background image

- 8 -

5-2-3  Legacy Video Select ...............................................................................................51

5-2-4  AST2500 Super IO Configuration

 ...........................................................................52

5-2-5  S5 RTC Wake Settings ...........................................................................................55
5-2-6  Serial Port Console Redirection .............................................................................56

5-2-7  CPU Configuration

 ..................................................................................................60

5-2-8  PCI Subsystem Settings .........................................................................................61

5-2-9  USB Configuration

 ..................................................................................................63

5-2-10  Network Stack Configuration

 ..................................................................................65

5-2-11  NVMe Configuration

 ...............................................................................................66

5-2-12  SATA Configuration

.................................................................................................67

5-2-13  Graphic Output Configuration

 .................................................................................68

5-2-14  AMD Mem Configuration Status

 .............................................................................69

5-2-15  Tls Auth Configuration

 ............................................................................................70

5-2-16  ISCSI Configuration

 ................................................................................................71

5-2-17  Intel(R) I350 Gigabit Network Connection ..............................................................72

5-2-18  VLAN Configuration

 ................................................................................................74

5-2-19  MAC IPv4 Network Configuration

 ...........................................................................75

5-2-20  MAC IPv6 Network Configuration

 ...........................................................................76

5-3  AMD CBS Menu ............................................................................................. 77

5-3-1  CPU Common Options ...........................................................................................78
5-3-2  DF Common Options ..............................................................................................84
5-3-3  UMC Common Options ..........................................................................................89
5-3-4  NBIO Common Options ........................................................................................104
5-3-5  FCH Common Options .........................................................................................110
5-3-6  SOC Miscellaneous Control .................................................................................114
5-3-7  Workload Tuning ...................................................................................................115

5-4  AMD PBS Menu ........................................................................................... 116

5-4-1 RAS ......................................................................................................................117

5-5  Chipset Setup Menu ..................................................................................... 119

5-5-1  North Bridge .........................................................................................................120
5-5-2  Fabric Resource ...................................................................................................121

5-6  Server Management Menu ........................................................................... 122

5-6-1  System Event Log ................................................................................................124
5-6-2  View FRU Information ..........................................................................................125

5-6-3  BMC Network Configuration

 .................................................................................126

5-6-4  IPv6 BMC Network Configuration

 .........................................................................127

5-7  Security Menu .............................................................................................. 128

5-7-1  Secure Boot  .........................................................................................................129

5-8  Boot Menu .................................................................................................... 131

5-8-1  UEFI NETWORK Drive BBS Priorities  ................................................................133
5-8-2  UEFI Application Boot Priorities

  ................................................................. 134

Содержание G262-ZR0

Страница 1: ...G262 ZR0 HPC Server 2U DP SXM4 A100 4 GPU Server User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ...here the cord extends from the server WARNING To reduce the risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is intended to be used in Restrict Access Location The access can only be gained ...

Страница 5: ...scharge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully The...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...ng the Fan Duct 25 3 3 Removing the Heat Sink 26 3 4 Installing the CPU 27 3 5 Installing Memory 28 3 5 1 Eight Channel Memory Configuration 28 3 5 2 Installing the Memory 29 3 5 3 Processor and Memory Module Matrix Table 29 3 5 4 DIMM Population Table 30 3 6 Installing the PCI Expansion Card 31 3 7 Replacing the System FAN Module 32 3 8 Installing the Hard Disk Drive 33 3 9 Removing and Installin...

Страница 8: ...tion 74 5 2 19 MAC IPv4 Network Configuration 75 5 2 20 MAC IPv6 Network Configuration 76 5 3 AMD CBS Menu 77 5 3 1 CPU Common Options 78 5 3 2 DF Common Options 84 5 3 3 UMC Common Options 89 5 3 4 NBIO Common Options 104 5 3 5 FCH Common Options 110 5 3 6 SOC Miscellaneous Control 114 5 3 7 Workload Tuning 115 5 4 AMD PBS Menu 116 5 4 1 RAS 117 5 5 Chipset Setup Menu 119 5 5 1 North Bridge 120 5...

Страница 9: ... 9 5 9 Save Exit Menu 135 5 10 BIOS POST Beep code AMI standard 136 5 10 1 PEI Beep Codes 136 5 10 2 DXE Beep Codes 136 ...

Страница 10: ... 10 This page intentionally left blank ...

Страница 11: ... dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loca...

Страница 12: ...nel memory per processor architecture RDIMM modules up to 128GB supported LRDIMM modules up to 128GB supported 3DS RDIMM LRDIMM modules up to 256GB supported Memory speed Up to 3200 2933 MHz Socket cket Security Security Server Operating Properties Power Supply LAN Front side 2 x 1GbE LAN ports 1 x Intel I350 AM2 1 x 10 100 1000 management LAN Socket Socket Security Security Server Operating Prope...

Страница 13: ...TP072 M key PCIe Gen4 x4 Supports NGFF 2242 2260 2280 22110 cards Socket Socket Security Security Server Operating Properties Power Supply Internal I O 1 x TPM header 1 x Front panel header Socket Socket Security Security Server Operating Properties Power Supply Front I O 2 x USB 3 0 1 x mini DP 2 x RJ45 1 x MLAN 1 x Power button with LED 1 x ID button with LED 1 x Reset button 1 x System status L...

Страница 14: ... cket Security Security Server Operating Properties Power Supply System Management Aspeed AST2500 management controller AMI MegaRAC SP X Solution web interface Dashboard HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile System Firewall Power Consumption Power C...

Страница 15: ...y Operating Properties Operating temperature 10 C to 35 C Operating humidity 8 80 non condensing Non operating temperature 40 C to 60 C Non operating humidity 20 95 non condensing Socket Socket Security Security Server Operating Properties Power Supply System Dimension 2U 448 W x 86 8 H x 800 D mm ...

Страница 16: ...Hardware Installation 16 1 3 System Block Diagram ...

Страница 17: ... Front Panel LEDs and Buttons 2 PCIe Card Slot 3 PCIe Card Slot 4 Mini DP Port 5 USB 3 0 Port x 2 6 GbE LAN Port x 2 7 10 100 1000 Server Management LAN Port 8 Mezzanine Card Slot Option OCP3 The Green HDD Latches Support NVMe Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs ...

Страница 18: ...System Appearance 18 2 2 Rear View PSU1 PSU2 PCIe 2 PCIe 1 PCIe 3 PCIe 4 1 No Description 1 Full Height Half Length PCIe Card Slot x 4 ...

Страница 19: ...g the HDD Blink Indicates accessing the HDD Amber On Indicates HDD error Green Amber Blink Indicates HDD rebuilding N A Off Indicates no HDD access or no HDD error 4 ID Button Press the button to activate system identification 5 System Status LED Green On Indicates system is operating normally Amber On Indicates a critical condition may include System fan failure System temperature Blink Indicates...

Страница 20: ... Speed LED Yellow On 1 Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring 1 2 1 2 1 2 ...

Страница 21: ...ode Green 2Hz Blinking Power supply firmware updating mode Amber On AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP Amber 1Hz Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Страница 22: ...DD Slot LED on Back Panel Disk LED Removed HDD Slot Green ON 1 OFF BLINK 2 BLINK 2 OFF OFF OFF ON OFF ON 1 OFF OFF ON OFF ON Low Speed 2 Hz 3 3 OFF OFF Green Amber Green ON 1 OFF Green OFF OFF Amber Amber OFF OFF Rebuilding OFF LED1 LED 2 HDD Present No HDD Green ON OFF NOTE 1 Depends on HBA Utility Spec 2 Blink cycle depends on HDD s activity signal 3 If HDD is pulled out during rebuilding the di...

Страница 23: ...er you are working inside the system case If possible wear a grounded wrist strap when you are working inside the system case Alternatively discharge any static electricity by touching the bare metal system of the system case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do ...

Страница 24: ...d to AC power Follow these instructions to remove the top rear cover 1 Remove the two screws on the sides of the top cover 2 Unlock the plastic handle and pull the grip handle to open the panel cover 3 Slide the cover to the rear of the system and then remove the cover in the direction indicated by the arrow 4 To reinstall the chassis cover reverse steps 1 3 3 1 2 ...

Страница 25: ...ct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 2 1 1 3 CPU Fan Duct 1 Remove the screws securing the bracket 2 Lift up to remove the bracket 3 Lift up and remove the fan duct 4 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 1 2 3 3 2 Removing and Installing the...

Страница 26: ...sink 1 Loosen the captive screws securing the heatsink in place in reverse order 4g3g2g1 2 Lift and remove the heat sink from the system 3 To reinstall the heat sink reverse steps 1 2 while ensuring that you tighten the captive screws in sequential order 1g2g3g4 as seen in the image below 2 2 4 4 1 1 3 3 ...

Страница 27: ...nician Follow these instructions to install the CPU 1 Loosen the three captive screws in sequential order 1g2g3 securing the CPU cover 2 Flip open the CPU cover 3 Remove the CPU cap with CPU from the CPU frame using the handle on the CPU cap 4 Using the handle on the CPU cap insert the new CPU cap with CPU installed into the CPU frame NOTE Ensure the CPU is installed in the CPU cap in the correct ...

Страница 28: ...o install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from the power outlet before installing the memory to prevent hardware damage Memory modules have a foolproof design A memory module can be installed in only one direction If you are unable to...

Страница 29: ...these instructions to install the Memory 1 Insert the DIMM memory module vertically into the DIMM slot and push it down 2 Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 Processor and Memory Module Matrix Table 8 DIMMs CPU CPU0 A0 B0 C0 D0 E0 F0 G0 H0 16 DIMMs CPU0 A0 B0 C0 D0 E0 F0 G0 H0 ...

Страница 30: ...ks 3200 LRDIMM 4DR 4 Ranks 3200 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 3DS 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 DIMM Type DIMM Population Max EPYC 7003 DDR Frequency MHz DIMM 0 DIMM 1 RDIMM 1R 3200 1R 1R 2933 2R or 2DR 3200 1R 2R or 2DR 2933 2R or 2DR 2R or 2DR 2933 LRDIMM 4DR 3200 4DR 4DR 2933 2S2R 4 Ranks 3200 2S4R 8 Ranks 3200 2S2R 4 Ranks 2S2R 4 Ranks 2933 2S4R 8 Ranks 2S4R 8 Ranks 2933 3DS 2S2R 4...

Страница 31: ... riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the screw securing the riser bracket Lift up the riser bracket out of system 2 Loosen and remove the screw securing the slot cover from riser bracket 3 Orient the PCIe card with the riser guide slot and push in the di...

Страница 32: ...to the AC power Disconnect all necessary cable connections Failure to observe these warnings could result in personal injury or damage to the equipment Follow these instructions to replace the system fan module For all system fan modules 1 Grasp the finger slots of the fan module and pull up to remove the fan module 2 Reverse the previous steps to install the replacement fan module 2 2 1 1 ...

Страница 33: ... is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever in the direction indicated to remove the 2 5 HDD tray 4 Orient the hard disk drive so the opening on the rear of the hard disk drive is aligned to the positioning stud on the HDD tray 5 Slide the hard disk driv...

Страница 34: ...he power supply in the direction indicated 3 Pull out the power supply using the handle 4 Insert the replacement power supply firmly into the chassis Connect the AC power cord to the replacement power supply 1 3 2 4 CAUTION In order to reduce the risk of injury from electric shock disconnect AC power from the power supply before removing the power supply from the system Please see Section 2 2 Rear...

Страница 35: ... 35 System Hardware Installation 3 10 Cable Routing Front Switch Cable Front LED Cable GPU Power Cable ...

Страница 36: ...System Hardware Installation 36 HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable ...

Страница 37: ... 37 System Hardware Installation HDD Back Panel Board NVMe Signal Cable ...

Страница 38: ...System Hardware Installation 38 PCIe Signal Cable ...

Страница 39: ... 39 System Hardware Installation System Power Cable Power Supply Signal Cable ...

Страница 40: ...System Hardware Installation 40 On Board SATA Cable ...

Страница 41: ...B 3 0 Port x 2 8 Mini DP Port 9 Serial Port Cable Connector 10 M 2 Connector PCIe x4 Supports NGFF 22110 11 IPMB Connector 12 Proprietary PCIe Slot L Gen 4 x8 slot GENZ_L 13 SlimLine SAS Connector SL4_SATA0 PCIe SATA 14 Power PCIe SATA Connector 15 Power PCIe SATA Connector 16 Power PCIe SATA Connector 17 SGPIO Connector B 18 SGPIO Connector A 19 Proprietary PCIe Slot R Gen 4 x16 slot GENZ_R 20 Pr...

Страница 42: ...1 21 21 3 ON BIOS recovery mode Normal Default BIOS Defined Clear supervisor password OFF HOST_SMBUS_SEL NA NA BIOS_PWD BIOS_RCVR Normal Default J1 1 2 3 4 Clear CMOS CLR_CMOS Enable Default 1 2 3 NCSI Switch 21 Onboard LAN OCP 3 0 Mezzanine OFF ON ...

Страница 43: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 44: ...f the North Bridge Server Management Server additional features enabled disabled setup menus Security Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This...

Страница 45: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 46: ...e of the installed memory Memory Frequency Note3 Displays the frequency information of the installed memory VR Information Version Displays VR version information AGESA PI Version PI Version Displays AGESA PI version information Onboard LAN Information LAN1 MAC Address Note1 Displays LAN MAC address information LAN2 MAC Address Note2 Displays LAN MAC address information System Date Sets the date f...

Страница 47: ... Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen When Boot Mode Select is set to UEFI Default ...

Страница 48: ...BIOS Setup 48 When Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 49: ...ble BIOS support for security device OS will not show security device TCG EFI protocol and INT1A interface will not be available Options available Enable Disable Default setting is Enable SPI TPM Support Select Enable to activate TPM support feature Options available Enabled Disabled Default setting is Enabled ...

Страница 50: ...BIOS Setup 50 5 2 2 PSP Firmware Versions The PSP Firmware Versions page displays the basic PSP firmware version information Items on this window are non configurable ...

Страница 51: ...OnBrd Ext VGA Select Note Selects between onboard or external VGA support Options available Auto Onboard External Default setting is Onboard Note This configurable option will be displayed when Boot Mode Select is set to Legacy in the Boot Boot Mode Select section ...

Страница 52: ... 2 4 AST2500 Super IO Configuration Parameter Description AST2500 Super IO Configuration Super IO Chip Displays the super IO chip information Serial Port 1 Configuration Press Enter for configuration of advanced items ...

Страница 53: ... 53 BIOS Setup 5 2 4 1 Serial Port 1 Configuration ...

Страница 54: ...evices Settings Note2 Displays the Serial Port 1 2 device settings Change Settings Note2 Select an optimal settings for Super IO Device Options available for Serial Port 1 Auto IO 3F8h IRQ 4 IO 3F8h IRQ 3 4 5 6 7 9 10 11 12 IO 2F8h IRQ 3 4 5 6 7 9 10 11 12 IO 3E8h IRQ 3 4 5 6 7 9 10 11 12 IO 2E8h IRQ 3 4 5 6 7 9 10 11 12 Default setting is Auto Options available for Serial Port 2 Auto IO 2F8h IRQ ...

Страница 55: ...tion Wake System from S5 Note1 Enable Disable system wake on alarm event Options available Disabled Fixed Time When Fixed Time enabled system will wake on the hr min sec specified Default setting is Disabled Note1 Advanced items prompt when this item is defined ...

Страница 56: ...r LAN Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when COM1 Serial Over LAN COM2 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is ANSI Bits per second Selects the transfer rate for console redirection Options...

Страница 57: ... 2 Default setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT U...

Страница 58: ...MS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item is configurable when Serial Port for Out of Band Mana...

Страница 59: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 60: ...the CPU Virtualization Options available Enabled Disabled Default setting is Enabled SMEE Controls the Secure Memory Encryption Enable SMEE function Options available Enabled Disabled Default setting is Enabled CPU 0 1 Information Press Enter to view more information related to CPU0 1 ...

Страница 61: ... 61 BIOS Setup 5 2 8 PCI Subsystem Settings ...

Страница 62: ...efault setting is Auto Onboard LAN Controller Note2 Enable Disable the onboard LAN devices Options available Enabled Disabled Default setting is Enabled Onboard LAN I O ROM Note2 Enable Disable the onboard LAN devices and initializes device expansion ROM Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4...

Страница 63: ...ble Auto Enabled Disabled Default setting is Enabled XHCI Hand off Enable Disable the XHCI USB 3 0 Hand off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled USB hardware delays and time outs USB transfer time out The time out val...

Страница 64: ...Controller Auto uses default value for a Root port it is 100 ms for a Hub port the delay is taken from Hub descriptor Options available Auto Manual Default setting is Auto Mass Storage Devices AMI Virtual CDROM_ Mass storage device emulation type AUTO enumerates devices according to their media format Optical drives are emulated as CDROM drives with no media will be emulated according to a drive t...

Страница 65: ...ions available Enabled Disabled Default setting is Disabled Ipv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Enabled Ipv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the PXE boot Press the keys to increase o...

Страница 66: ... 2 11 NVMe Configuration Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe LED Control Options available System Default Enabled Disabled Default setting is System Default ...

Страница 67: ... 67 BIOS Setup 5 2 12 SATA Configuration Parameter Description SATA Configuration Displays the installed HDD devices information System will automatically detect HDD type ...

Страница 68: ...tput Configuration Parameter Description Graphic Output Configuration Output Device Type Select output device Options available First loaded Device Onboard Device External Device Specific Device Default setting is Onboard Devicevice ...

Страница 69: ... 69 BIOS Setup 5 2 14 AMD Mem Configuration Status Parameter Description CPU0 1 Press Enter to view the memory configuration status related to CPU 0 1 ...

Страница 70: ...iguration of advanced items Enroll Cert Press Enter to enroll a certificate Enroll Cert Using File Cert GUID Input digit character in 1111111 2222 3333 4444 1234567890ab format Commit Changes and Exit Discard Changes and Exit Delete Cert Client Cert Configuration Press Enter for configuration of advanced items ...

Страница 71: ...Name Press Enter and name iSCSI Initiator Only IQN format is accecpted Range from 4 to 223 Add Attempt Press Enter for configuration of advanced items Delete Attempt Press Enter for configuration of advanced items Change Attempt Order Press Enter for configuration of advanced items ...

Страница 72: ...BIOS Setup 72 5 2 17 Intel R I350 Gigabit Network Connection ...

Страница 73: ...ort by blinking the associated LED Press the numeric keys to adjust desired values UEFI Driver Displays the technical specifications for the Network Interface Controller Adapter PBA Displays the technical specifications for the Network Interface Controller Device Name Displays the technical specifications for the Network Interface Controller Chip Type Displays the technical specifications for the ...

Страница 74: ...g VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 4094 Priority Sets 802 1Q Priority for a new VLAN or an existing VLAN Press the keys to increase or decrease the desired values The valid range is from 0 to 7 Add VLAN Press Enter to create a new VLAN or update an existing VLAN Configured VLAN List Remove VLAN Press Enter to remove an existing VLAN ...

Страница 75: ...Note Options available Enabled Disabled Default setting is Enabled Local IP Address Note Press Enter to configure local IP address Local NetMask Note Press Enter to configure local NetMask Local Gateway Note Press Enter to configure local Gateway Local DNS Servers Note Press Enter to configure local DNS servers Save Changes and Exit Press Enter to save all configurations Note This item appears whe...

Страница 76: ... for the device The string is colon separated e g ff dd 88 66 cc 1 2 3 DAD Transmit Count The number of consective Neighbor solicitation messages sent while performing Duplicate Address Detection on a tentative address A value of zero indicates that Duplicate Address Detection is not performed Policy Options available automatic manual Default setting is automatic Save Changes and Exit Press Enter ...

Страница 77: ...etup 5 3 AMD CBS Menu AMD CBS menu displays submenu options for configuring the CPU related information that the BIOS automatically sets Select a submenu item then press Enter to access the related submenu screen ...

Страница 78: ...BIOS Setup 78 5 3 1 CPU Common Options ...

Страница 79: ...ns available Auto Low Current Idle Typical Current Idle Default setting is Auto SEV ASID Count Specifies the maximum valid ASID which affects the maximum system physical address space Options available Auto 253 ASIDs 509 ASIDs Default setting is Auto SEV ES ASID Space Limit Control Space limit control for SEV ES ASIDs Options available Auto Manual Default setting is Auto Streaming Stores Control E...

Страница 80: ...efault is 1 cab be set to zero for analysis purpose as long as OS supports it Options available Enabled Disabled Default setting is Enabled Enhanced REP MOVSB STOSB Default is 1 cab be set to zero for analysis purpose as long as OS supports it Options available Enabled Disabled Default setting is Enabled REP MOV STOS Steaming Allows REP MOV STOS to use non caching streaming stores for large sizes ...

Страница 81: ...cept or decline enabling CCDs processor cores and threads When accepted you can control the number of CCDs to be used the number of cores to be used and whether to enable or disable Simultaneous Multithreading Technology SMT support SMT Control Can be used to disable symmetric multithreading To re enable SMT a POwer CYCLE is needed after select the Enable option Select Auto base on BIOS PCD PcdAmd...

Страница 82: ...le Disable Default setting is Auto L1 Region Prefetcher Use memory access history to fetch additional lines when the data access for a given instruction tends to be followed by other data accesses Options available Auto Enable Disable Default setting is Enable L2 Stream HW Prefetcher Enable Disable L2 Stream HW Prefetcher Options available Auto Enable Disabled Default setting is Enable L2 Up Down ...

Страница 83: ... 83 BIOS Setup 5 3 1 3 Core Watchdog Parameter Description Core Watchdog Core Watchdog Timer Enable Enable Disable CPU Watchdog Timer Options available Auto Enabled Disabled Default setting is Auto ...

Страница 84: ...Disable DF Sync Flood propagation Options available Auto Sync flood disabled Sync flood enabled Default setting is Auto Frezze DF module queues on error Options available Auto Enabled Disabled Default setting is Auto CC6 memory region encryption Controls whether or not the CC6 save restor memory is encrypted Options available Auto Enabled Disabled Default setting is Auto System probe filter Enable...

Страница 85: ...efault setting is Auto Poison scrubber control Enable Disable the Poison scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber control Enable Disable the Redirect scrubber control feature Options available Auto Enabled Disabled Default setting is Auto Redirect scrubber limit Sets the redirect scrubber limit Options available Auto 2 4 8 Infinite ...

Страница 86: ... remap Enable Disable to remap DRAM out of the space just below the 1TB boundary The ability to remap depends on DRAM configuration NPS and interleaving selection and may not always be possible Options available Auto Do not remap Attempt to remap Default setting is Auto DRAM map inversion Enable Disable the DRAM map inversion function Options available Auto Enabled Disabled Default setting is Auto...

Страница 87: ...Options available Auto Enabled Disabled Default setting is Auto ACPI SLIT Distance Control Determines how the SLIT distances are declared Options available Auto Manual Default setting is Auto ACPI SLIT remote relative distance Sets the remote socket distance for 2P systems as near 2 8 or far 3 2 Options available Auto Near Far Default setting is Auto ...

Страница 88: ... Options available Auto Enabled Disabled Default setting is Auto 4 link xGMI max speed Specifies the max speed of 4 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps 3 link xGMI max speed Specifies the max speed of 3 link xGMI Options available Auto 10 667Gbps 13Gbps 16Gbps 18Gbps Default setting is 10 667Gbps xGMI TXEQ Mode Configures xGMI TXEQ RX vett...

Страница 89: ... Common Options DDR4 Common Options Press Enter for configuration of advanced items DRAM Memory Mapping Press Enter for configuration of advanced items NVDIMM Press Enter for configuration of advanced items Memory MBIST Press Enter for configuration of advanced items ...

Страница 90: ...ng Memory speeds will be capped at AMD guidelines DRAM Controller Configuration Press Enter to configure DRAM Controller Configuration CAD Bus Configuration Press Enter to configure CAD Bus Configuration Data Bus Configuration Press Enter to configure Data Bus Configuration Common RAS Press Enter to configure Common RAS Security Press Enter to configure Security Phy Configuration Press Enter to co...

Страница 91: ... 91 BIOS Setup 5 3 3 1 1 Enforce POR ...

Страница 92: ...und UrgRefLimit DRAM Maximum Activate Count Options available Auto Unlimited MC 200K 300K 400K 500K 600K 700K Default setting is Auto DRAM Refresh Rate Options available 7 8 usec 3 9 usec Default setting is 7 8 usec Self Refresh Exit Staggering Options available Disabled Trfc 3 Trfc 4 Default setting is Disabled Cmd2T Selects the Cmd2T mode on ADDR CMD Options available Auto 1T 2T Default setting ...

Страница 93: ...iguration CAD Bus Timing User Controls Setup time on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto CAD Bus Drive Strength User Controls Drive Strength on CAD bus signals to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 94: ...3 1 4 Data Bus Configuration Parameter Description Data Bus Configuration Data Bus Configuration User Controls Specifies the mode for drive strength to Auto or Manual Options available Auto Manual Default setting is Auto ...

Страница 95: ...tion Options available Auto Enabled Disabled Default setting is Auto Max Parity Error Replay Configures the Max Parity Error Replay 0 0x3f Default setting is 8 Please note that this item is configurable when DRAM Address Command Parity Retry is set to Enabled Write CRC Enable Enable Disable the Write CRC function Options available Auto Enabled Disabled Default setting is Auto DRAM Write CRC Enable...

Страница 96: ...ems DRAM ECC Symbol Size Configures the DRAM ECC Symbol Size Options available Auto x4 x8 x16 Default setting is Auto DRAM ECC Enable Enable Disable DRAM ECC When set to Auto it will set ECC to enable Options available Auto Enabled Disabled Default setting is Auto DRAM UECC Retry Enable Disable DRAM UECC Retry Options available Auto Enabled Disabled Default setting is Auto ...

Страница 97: ...rameter Description Security TSME Enable Disable Transparent SME Options available Auto Enabled Disabled Default setting is Auto Data Scramble Enable Disable Data Scrambling Options available Auto Enabled Disabled Default setting is Auto ...

Страница 98: ...U Training Press Enter to configure PMU Training DFE Traing Enable Disable DDR power down mode Options available Auto Enabled Disabled Default setting is Auto FFE Write Training Auto Enabled Disabled Default setting is Auto PMU Pattern Bits Controls Auto Manual Default setting is Auto ...

Страница 99: ... No help string Options available Auto Enabled Disabled Default setting is Auto BankGroupSwapAlt Configures the BankGroupSwapAlt Options available Auto Enabled Disabled Default setting is Auto Address Hash Bank Enable Disable bank address hashing Options available Auto Enabled Disabled Default setting is Auto Address Hash CS Enable Disable CS address hashing Options available Auto Enabled Disabled...

Страница 100: ...BIOS Setup 100 5 3 3 3 NVDIMM Parameter Description NVDIMM Disable NVDIMM N feature for memory margin tool Options available No Yes Default setting is No ...

Страница 101: ...ce Mode Data Eye Mode Default setting is Auto MBIST Aggressors Note Enable Disable MBIST Aggressor test Options available Auto Enabled Disabled Default setting is Auto MBIST Per Bit Slave Die Reporting Note Enable Disable to report 2D data eye results in ABL log for each DQ Chipselect and Channel Options available Auto Enabled Disabled Default setting is Auto Data Eye Press Enter to configure adva...

Страница 102: ...ol function Options available Enabled Disabled Default setting is Disabled Aggressor Static Lane Select Upper 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select Lower 32 bits This item is configurable when Aggressor Static Lane Control is set to Enabled Aggressor Static Lane Select ECC This item is configurable when Aggressor Static ...

Страница 103: ... Voltage Sweep 1D Timing Sweep 2D Full Data Eye Worst Case Margin Only Default setting is Worst Case Margin Only Worst Case Margin Granularity Configures Worst Case Margin Granularity Options available Per Chip Select Per Nibble Default setting is Worst Case Margin Only Read Voltage Sweep Step Size Configures the step size for read Data Eye voltage sweep Options available 1 2 4 Default setting is ...

Страница 104: ...numeration ARI Forwarding Enable for each downstream port Options available Auto Enabled Disabled Default setting is Auto PCIe Ten Bit Tag Support Enable Disable PCIe ten bit tags for supported devices Auto Disabled Options available Auto Enabled Disabled Default setting is Auto SMU Common Options Press Enter for configuration of advanced items NBIO RAS Common Options Press Enter for configuration...

Страница 105: ...ilable Auto Manual Default setting is Auto Loopback Mode Enabled Disabled PCIe Loopback mode Options available Auto Enabled Disabled Default setting is Auto CV test Set this to Enabled to support running PCIECV tool Auto preserve hardware defaults Options available Auto Enabled Disabled Default setting is Auto CAC Weight Adjustment EDC Mode select Options available Auto Enabled Disabled Default se...

Страница 106: ...Control Selects use the fused TDP or set customized TDP TDP is used to define the RC thermal model only Options available Auto Manual Default setting is Auto cTDP Display cTDP information EfficiencyModeEn Options available Auto Enabled Default setting is Auto Package Power Limit Control Selects use the fused PPT or set customized PPT PPT will be used as the ASIC power limit Options available Auto ...

Страница 107: ...bled Disabled Default setting is Auto DLMM Support Select DLMM support enable or disable Options available Auto Enabled Disabled Default setting is Auto BoostFmaxEn Options available Auto Enabled Default setting is Auto EDC Current Options available Enable Disable Default setting is Disable LCLK Frequency Control Press Enter for advanced configuration DF PSTATE Mode Select Option available Normal ...

Страница 108: ...bit of 0 indicates LOW serverity NBIO SyncFlood Generation The value may be used to mask SyncFlood caused by NBIO RAS options Options available Auto Enabled Disabled Default setting is Auto NBIO SyncFlood Reporting The value may be used to enanle SyncFlood reporting to APML Options available Enabled Disabled Default setting is Disabled Egress Poison Mask High Enables mask for masking of errors log...

Страница 109: ... Default setting is Disabled SLINK Read Response Error Handling Options available Enabled Trigger MCOMMIT Error Log Errors in MCA Default setting is Log Errors in MCA Log Poison Data from SLINK Enable Disable the Log Poison Data from SLINK feature Options available Enabled Disabled Default setting is Disabled PCIe Aer Reporting Mechanism Selects the method of reporting AER errors from PCI Express ...

Страница 110: ...arameter Description FCH Common Options AC Power Loss Options Press Enter for configuration of advanced items FCH RAS Options Press Enter for configuration of advanced items Miscellaneous Options Press Enter for configuration of advanced items ...

Страница 111: ...S Setup 5 3 5 1 AC Power Loss Options Parameter Description AC Power Loss Options AC Loss Control Selects the AC Loss Control Method Options available Power Off Power On Last State Default setting is Power off ...

Страница 112: ...BIOS Setup 112 5 3 5 2 FCH RAS Options Parameter Description FCH RAS Options ALink RAS Support Enable Disable the ALink RAS Support Options available Auto Enabled Disabled Default setting is Auto ...

Страница 113: ... 113 BIOS Setup 5 3 5 3 Miscellaneous Options Parameter Description Miscellaneous Options Boot Time Enable Options available Auto Enabled Disabled Default setting is Auto ...

Страница 114: ...nable Disable the ConsoleOut function for ABL Options available Auto Enabled Disabled Default setting is Auto ABL PMU message Control Note To Control the total number of PMU debug messages Options available Auto Enabled Disabled Default setting is Auto Note This item appears when ABL Console Out Control is set to Enabled ...

Страница 115: ...eter Description Workload Tuning Workload Profile Select the profile for different workloads Default setting is Auto Performance Tracing Enable to allow capturing performance traces Options available Auto Enabled Disabled Default setting is Auto ...

Страница 116: ...king for protect ROM part Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn Reserved 1M bytes MMIO space on 1M boundary when iLA TraceMemoryEn disabled Options available Enabled Disabled Default setting is Disabled iLA TraceMemoryEn reserved MMIO Reserved function SRIS mode debug Control SRIS mode debug Options available Auto Enabled Disabled Default setting is Auto ...

Страница 117: ... Period GHES Notify Type Selects the Notification type for deferred corrected errors Options available Polled SCI Default setting is Polled GHES UnCorr Notify Type Selects the Notification type for uncorrected errors Options available Polled NMI Default setting is NMI PCIe GHES Notify Type Selects the Notification type for PCIe corrected errors Options available Polled SCI Default setting is Polle...

Страница 118: ...RR Notify Type Selects the Notification type for CCIX deffered error Options available Polled SCI Default setting is Polled CCIX GHES Corrected Err Notify Type Selects the Notification type for CCIX corrected error Options available Polled SCI Default setting is Polled DDR4 DRAM Hard Post Package Repair This feature allows spare DRAM rows to replace malfunctioning rows via an in field repair mecha...

Страница 119: ...ter to access the related submenu screen Parameter Description PCIe Compliance Mode Options available On Off Default setting is Off Program All VR Enable Disable program all VR on MB Options available Enabled Disabled Default setting is Enabled North Bridge Press Enter for configuration of advanced items Fabric Resource Press Enter for configuration of advanced items ...

Страница 120: ...er Description North Bridge Configuration Memory Information Total Memory Displays the total memory information CPU0 Information Press Enter to view information related to CPU 0 CPU1 Information Press Enter to view information related to CPU 1 ...

Страница 121: ... 121 BIOS Setup 5 5 2 Fabric Resource Parameter Description Fabric Resource Socket 0 1 NBIO_ PCIe Bus Number Change Socket 0 1 NBIO_ PCIe Bus Number ...

Страница 122: ... Default setting is Do Nothing OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configures OS Watchdog Timer Options available 5 minutes 10 minutes 15 minutes 20 minutes Default setting is 10 minutes Please note that this item is configurable when OS Watchdog Timer is set to Enabled OS Wtd Timer Policy C...

Страница 123: ...ed 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the FRU information BMC network configuration Press Enter to configure advanced items IPv6 BMC Network Configuration Press Enter to configure advanced items ...

Страница 124: ...e SEL Choose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Options availabl...

Страница 125: ...U Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 126: ...g is DynamicBmcDhcp Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information VLAN Support Set to BMC enabled diisabled VLAN Options available Enabled Disable...

Страница 127: ...twork during BIOS phase Options available Unspecified Disable Enable Default setting is Enable IPv6 BMC Lan IP Address Source Selects to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Enable Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the I...

Страница 128: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 129: ...ooting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its keys from the BIOS database Options avail...

Страница 130: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Страница 131: ...ber of seconds to wait for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Boot mode select Selects the boot ...

Страница 132: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 133: ...orities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 134: ...orities The UEFI application boot priorities submenu allows you to specify the boot device priority from the available UEFI applications during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 135: ...one so far to any of the setup options Options available Yes No Default Options Restore Defaults Loads the default settings for all BIOS setup parameters Setup Defaults are quite demanding in terms of resources consumption If you are using low speed memory chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options availab...

Страница 136: ...L was not found 3 DXE Core Firmware Volume was not found 4 Recovery failed 4 S3 Resume failed 7 Reset PPI is not available 5 10 2 DXE Beep Codes of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource r...

Страница 137: ... 137 BIOS Setup This page intentionally left blank ...