background image

System Hardware Installation

- 30 -

3-5  Installing the PCI Expansion Card

•  Voltages can be present within the server whenever an AC power source is connected. This 

voltage is present even when the main power switch is in the off position. Ensure that the 
system is powered-down and all power sources have been disconnected from the server prior to 
installing a PCI card.

Failure to observe these warnings could result in personal injury or damage to equipment.

•  The PCI riser assembly does not include a riser card or any cabling as standard. To install a PCI 

card, a riser card must be installed. 

Follow these instructions to PCI Expansion card:

1.  Remove the screws on the riser bracket

2.  Lift up the riser bracket out of system.
3.  Remove the slot covers from the riser bracket.
4.  Orient the PCIe card with the riser guide slot and push in the direction of the arrow until the PCIe 

card sits in the PCI card connector. 

5.  Secure the PCIe card with the screw.
6.  Reverse the steps 3 - 1 to install the riser bracket.

1

3

4

2

Содержание E162-220

Страница 1: ...E162 220 Edge Server 1U UP system with GPU supported User Manual Rev 1 0 ...

Страница 2: ... and BIOS User Guide detailed information about the installation use of an add on hardware or software component e g BMC firmware rail kit compatible with this product Quick Installation Guide a short guide with visual diagrams that you can reference easily for installation purposes of this product e g motherboard server barebones Please see the support section of the online product page to check ...

Страница 3: ...guide NOTE Gives bits and pieces of additional information related to the current topic CAUTION Gives precautionary measures to avoid possible hardware or software problems WARNING Alerts you to any damage that might result from doing or not doing specific actions ...

Страница 4: ...e risk of personal injury from hot surfaces allow the drives and the internal system components to cool before touching them WARNING This server is equipped with high speed fans Keep away from hazardous moving fan blades during servicing WARNING This equipment is not suitable for use in locations where children are likely to be present WARNING This equipment is intended to be used in Restrict Acce...

Страница 5: ...charge ESD and ESD protection ESD can damage drives boards and other parts We recommend that you perform all procedures in this chapter only at an ESD workstation If one is not available provide some ESD protection by wearing an antistatic wrist strap attached to chassis ground any unpainted metal surface on the server when handling parts ESD and handling boards Always handle boards carefully They...

Страница 6: ...on if battery is replaced incorrectly or with an incorrect type Replace the battery only with the same or equivalent type recommended by the manufacturer Dispose of used bat teries according to the manufacturer s instructions ...

Страница 7: ...stalling the CPU and Heat Sink 26 3 4 Installing the Memory 28 3 4 1 Eight Channel Memory Configuration 28 3 4 2 Installing a Memory 29 3 4 3 Memory Population Table 29 3 5 Installing the PCI Expansion Card 30 3 6 Installing the GPU Card 31 3 7 Installing the Hard Disk Drive 32 3 8 Installing the Mezannine Card 33 3 9 Installing and Removing an M 2 Solid State Drive 34 3 10 Replacing the Power Sup...

Страница 8: ...H Configuration 78 5 3 8 Miscellaneous Configuration 80 5 3 9 Server ME Configuration 81 5 3 10 Runtime Error Logging 82 5 3 11 Power Policy 84 5 4 Server Management Menu 86 5 4 1 System Event Log 88 5 4 2 View FRU Information 89 5 4 3 BMC VLAN Configuration 90 5 4 4 BMC Network Configuration 91 5 4 5 IPv6 BMC Network Configuration 92 5 5 Security Menu 93 5 5 1 Secure Boot 94 5 6 Boot Menu 96 5 6 ...

Страница 9: ... 9 5 8 9 Intel PM POST Codes 106 5 9 BIOS POST Beep code AMI standard 107 5 9 1 PEI Beep Codes 107 5 9 2 DXE Beep Codes 107 ...

Страница 10: ... 10 This page intentionally left blank ...

Страница 11: ...s dry and first touch a metal object to eliminate static electricity Prior to installing the motherboard please have it on top of an antistatic pad or within an electrostatic shielding container Before unplugging the power supply cable from the motherboard make sure the power supply has been turned off Before turning on the power make sure the power supply voltage has been set according to the loc...

Страница 12: ...z Socket ocket LAN 1 x 10 100 1000 management LAN Socket Socket Video Integrated in Aspeed AST2600 2D Video Graphic Adapter with PCIe bus interface 1920x1200 60Hz 32bpp DDR4 SDRAM Socket Socket Storage 2 x 2 5 SATA SAS Gen4 NVMe hot swappable HDD SSD bays SAS card is required for SAS devices support Socket Socket RAID Intel SATA RAID 0 1 10 5 Socket Socket Expansion Slot 1 x Full height Full lengt...

Страница 13: ...00W 80 PLUS Platinum hot swap power supply Socket ocket System Management Aspeed AST2600 management controller GIGABYTE Management Console AMI MegaRAC SP X web interface Dashboard JAVA Based Serial Over LAN HTML5 KVM Sensor Monitor Voltage RPM Temperature CPU Status etc Sensor Reading History Data FRU Information SEL Log in Linear Storage Circular Storage Policy Hardware Inventory Fan Profile Syst...

Страница 14: ...idity Operating temperature 10 C to 35 C Non operating temperature 40 C to 60 C Operating humidity 8 80 non condensing Non operating humidity 20 95 non condensing NOTE Ambient temperature limited to 30 C if using 280W CPU Socket Socket System Dimension 1U 438mm W x 43 5mm H x 500mm D ...

Страница 15: ... 15 Hardware Installation 1 3 System Block Diagram ...

Страница 16: ...Hardware Installation 16 This page intentionally left blank ...

Страница 17: ...ort x 2 5 10 100 1000 Server Management LAN Port 6 ID Button with LED 7 Mezzanine Card Slot Option OCP 3 8 PCIe Card Slot 9 PCIe Card Slot NOTE The Green HDD Latch Supports NVMe Please Go to Chapter 2 3 Front Panel LED and Buttons for detail description of function LEDs 2 2 Rear View 1 2 3 4 5 6 7 8 9 PSU1 PSU2 HDD0 HDD1 Fan1 Fan2 Fan3 Fan4 Fan5 Fan6 ...

Страница 18: ... power module failure Temperature and voltage issue Chassis intrusion N A Off System is not ready may indicate POST error Processor or terminator missing 2 Power button with LED Green On System is powered on Green Blink System is in ACPI S1 state sleep mode N A Off System is not powered on or in ACPI S5 state power off System is in ACPI S4 state hibernate mode 3 ID Button This LED represents the R...

Страница 19: ...1 1GbE Speed LED Yellow On 1Gbps data rate Green On 100 Mbps data rate N A Off 10 Mbps data rate 2 1GbE Link Activity LED Green On Link between system and network or no access Blink Data transmission or receiving is occurring N A Off No data transmission or receiving is occurring ...

Страница 20: ...Hz Green Blinking Power supply firmware updating mode Amber AC cord unplugged or AC power lost with a second power supply in parallel still with AC input power Power supply critical event causing shut down failure OCP OVP fan failure and UVP 1 Hz Amber Blinking Power supply warning events where the power supply continues to operate high temp high power high current and slow fan ...

Страница 21: ...Back Panel Removed HDD Slot LED on Back Panel Disk LED Removed HDD Slot RAID SKU No RAID configuration via HBA RAID configuration via HW RAID Card or SW RAID Card HDD Access HDD Present No Access BLINK 2 BLINK 2 OFF OFF OFF OFF OFF OFF Low Speed 2 Hz 3 3 Rebuilding HDD Fault OFF OFF ON OFF ON OFF OFF OFF Locate Amber Green ON 1 ON OFF ON 1 OFF Green Amber Green ON 1 Green OFF Amber Amber OFF LED1 ...

Страница 22: ...System Appearance 22 This page intentionally left blank ...

Страница 23: ...u are working inside the computer case If possible wear a grounded wrist strap when you are working inside the computer case Alternatively discharge any static electricity by touching the bare metal system of the computer case or the bare metal body of any other grounded appliance Hold electronic circuit boards by the edges only Do not touch the components on the board unless it is necessary to do...

Страница 24: ...ned on or connected to AC power Follow these instructions to remove the rear system cover 1 Push the plastic handle 2 Pull the grip handle to open the panel cover 3 Slide the cover to the front of the system and then remove the cover in the direction indicated by the arrow 4 To reinstall the chassis cover reverse steps 1 3 Push Li 1 2 3 ...

Страница 25: ...uct Follow these instructions to remove install the fan duct 1 Remove the two screws securing the fan duct 2 Lift up to remove the fan duct 3 To install the fan duct align the fan duct with the guiding groove Push down the fan duct into chassis until its firmly seats 1 2 ...

Страница 26: ...an Follow these instructions to install the CPU 1 Align the processor to the carrier so that the gold triangle on the processor aligns with the triangle on the carrier and then install the processor into the carrier NOTE Apply thermal compound evenly on the top of the CPU 2 Carefully flip the heatsink over Align the carrier assembly so that the triangle on the carrier aligns with the triangle on t...

Страница 27: ... 27 System Hardware Installation To install remove the Intel heatsink use a T30 Lobe screwdriver or drill bit with a screw torque of 8 0 0 5kgf cm 8lbf in 4 1 2 3 4 5 6 ...

Страница 28: ..._P0_C1 DIMM_P0_C0 DIMM_P0_D1 DIMM_P0_D0 DIMM_P0_A1 DIMM_P0_G1 DIMM_P0_G0 DIMM_P0_H1 DIMM_P0_F0 DIMM_P0_F1 DIMM_P0_E0 DIMM_P0_E1 DIMM_P0_H0 Read the following guidelines before you begin to install the memory Make sure that the motherboard supports the memory It is recommended that memory of the same capacity brand speed and chips be used Always turn off the computer and unplug the power cord from ...

Страница 29: ...Close the plastic clip at both edges of the DIMM slots to lock the DIMM module 3 Reverse the installation steps when you want to remove the DIMM module 1 2 2 3 4 3 Memory Population Table Type Ranks Per DIMM and Data Width DIMM Capacity GB Speed MT s Voltage V Slots per Channel SPC and DIMM per Channel DPC 1DPC 2DPC 8Gb 16Gb 1 2V 1 2V RDIMM SRx8 8GB 16GB 3200 3200 RDIMM SRx4 16GB 32GB RDIMM DRx8 1...

Страница 30: ...ld result in personal injury or damage to equipment The PCI riser assembly does not include a riser card or any cabling as standard To install a PCI card a riser card must be installed Follow these instructions to PCI Expansion card 1 Remove the screws on the riser bracket 2 Lift up the riser bracket out of system 3 Remove the slot covers from the riser bracket 4 Orient the PCIe card with the rise...

Страница 31: ... seated 4 Install the two screws to secure the GPU card in place 1 2 Before you install the GPU card l Voltages can be present within the server whenever an AC power source is connected This voltage is present even when the main power switch is in the off position Ensure that the system is powered down and all power sources have been disconnected from the server prior to installing a GPU card Make...

Страница 32: ... inserted incorrectly Make sure that the HDD is connected to the HDD connector on the backplane Follow these instructions to install a 2 5 hard disk drive 1 Press the release button 2 Extend the locking lever 3 Pull the locking lever to remove the HDD tray 4 Align the hard disk drive with the positioning stub on the HDD tray 5 Slide hard disk drive into the blank HDD tray 6 Reinsert the HDD tray i...

Страница 33: ...stall an OCP 3 0 mezzanine card 1 Remove the two screws securing the mezzanine card slot cover 2 Remove the slot cover from the system 3 Insert the OCP 3 0 mezzanine card into the card slot ensuring that the card is firmly connected to the connector on the motherboad 4 Tighten the thumbnail screw to secure the OCP 3 0 mezannine card in place 5 Reverse steps 3 4 to replace the OCP 3 0 mezzanine car...

Страница 34: ...4 to remove the M 2 device and the heatsink 1 3 2 4 WARNING Installation of the thermal pad over the M 2 device is required when installing an M 2 device Lack of the thermal pad may result in system overheat and throttle the system performance CAUTION The position of the stand off screw will depend on the size of the M 2 device The stand off screw is pre installed for 22110 cards as standard Refer...

Страница 35: ... the left side of the power supply unit along the direction of the arrow 2 Pull the power supply handle at the same time and pull out the power supply unit 3 Insert the replacement power supply unit firmly into the chassis Connect the AC power cord to the replacement power supply 4 Repeat steps 1 3 for replacement of the second power supply 2 3 1 ...

Страница 36: ... 36 System Hardware Installation HDD Back Plane Board Power Cable HDD Back Plane Board Signal Cable 3 11 Cable Routing BP_1 ...

Страница 37: ...System Hardware Installation 37 U 2 NMVe to HDD Back Plane Board Cable NMVe0 U 2 NMVe to HDD Back Plane Board Cable NMVe1 U2_2 U2_1 U2_1 U2_0 ...

Страница 38: ... 38 System Hardware Installation On Board SATA to HDD Back Plane Board Cable GPU Card Power Cable Recommend ...

Страница 39: ...tem Description 1 SlimLine SAS Connector U2_1 PCIe Gen4 2 SlimLine SAS Connector U2_2 PCIe Gen4 3 2 x 4 GPU Card Power Connector P12V_GPU 4 2 x 3 Front HDD Back Plane Board Connector 5 HDD Back Plane Board Connector 6 PCIe x16 Connector GENZ_3 Gen4 Signal 7 SlimLine SAS Connector SL_CN3 SATA Signal 8 VROC Upgrade Module Connector 9 OCP Mezzanine Connector OCP 3 0 SFF Gen4 x16 ...

Страница 40: ...ply Connector 2 Secondary 19 M 2 Connector PCIe Gen4 x 4 NGFF 22110 20 System Battery Cable Connector 21 SATA Connector SSATA5 22 SATA DOM Support Power Connector for SSATA5 23 M 2 Connector PCIe Gen4 x 4 NGFF 22110 24 M 2 Connector PCIe Gen4 x 4 NGFF 22110 25 System Fan Connector SYS_FAN1 26 System Fan Connector SYS_FAN2 27 System Fan Connector SYS_FAN3 28 System Fan Connector SYS_FAN4 29 System ...

Страница 41: ...rd Components 4 2 Jumper Settings CPU ME Force Update ME_UPDATE Enable Default 1 2 3 Password Clear BIOS_PWD Enable Default 1 2 3 BIOS Recovery BIOS_RCVR Default Enable 1 2 3 Enable Default 1 2 3 Clear CMOS CLR_CMOS ...

Страница 42: ...Motherboard Components 42 This page intentionally left blank ...

Страница 43: ... with caution Inadequate BIOS flashing may result in system malfunction It is recommended that you not alter the default settings unless you need to to prevent system instability or other unexpected results Inadequately altering the settings may result in system s failure to boot If this occurs try to clear the CMOS values and reset the board to default values Refer to the Exit section in this cha...

Страница 44: ... Change set or disable supervisor and user password Configuration supervisor password allows you to restrict access to the system and BIOS Setup A supervisor password allows you to make changes in BIOS Setup A user password only allows you to view the BIOS settings but not to make changes Boot This setup page provides items for configuration of the boot sequence Save Exit Save all the changes made...

Страница 45: ... displayed on the bottom line of the Main Menu Submenu Help While in a submenu press F1 to display a help screen General Help of function keys available for the menu Press Esc to exit the help screen Help for each item is in the Item Help block on the right side of the submenu When the system is not stable as usual select the Restore Defaults item to set your system to its defaults The BIOS Setup ...

Страница 46: ...U Signature Processor Core Microcode Patch Displays the technical specifications for the installed processor s Platform Information Processor PCH RC Revision Displays the platform information of the installed processor s and PCH Memory Information Total Memory Note1 Displays the total memory size of the installed memory Usable Memory Note1 Displays the usable memory size of the installed memory Me...

Страница 47: ... 47 BIOS Setup Parameter Description System Date Sets the date following the weekday month day year format System Time Sets the system time following the hour minute second format ...

Страница 48: ... Setup 48 5 2 Advanced Menu The Advanced Menu displays submenu options for configuring the function of various hardware components Select a submenu item then press Enter to access the related submenu screen ...

Страница 49: ...mputing Parameter Description Configuration Security Device Support Enable Disable the TPM support feature Options available Enable Disable Default setting is Enable Current Status Information Displays current TPM status information ...

Страница 50: ...tings Press Enter to configure advanced items Please note that this item is configurable when COM1 Console Redirection is set to Enabled Terminal Type Selects a terminal type to be used for console redirection Options available VT100 VT100 ANSI VT UTF8 Default setting is VT100 Bits per second Selects the transfer rate for console redirection Options available 9600 19200 38400 57600 115200 Default ...

Страница 51: ...lt setting is 1 Flow Control Flow control can prevent data loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Default setting is None VT UTF8 Comb...

Страница 52: ...nd Management Windows Emergency Management Services EMS Console Redirection Note EMS console redirection allows the user to configure Console Redirection Settings to support Out of Band Serial Port management Options available Enabled Disabled Default setting is Disabled Serial Port for Out of Band EMS Console Redirection Settings Press Enter to configure advanced items Please note that this item ...

Страница 53: ...ta loss from buffer overflow When sending data if the receiving buffers are full a stop signal can be sent to stop the data flow Once the buffers are empty a start signal can be sent to re start the flow Hardware flow control uses two wires to send start stop signals Options available None Hardware RTS CTS Software Xon Xoff Default setting is None ...

Страница 54: ... the serial port settings When set to Disabled displays no configuration for the serial port Options available Enabled Disabled Default setting is Enabled Current Displays the serial port base I O address and IRQ Possible Configures the serial port base I O address and IRQ Use Automatic Settings IO 3F8h IRQ 4 DMA IO 3F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 2F8h IRQ 3 4 5 7 9 10 11 12 DMA IO 3E8h IRQ 3 4...

Страница 55: ... expansion ROM for the related PCI E slot Options available Enabled Disabled Default setting is Enabled PCI Devices Common Settings Above 4G Decoding Enable Disable memory mapped I O to 4GB or greater address space Above 4G Decoding Options available Enabled Disabled Default setting is Enabled SR IOV Support If the system has SR IOV capable PCIe devices this item Enable Disable Single Root IO Virt...

Страница 56: ...nd off support Options available Enabled Disabled Default setting is Enabled USB Mass Storage Driver Support Note Enable Disable the USB Mass Storage Driver Support Options available Enabled Disabled Default setting is Enabled Port 60 64 Emulation Enables the I O port 60h 64h emulation support This should be enabled for the complete USB Keyboard Legacy support for non USB aware OS Options availabl...

Страница 57: ...ble Disable the Ipv4 HTTP feature Options available Enabled Disabled Default setting is Disabled IPv6 PXE Support Enable Disable the Ipv6 PXE feature Options available Enabled Disabled Default setting is Disabled IPv6 HTTP Support Enable Disable the Ipv6 HTTP feature Options available Enabled Disabled Default setting is Disabled PXE boot wait time Wait time in seconds to press ESC key to abort the...

Страница 58: ... Post Report Configuration Parameter Description Post Report Configuration Error Message Report Post Error Message Enable Disable the POST Error Message support Options available Enabled Disabled Default setting is Enabled ...

Страница 59: ...ation Parameter Description NVMe Configuration Displays the NVMe devices connected to the system NVMe OPROM Select Options available BIOS Build In NVMe Device Default setting is BIOS Build In NVMe Press Enter for advanced configuration ...

Страница 60: ... setting Skip Above 4G Decoding for VGA Enable Disable 64bit capable devices to be decoded in Skip Above 4G Address VGA Space Options available Enabled Disabled Default setting is Disabled P2P Bridge IO Size Setting PSP Bridge IO aligned to the size currently this mode only support UEFI Options available 0x100 0x150 0x1000 Default setting is 0x1000 PSP Performance for GPU Enable Disable PSP Perfor...

Страница 61: ... Setup 61 5 2 10 Tls Auth Configuration Parameter Description Save CA Configuration Press Enter for configuration of advanced items Client Cert Configuration Press Enter for configuration of advanced items ...

Страница 62: ...BIOS Setup 62 5 2 11 iSCSI Configuration Parameter Description Attempt Priority Press Enter for configuration of advanced items Host iSCSI Configuration Press Enter for configuration of advanced items ...

Страница 63: ... Setup 5 3 Chipset Setup Menu Chipset Setup menu displays submenu options for configuring the function of Platform Controller Hub PCH Select a submenu item then press Enter to access the related submenu screen ...

Страница 64: ...BIOS Setup 64 5 3 1 Processor Configuration ...

Страница 65: ... available Enable Disable Default setting is Enable Hardware Prefetcher Select whether to enable the speculative prefetch unit of the processor Options available Enable Disable Default setting is Disable L2 RF0 Prefetch Disable Options available Enable Disable Default setting is Disable Adjacent Cache Prefetch When enabled cache lines are fetched in pairs When disabled only the required cache line...

Страница 66: ... Mode Extensions Options available Enable Disable Default setting is Enable AES NI Enable Disable the AES NI Intel Advanced Encryption Standard New Instructions support function Options available Enable Disable Default setting is Enable Debug Coonsent ASD support Options available Enable Disable Default setting is Disable Total Memory Encryption Enable Disable Total Memory Encryption Options avail...

Страница 67: ...ault allocation Options available 1G 4G 16G 64G 256G 1024G Default setting is 1024G Isoc Mode Enable Disable the Isochronous support in order to meet the QoS requirements Quality of Service Options available Auto Enable Disable Default setting is Disable Numa Non Uniform Memory Access Enable Disable Non uniform Memory Access NUMA support to improve the system performance Options available Enable D...

Страница 68: ...uency Options available 9 6GB s 10 4GB s Auto Default setting is Auto SNC Sub NUMA Enable Disable Sub NUMA Cluster function Options available Disable Enable SNC2 2 clusters Default setting is Disable Stale AtoS Enable Disable Stale A to S directory optimization Options available Disable Enable Auto Default setting is Auto LLC dead line alloc Enable Disable fill dead lines in LLC Options available ...

Страница 69: ...lable POR Disable Default setting is Disable Memory Frequency Configures the maximum memory frequency Options available Auto 1200 1333 1400 1600 1800 1866 2000 2133 2200 2400 2600 2666 2800 2933 3000 3200 3400 OvrClk 3466 OvrClk 3600 OvrClk 3733 OvrClk 3800 OvrClk 4000 OvrClk 4200 OvrClk 4266 OvrClk 4400 OvrClk 4800 OvrClk Default setting is Auto Enable ADR Enables the detecting and enabling of AD...

Страница 70: ... NVDIMMs Erase ARM NVDIMMs Enable Disable Erasing and Arming NVDIMMs Options available Enable Disable Default setting is Enable Restore NVDIMMs Enable Disable Automatic restoring of NVDIMMs Options available Enable Disable Default setting is Enable Interleave NVDIMMs Controls if NVDIMMs are interleaved together or not Options available Enable Disable Default setting is Enable Assert ADR on Reset E...

Страница 71: ...ting is Disabled Correctable Error Threshold Correctable Error Threshold 1 32767 used for sparing tagging and leaky bucket Press the keys to increase or decrease the desired values Trigger SW Error Threshold Enable Disable Sparing trigger SW Error Match Threshold Options available Disabled Full Mirror Mode Partial Mirror Mode Default setting is Disabled Sparing SW Error Match Threshold Press the k...

Страница 72: ...er Description Memory RAS Configuration ADDDC Sparing Default setting is Disabled Column Correction Disable Default setting is Disable Set PMem Die Sparing Default setting is Enabled Patrol Scrub Default setting is Disabled ...

Страница 73: ... Tables Options available Enable Disable Default setting is Enable ACS Control Enable Programs ACS only to Chipset Pcie Root Ports Bridges Disable Programs ACS to all PCIe bridges Default setting is Enable DMA Control Opt In Flag Enable Disable DMA_CTRL_PATFORM_OPT_IN_FLAG AG in DRMA table in ACPI Not compatible with Direct Device Assignment DDA Default setting is Disable Interrupt Remapping Enabl...

Страница 74: ...on in Pre boot environment If DMAR table is installed in DXE and if VTD_INFO_PPI is installed in PEI Options available Enable Disable Default setting is Disable Intel VMD technology Press Enter to configure advanced items Intel VMD technology Note1 Intel VMD Configuration Enable Disable the Intel VMD support function Options available Enable Disable Default setting is Disable Note Advanced items p...

Страница 75: ... 75 BIOS Setup 5 3 6 Advanced Power Management Configuration Parameter Description Advanced Power Management Configuration ...

Страница 76: ... Options available Enable Disable Default setting is Disable Configure SST BF This option allows BIOS to configure SST BF High Priority Cores so that SW does not have to configure Options available Enable Disable Default setting is Enable Turbo Mode When this item is enabled the processor will automatically ramp up the clock speed of 1 2 of its processing cores to improve its performance When this...

Страница 77: ... When enabled the CPU core frequency and voltage will be reduced during system halt state to decrease power consumption The C6 state is a more enhanced power saving state than C1 Options available Disable Enable Auto Default setting is Auto Enhanced Halt State C1E Core C1E auto promotion control Takes effect after reboot Options available Enable Disable Default setting is Enable Package C State Co...

Страница 78: ...abled and cannot be access the RAID setup utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default setting...

Страница 79: ...setup utility at boot time RAID Mode When set to RAID the SATA controller enables both its RAID and AHCI functions You will be allowed to access the RAID setup utility at boot time Options available AHCI RAID Default setting is AHCI Alternate Device ID on RAID Note 1 Enable Disable Alternate Device ID on RAID mode Options available Enable Disable Default setting is Disabled sSATA Port 0 1 2 3 The ...

Страница 80: ... 8 Miscellaneous Configuration Parameter Description Miscellaneous Configuration Active Video Selects the active video type Options available Auto Onboard Device PCIE Device Specified PCIE Device Default setting is Auto ...

Страница 81: ...information Current State for ME Firmware Displays ME Firmware current status information Error Code for ME Firmware Displays ME Firmware status error code Recovery Cause for ME Firmware Displays ME Firmware recovery cause PTT Support Displays if the system supports the Intel Platform Trust Technology Suppress PTT Commands Displays if the system supports to Bypass TPM2 commands submitting to PTT F...

Страница 82: ...ure advanced items WHEA Windows Hardware Error Architecture Support Enable Disable WHEA Support Options available Enable Disable Default setting is Enable Memory Error Enabling Press Enter to configure advanced items Memory Error Enable Disable Memory Error Options available Enable Disable Default setting is Enable Memory Corrected Error Enable Disable Memory Corrected Error Options available Enab...

Страница 83: ...ble Errors to error pins Options available Enable Disable Default setting is Enable Fatal Error Enable Enables and escalates Fatal Errors to error pins Options available Enable Disable Default setting is Enable Assert NMI on SERR Enable Disable SERR propagation Options available Enable Disable Default setting is Enable Assert NMI on PERR Enable Disable PERR propagation Options available Enable Dis...

Страница 84: ...matically ramp up the clock speed of 1 2 of its processing cores to improve its performance When this item is disabled the processor will not overclock any of its core Options available Enabled Disabled Default setting is Enabled CPU C6 report Allows you to determine whether to let the CPU enter C6 mode in system halt state When enabled the CPU core frequency and voltage will be reduced during sys...

Страница 85: ...s Disabled Adjacent Cache Prefetch When enabled cache lines are fetched in pairs When disabled only the required cache line is fetched Options available Enabled Disabled Default setting is Enabled DCU Streamer Prefetcher Prefetches the next L1 data line based upon multiple loads in same cache line Options available Enabled Disabled Default setting is Enabled Isoc Mode Enable Disable the Isochronou...

Страница 86: ...s set to Enabled FRB 2 Timer Policy Configure the FRB2 Timer policy Options available Do Nothing Reset Power Down Power Cycle Default setting is Do Nothing Please note that this item is configurable when FRB 2 Timer is set to Enabled OS Watchdog Timer Enable Disable OS Watchdog Timer function Options available Enabled Disabled Default setting is Disabled OS Wtd Timer Timeout Configure OS Watchdog ...

Страница 87: ...d Wait BMC Ready POST wait BMC ready and reboot system Options available Disabled 2 minutes 4 minutes 6 minutes Default setting is 2 minutes System Event Log Press Enter to configure advanced items View FRU Information Press Enter to view the advanced items BMC VLAN Configuration Press Enter to configure advanced items BMC network configuration Press Enter to configure advanced items IPv6 BMC Netw...

Страница 88: ...ose options for erasing SEL Options available No Yes On next reset Yes On every reset Default setting is No When SEL is Full Choose options for reactions to a full SEL Options available Do Nothing Erase Immediately Delete Oldest Record Default setting is Do Nothing Custom EFI Logging Options Log EFI Status Codes Enable Disable the logging of EFI Status Codes if not already converted to legacy Opti...

Страница 89: ... Information The FRU page is a simple display page for basic system ID information as well as System product information Items on this window are non configurable Note The model name will vary depends on the product you purchased ...

Страница 90: ...ration BMC VLAN ID Select to configure BMC VLAN ID The valid range is from 0 to 4094 When set to 0 BMC VLAN ID will be disabled BMC VLAN Priority Select to configure BMC VLAN Priority The valid range is from 0 to 7 When BMC VLAN ID is set to 0 BMC VLAN Priority will not be selected ...

Страница 91: ...S phase Options available Unspecified Static DynamicBmcDhcp Default setting is Unspecified Station IP address Displays IP Address information Subnet mask Displays Subnet Mask information Please note that the IP address must be in three digitals for example 192 168 000 001 Router IP address Displays the Router IP Address information Station MAC address Displays the MAC Address information Real time...

Страница 92: ... network during BIOS phase Options available Unspecified Enable Disable Default setting is Enable IPv6 BMC Lan IP Address Source Select to configure LAN channel parameters statically or dynamically by BIOS or BMC Options available Unspecified Static Dynamic Obtained by BMC running DHCP Default setting is Dynamic Obtained by BMC running DHCP IPv6 BMC Lan IP Address Prefix Length Check if the IPv6 B...

Страница 93: ...ll settings in the Setup Utility User Password Entering this password will restrict a user s access to the Setup menus To enable or disable this field a Administrator Password must first be set A user can only access and modify the System Time System Date and Set User Password fields Parameter Description Administrator Password Press Enter to configure the administrator password User Password Pres...

Страница 94: ...plications that are running during the booting process to be pre signed with valid digital certificates This way the system knows all files being loaded before Windows loads to the login screen have not been tampered with When set to Standard it will automatically load the Secure Boot keys form the BIOS databases When set to Custom you can customize the Secure Boot settings and manually load its k...

Страница 95: ... Key Exchange Keys KEK Displays the current status of the Key Exchange Key Database KEK Press Enter to configure a new KEK or load additional KEK from storage devices Options available Set New Append Authorized Signatures DB Displays the current status of the Authorized Signature Database Press Enter to configure a new DB or load additional DB from storage devices Options available Set New Append ...

Страница 96: ... for setup activation key 65535 0xFFFF means indefinite waiting Press the numeric keys to input the desired values Bootup NumLock State Enable Disable the Bootup NumLock function Options available On Off Default setting is Off Quiet Boot Enable Disable showing the logo during POST Options available Enabled Disabled Default setting is Enabled Setup Flash Press Enter to run setup flash Boot mode sel...

Страница 97: ...ure the boot priority By default the server searches for boot devices in the following sequence 1 Hard drive 2 CD COM DVD drive 3 USB device 4 Network 5 UEFI UEFI Network Drive BBS Priorities Press Enter to configure the boot priority UEFI Application Boot Priorities Press Enter to configure the boot priority ...

Страница 98: ...rities The UEFI network drive BBS priorities submenu allows you to specify the boot device priority from the available UEFI network drives during system boot up BIOS setup will display an error message if the legacy drive s specified is not bootable ...

Страница 99: ...available Yes No Discard Changes and Exit Discards changes made and exits the BIOS setup Options available Yes No Save Changes and Reset Restarts the system after saving the changes made Options available Yes No Discard Changes and Reset Restarts the system without saving any changes Options available Yes No Save Changes Saves changes made in the BIOS setup Options available Yes No Discard Changes...

Страница 100: ...chips or other kinds of low performance components and you choose to load these settings the system might not function properly Options available Yes No Save as User Defaults Saves the changes made as the user default settings Options available Yes No Restore User Defaults Loads the user default settings for all BIOS setup parameters Options available Yes No Boot Override Press Enter to configure ...

Страница 101: ...PU_AP_INIT 0x34 PEI_CPU_BSP_SELECT 0x35 PEI_CPU_SMM_INIT 0x36 PEI_MEM_NB_INIT 0x37 PEI_MEM_SB_INIT 0x3B PEI_DXE_IPL_STARTED 0x4F DXE_CORE_STARTED 0x60 Recovery PEI_RECOVERY_AUTO 0xF0 PEI_RECOVERY_USER 0xF1 PEI_RECOVERY_STARTED 0xF2 PEI_RECOVERY_CAPSULE_FOUND 0xF3 PEI_RECOVERY_CAPSULE_LOADED 0xF4 S3 PEI_S3_STARTED 0xE0 PEI_S3_BOOT_SCRIPT 0xE1 PEI_S3_VIDEO_REPOST 0xE2 PEI_S3_OS_WAKE 0xE3 5 8 2 AMI S...

Страница 102: ...DXE_USB_RESET 0x9B DXE_USB_DETECT 0x9C DXE_USB_ENABLE 0x9D DXE_IDE_BEGIN 0xA0 DXE_IDE_RESET 0xA1 DXE_IDE_DETECT 0xA2 DXE_IDE_ENABLE 0xA3 DXE_SCSI_BEGIN 0xA4 DXE_SCSI_RESET 0xA5 DXE_SCSI_DETECT 0xA6 DXE_SCSI_ENABLE 0xA7 DXE_SETUP_VERIFYING_PASSWORD 0xA8 DXE_SETUP_START 0xA9 DXE_SETUP_INPUT_WAIT 0xAB DXE_READY_TO_BOOT 0xAD DXE_LEGACY_BOOT 0xAE DXE_EXIT_BOOT_SERVICES 0xAF RT_SET_VIRTUAL_ADDRESS_MAP_B...

Страница 103: ..._MICROCODE 0x59 PEI_CPU_INTERNAL_ERROR 0x5A PEI_CPU_ERROR 0x5A PEI_RESET_NOT_AVAILABLE 0x5B Recovery PEI_RECOVERY_PPI_NOT_FOUND 0xF8 PEI_RECOVERY_NO_CAPSULE 0xF9 PEI_RECOVERY_INVALID_CAPSULE 0xFA S3 Resume PEI_MEMORY_S3_RESUME_FAILED 0xE8 PEI_S3_RESUME_PPI_NOT_FOUND 0xE9 PEI_S3_BOOT_SCRIPT_ERROR 0xEA PEI_S3_OS_WAKE_ERROR 0xEB DXE_CPU_ERROR 0xD0 DXE_NB_ERROR 0xD1 DXE_SB_ERROR 0xD2 DXE_ARCH_PROTOCOL...

Страница 104: ...core settings 0xAA Transition links to full speed operation 0xAB Phy layer settings 0xAC Link layer settings 0xAD Coherency Settings 0xAE KTIRC is done 0xAF 5 8 4 Intel UPI POST Codes When system BSP tries to setup path for remote sockets or sends a Boot_Go command to remote socket in SetupSbspPathToAllSockets or SyncUpPbspForReset If the remote socket s hasn t checked in assert it is a fatal cond...

Страница 105: ...rain DDR 0xB7 Initialize CLTT OLTT 0xB8 Hardware memory test and init 0xB9 Execute memory init 0xBA Program memory map and interleaving 0xBB Program RAS configuration 0xBC Rank margin tool 0xBD MRC is done 0xBF 5 8 7 Intel MRC Error Codes No memory was detected 0xE8 Memory test failure 0xEB Different dimm types are detected installed in the system 0xED Number of HAs found in system greater than MA...

Страница 106: ...y Initialization 0xE0 Pre Link training 0xE1 Start of Gen3 EQ training 0xE2 Start of PState transition init 0xE3 Gen3 parameters override 0xE4 End of IIO Early Initialization 0xE5 Start of IIO Late initialization 0xE6 PCIE port initialization 0xE7 IOAPIC initialization 0xE8 VTD initialization 0xE9 IOAT initialization 0xEA DFX initialization 0xEB NTB initialization 0xEC Security Initialization 0xED...

Страница 107: ... Recovery failed 4 S3 Resume failed 7 Reset PPI is not available of Beeps Description 1 Invalid password 4 Some of the Architectural Protocols are not available 5 No Console Output Devices are found 5 No Console Input Devices are found 6 Flash update is failed 7 Reset protocol is not available 8 Platform PCI resource requirements cannot be met 5 9 BIOS POST Beep code AMI standard 5 9 1 PEI Beep Co...