Enabled Disabled Default option i...

Страница 105: ...able AER Cap Enables Advanced Error Reporting Capabilty Options available Enable Disabled Auto Default option is Auto Early Link Speed Sets Early Link Speed Options available Auto Gen1 Gen2 Default option is Auto Hot Plug Handling mode Controls the Hot Plug Handling mode Options available A0 Mode OS First No Error Handling OS First Error Handling Not Implementd Firmware First Not Implemented Auto ...

Страница 106: ...e or disable SATA RAS support Options available Disabled Enabled Auto Default setting is Auto Sata Disabled AHCI Prefetch Function Enable or disable Sata Disabled AHCI Prefetch Function Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 0 Options available Disabled Enabled Auto Default setting is Auto Aggressive SATA Device Sleep Port 1 Options availa...

Страница 107: ...oss Control Select AC Loss Control Method Options available Power Off Power On Last State Default setting is Last State I2C Configuration Options Press Enter for more options I2C 0 1 2 3 4 5 Enable Enable or disable I2C 0 1 2 3 4 5 Options available Disabled Enabled Auto Default setting is Auto Uart Configuration Options Press Enter for more options Uart 0 Enable Uart 0 has no HW FC if Uart 2 is e...

Страница 108: ...ill select MS driver for SD selections Options available AMD eMMC Driver MS Driver Auto Default setting is Auto D3 Cold Support Options available Disabled Enabled Auto Default setting is Auto eMMC Boot Options available Disabled Enabled Auto Default setting is Auto FCH RAS Options Press Enter for more options ALink RAS Support Options available Disabled Enabled Auto Default setting is Auto Reset a...

Страница 109: ...BIOS Setup 110 5 3 6 NTB Common Options Parameter Description NTB Common Options NTB Enable Enable or disable OnChip SATA controller Options available Auto Enable Default setting is Auto ...

Страница 110: ...l Parameter Description Soc Miscellaneous Control ABL Console Out Control Enable Enable ConsoleOut Function for ABL Disable Disable ConsoleOut Function for ABL Auto Keep default behavior Options available Disable Enable Auto Default setting is Auto ...

Страница 111: ...g the function of AMD PBS Select a submenu item then press Enter to access the related submenu screen Parameter Description AMD PBS RAS Press Enter for advanced configurations SPI Locking Enable or disable SPI Locking for protect ROM part Options Available Enabled Disabled Default option is Disabled ...

Страница 112: ...ue is 1000 dec SMI Scale Unit Defines the unit of time scale Options available millisecond second minute Default option is millisecond SMI Period Enter a value Defines the polling interval in milliseconds Default option is 1000 dec Maximum value is 32767 dec 0 disable GHES Notify Type Notification type for deferred corrected errors Options Available Polled SCI Default option is Polled GHES UnCorr ...

Страница 113: ...Device UnCorr Err Mask Reg Enter a value Intialize the PCIe AER Uncorrected Error Mask register of PCIe Device PCIe Device UnCorr Error Sev Reg Enter a value Intialize the PCIe AER Uncorrected Error Severity registers of PCIe Device CCIX GHES Deferred Err Notify Type Notification type for CCIX deferred errors Options Available Polled SCI Default option is Polled CCIX GHES Corrected Err Notify Type...

Страница 114: ...reen Parameter Description PCIe Link Training Type PCIe Link training in 1 or 2 steps Options available 1 Step 2Step Default setting is 1 Step PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enables or disables program all VR on MB Options available Disabled Enabled Default setting is Enabled North Bridge Press Enter for more information on the North Bridge ...

Страница 115: ...Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configure OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes NOTE This item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy Configure OS Watchdog Timer Policy Options available Rese...

Страница 116: ...Parameter Description View FRU Information Press Enter to view the advanced items BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 117: ...sing SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options avail...

Страница 118: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 119: ...BMC network parameters during BIOS phase Options available Unspecified Static DynamicBmcDhcp Default setting is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time synchronize BMC network parameter values Press En...

Страница 120: ...C network during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 ...

Страница 121: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 122: ...es being loaded before Windows loads and gets to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options available Standard Custom Default setting is Custom Restore Factory Keys Forces the system to...

Страница 123: ...splays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set Update Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set Update Append Forbidden Signature...

Страница 124: ...put the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is On Quiet Boot Enable Disable showing the logo during POST Options available Disabled Enabled Default setting is Enabled Boot mode select Selects the boot mode Options available LEGACY UEFI Default setting is UEFI FIXED BOOT ORDER Priorities Boot Option 1 2 3 4 5 Press ...

Страница 125: ...BIOS Setup 126 Parameter Description UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 126: ...orities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 127: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 128: ... so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options available ...

Страница 129: ...ce 0xE00D ProcMemPhyFenceTraining 0xE00E ProcMemSynchronizeDcts 0xE00F ProcMemSystemMemoryMapping 0xE010 ProcMemMtrrConfiguration 0xE011 ProcMemDramTraining 0xE012 ProcMemBeforeAnyTraining Public interface 0xE013 5 10 3 PMU Test Points ABL Mem PMU Before PMU Firmware load 0xE014 ABL Mem PMU After PMU Firmware load 0xE015 ABL Mem PMU Populate SRAM Timing 0xE016 ABL Mem PMU Populate SRAM Config 0xE0...

Страница 130: ... ABL Mem Read Test pattern 0xE036 ABL Mem Compare Test pattern 0xE037 ABL Mem Online Spare init 0xE038 ABL Mem Chip select Interleave Init 0xE039 ABL Mem Node Interleave Init 0xE03A ABL Mem Channel Interleave Init 0xE03B ABL Mem ECC initialization 0xE03C ABL Mem Platform Specific Init 0xE03D ABL Mem Before callout for AgesaReadSpd 0xE03E ABL Mem After callout for AgesaReadSpd 0xE03F ABL Mem Before...

Страница 131: ... init 0xE057 Exit point CPU APOB EDC info init 0xE058 5 10 6 Topology test points ProcTopologyEntry 0xE071 ProcTopologyDone 0xE07C 5 10 7 Extended memory test point ProcMemSendMRS2 0xE080 Sedding MRS3 0xE081 Sending MRS1 0xE082 Sending MRS0 0xE083 Continuous Pattern Read 0xE084 Continuous Pattern Write 0xE085 Mem 2d RdDqs Training begin 0xE086 Mem Before optional callout to platform BIOS to change...

Страница 132: ...de 0xE09F TP0xA0 0xE0A0 GNB internal debug code 0xE0A1 GNB internal debug code 0xE0A2 GNB internal debug code 0xE0A3 GNB internal debug code 0xE0A4 GNB internal debug code 0xE0A5 GNB internal debug code 0xE0A6 GNB internal debug code 0xE0A7 GNB internal debug code 0xE0A8 GNB internal debug code 0xE0A9 GNB internal debug code 0xE0AA GNB internal debug code 0xE0AB GNB internal debug code 0xE0AC GNB ...

Страница 133: ...Initialization Stage 4 Warning 0xF4C0 ABL 3 GMI xGMI Initialization Stage 4 Error 0xE5C0 ABL 3 GMI xGMI Initialization Stage 5 0xB5C0 ABL 3 GMI xGMI Initialization Stage 5 Warning 0xF5C0 ABL 3 GMI xGMI Initialization Stage 5 Error 0xE6C0 ABL 3 GMI xGMI Initialization Stage 6 0xB6C0 ABL 3 GMI xGMI Initialization Stage 6 Warning 0xF6C0 ABL 3 GMI xGMI Initialization Stage 6 Error 0xE7C0 ABL 3 GMI xGM...

Страница 134: ...n AP 0xE0E0 Before IDS calls out to get IDS data 0xE0E1 After IDS calls out to get IDS data 0xE0E2 Before the heap manager calls out to allocate a buffer 0xE0E3 After the heap manager calls out to allocate a buffer 0xE0E4 Before the heap manager calls out to deallocate a buffer 0xE0E5 After the heap manager calls out to deallocate a buffer 0xE0E6 Before the heap manager calls out to locate a buffe...

Страница 135: ... Initialization 0xE103 End of phase 1b memory code 0xE104 ABL 1b memory initialization 0xE105 ABL 6 Global memroy error detected 0xE106 ABL 1b Debug Synchronization Function 0xE107 ABL 4b Debug Synchronization Function 0xE108 AblbBegin 0xE109 Ab4bBegin 0xE10A BSP encountered HMAC fail on APOB Header 0xE10B ABL Eroor General ASSERT 0xE2A0 Unknown Error 0xE2A1 ABL Error Log Inig Error 0xE2A2 ABL Err...

Страница 136: ...r DDR Recovery error 0xE2BE ABL Error for RRW Test error 0xE2BF ABL Error for On Die Thermal error 0xE2C1 ABL Error for Heap Allocation For Dct Struct Amd Ch Def structure error 0xE2C2 ABL Error for Heap Allocation for PMU SRAM Msg block error 0xE2C3 ABL Error for Heap Phy PLL lock Flure error 0xE2C4 ABL Error for Pmu Training error 0xE2C5 ABL Error for Failure to Load or Verify PMU FW error 0xE2C...

Страница 137: ... Error 0xE2EB ABL Error MBIST Heap Allocation Error 0xE2EC ABL Error MBIST Results Error 0xE2EE ABL Error NO Dimm Smcus Info Error 0xE2EE ABL Error Por Max Freq Table Error 0xE2EF ABL Error Unsupproted DIMM Config Error 0xE2F0 ABL Error No Ps Table Error 0xE2F1 ABL Error Cad Bus Timing Not Found Error 0xE2F2 ABL Error Data Bus Timing Not Found Error 0xE2F3 ABL Error LrDIMM IBT Not Found Error 0xE2...

Страница 138: ...E30A ABL Error message slave sync function execution Error 0xE30B ABL Error slave offline Error 0xE30C ABL Error Sync Master Error 0xE30D ABL Error Slave Informs Master Info Message Error 0xE30E ABL Error General Assert Error 0xE30F ABL Error No Dimms On Any Channel in sysem 0xE310 ABL Alert PMU Major Message captured 0xE311 ABL Alert PMU REsults Rx Timing captured 0xE312 ABL Alert PMU REsults Tx ...

Страница 139: ...A107 TpProcMemSpdTiming 0xA108 TpProcMemDramMapping 0xA109 TpProcMemPlatformSpecificConfig 0xA10A TPProcMemPhyCompensation 0xA10B TpProcMemStartDcts 0xA10C Public interface 0xA10D TpProcMemPhyFenceTraining 0xA10E TpProcMemSynchronizeDcts 0xA10F TpProcMemSystemMemoryMapping 0xA110 TpProcMemMtrrConfiguration 0xA111 TpProcMemDramTraining 0xA112 Public interface 0xA113 TpProcMemWriteLevelizationTraini...

Страница 140: ...2 Start sweep 0xA133 Set delay 0xA134 Write test pattern 0xA135 Read Test pattern 0xA136 Compare Test pattern 0xA137 Online Spare init 0xA138 Bank Interleave Init 0xA139 Node Interleave Init 0xA13A Channel Interleave Init 0xA13B ECC initialization 0xA13C Platform Specific Init 0xA13D Before callout for AgesaReadSpd 0xA13E After callout for AgesaReadSpd 0xA13F Before optional callout AgesaHookBefor...

Страница 141: ...xA187 Mem After optional callout to platform BIOS to change External Vref during 2d Training 0xA188 Configure DCT For General use begin 0xA189 Configure DCT For training begin 0xA18A Configure DCT For Non Explicit 0xA18B Configure to Sync channels 0xA18C Allocate C6 Storage 0xA18D Before LV DDR4 0xA18E BR CPU BR before AP launch 0xA190 Install AP launched PPI 0xA191 BR after AP launch 0xA192 Befor...

Страница 142: ... code calls out to locate a buffer 0xA1F2 After the memory code calls out to locate a buffer 0xA1F3 Before the memory code calls out to locate a buffer 0xA1F4 After the memory code calls out to locate a buffer 0xA1F5 Before the memory code calls out to locate a buffer 0xA1F6 After the memory code calls out to locate a buffer 0xA1F7 5 11 4 PMU Post Code Failed PMU training 0xA1F9 5 11 5 0xA5XX assi...

Страница 143: ...eV2 ready to boot exit 0xA52A PspDxeV2 exit boot serivce entry 0xA52B PspDxeV2 exit boot serivce exit 0xA52C PspSmmV2 entry 0xA52D PspSmmV2 exit 0xA52E PspSmmV2 SwSmiCallBack entry build the S3 save area for resume 0xA52F PspSmmV2 SwSmiCallBack exit build the S3 save area for resume 0xA530 PspSmmV2 BspSmmResumeVector entry 0xA531 PspSmmV2 BspSmmResumeVector exit 0xA532 PspSmmV2 ApSmmResumeVector e...

Страница 144: ...mand MboxBiosCmdHSTIQuery 0xA5C4 Before send C2P command MboxBiosCmdClrSmmLock 0xA5C7 Before send C2P command MboxBiosCmdPcieInfo 0xA5C8 Before send C2P command MboxBiosCmdGetVersion 0xA5C9 PSP C2P mailbox exit base 0xA5DX Cmd 0xA5D0 Wait C2P command MboxBiosCmdDramInfo finished 0xA5D1 Wait C2P command MboxBiosCmdSmmInfo finished 0xA5D2 Wait C2P command MboxBiosCmdSleep SxInfo finished 0xA5D3 Wait...

Страница 145: ...t 0xA90B IOMMU AmdNbioIommu DXE driver entry 0xA90C AmdNbioIommu DXE driver exit 0xA90D ALIB AmdNbioALIB DXE driver entry 0xA90E AmdNbioALIB DXE driver exit 0xA90F SMU AmdSmuV8 PEIM driver entry 0xA910 AmdSmuV8 PEIM driver exit 0xA911 AmdSmuV8 DXE driver entry 0xA912 AmdSmuV8 DXE driver exit 0xA913 AmdSmuV9 PEIM driver entry 0xA914 AmdSmuV9 PEIM driver exit 0xA915 AmdSmuV9 DXE driver entry 0xA916 ...

Страница 146: ... NbioBaseHookReadyToBoot Event exit 0xA95D NbioBaseHookPciIO Event entry 0xA95E NbioBaseHookPciIO Event exit 0xA95F 0xA980 0xA99F BR GNB Task GnbEarlyInterfaceCZ entry 0xA970 GnbEarlyInterfaceCZ exit 0xA971 PcieConfigurationInit entry 0xA972 PcieConfigurationInit exit 0xA973 GnbEarlierInterfaceCZ entry 0xA974 GnbEarlierInterfaceCZ exit 0xA975 PcieEarlyInterfaceCZ entry 0xA976 PcieEarlyInterfaceCZ ...

Страница 147: ...Late exit 0xA993 GnbSmuServiceRequestV8 entry 0xA994 GnbSmuServiceRequestV8 exit 0xA995 5 11 7 0xACXX assigned for AGESA CCX Module CCX IDS IDS_HOOK_CCX_AFTER_AP_LAUNCH 0xAC10 CCX PEI entry 0xAC50 CCX downcore entry 0xAC51 CCX DXE entry 0xAC55 CCX MP service callback entry 0xAC56 CCX Read To Boot callback entry 0xAC57 CCX SMM entry 0xAC5D CCX PEI start to launch APs for S3 0xAC70 CCX PEI end of la...

Страница 148: ...ch finished 0xAF0D FCH InitS3Late dispatch finished 0xAF0E FCH Pei Entry 0xAF10 FCH Pei Exit 0xAF11 FCH MultiFch Pei Entry 0xAF12 FCH MultiFch Pei Exit 0xAF13 FCH Dxe Entry 0xAF14 FCH Dxe Exit 0xAF15 FCH MultiFch Dxe Entry 0xAF16 FCH MultiFch Dxe Exit 0xAF17 FCH Smm Entry 0xAF18 FCH Smm Exit 0xAF19 FCH Smm Dispatcher Entry 0xAF20 FCH Smm Dispatcher Exit 0xAF21 FCH InitReset HwAcpi 0xAF40 FCH InitR...

Страница 149: ...0xAF61 FCH InitMid LPC 0xAF62 FCH InitMid SPI 0xAF63 FCH InitMid eSPI 0xAF64 FCH InitMid SD 0xAF65 FCH InitMid eMMC 0xAF66 FCH InitMid SATA 0xAF67 FCH InitMid USB 0xAF68 FCH InitMid xGbE 0xAF69 FCH InitLate HwAcpi 0xAF70 FCH InitLate AB Link 0xAF71 FCH InitLate LPC 0xAF72 FCH InitLate SPI 0xAF73 FCH InitLate eSPI 0xAF74 FCH InitLate SD 0xAF75 FCH InitLate eMMC 0xAF76 FCH InitLate SATA 0xAF77 FCH I...

Страница 150: ...PL was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 12 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource ...

Страница 151: ... block can be used to restore the BIOS to a working state To restore your BIOS please follow the instructions listed below Recovery Instruction 1 Change xxx ROM to amiboot rom 2 Copy amiboot rom and AFUDOS exe to USB diskette 3 Setting BIOS Recovery jump to enabled status 4 Boot into BIOS recovery 5 Run Proceed with flash update 6 BIOS update ...

Отзывы: