The following functions can be displayed:

Resetting the oil volume counter

Resetting of the oil volume counter can be effected in the mode 

◊.

:

=> Hold down the key for at least 10 secs.

Press the key, after 5 secs. the displayed value will flash for 5 secs. Subsequently the (old) value remains
on the display again, now release the key and 

0

appears on the display.

Definition of the momentary consumption target value

Definition of the momentary consumption target value is effected in the mode/function momentary consump-
tion:

=> Hold down the key for at least 30 secs., but 32 secs. at the longest

Press the key, after 25 secs. the displayed momentary consumption will flash for 5 secs. As soon as the

flashing stops, release the key. As confirmation the service symbol and the momentary consumption as the
newly defined target value will flash for 5 secs.
Following a change in burner output (nozzle change, change in pump pressure etc.) the target value must be
redefined as specified above. The old target value is thereby overwritten.

Service function

If the oil flow is reduced by more than 10 % (e.g. in the event of a slowly blocking nozzle, preheater etc.), the
service symbol will appear on the display unit.

The prerequisite for this service function is previous input of the target value (see Definition of the momentary
consumption target value) with correct burner operation.

Deactivation of the service function

Procedure as for definition of the momentary consumption target value, however, hold down the key for longer
than 32 secs. This clears the target value and the service symbol:

=> Hold down the key for at least 32 secs.

Upon being released the service symbol flashes and the zero value on the display flashes for 5 secs. as
confirmation.

Function

Display

Momentary consump-
tion

Oil volume
(resettable)

◊ 

Oil volume
(total)

S

Total operating hours

Number of
burner startups

Reduced throughput
(see Service function)

Service

000000

l

0000.00

l

/

h

000000

l

0000.00

l

/

h

000000

h

Содержание GG35

Страница 1: ...Technical Information Installation Instructions Oil Issue February 2002 Right reserved to effect techn modifications in the interest of product improvement GB Brenner und Heizsysteme GG35 55 80 ...

Страница 2: ...hat the Giersch GG35 55 80 oil blow burner meets the basic requirements of the following direc tives Low Voltage Directives in compliance with 73 23 EEC in conjunction with DIN VDE 0700 part 1 issue 04 88 and DIN VDE 0722 issue 04 83 Electromagnetic Compatibility in compliance with directive 89 336 EEC in conjunction with EN 55014 issue 04 93 and EN 50082 1 issue 01 92 Machine Directives in compli...

Страница 3: ... diagram and taking into consi deration local regulations Protect the supply line with a 10 A fuse It is expedient to use a flexible cable When the plug unit is ready wired check the that the terminals comply with the wiring diagram below GG 35 V GG 35 GG 55 V GG 55 GG 80 Burner output in kg h in kW 1 00 3 35 12 40 1 20 3 35 14 40 1 00 5 05 12 60 1 20 5 05 14 60 3 35 6 75 40 80 Recommended boiler ...

Страница 4: ...nks are positioned higher the pump can be converted to a single line system For pure single line operation unscrew and remove the seal with the by pass plug which lies beneath it and screw the cap only back in Seal the return line opening by means of the gasket and metal plug For conversion to a single line system we recommend the use of a heating oil filter with return line feed In this way the p...

Страница 5: ...e from the ignition electrode Release the retarding disc and pull it up and off Release the oil nozzle open end wrench size 16 while holding the nozzle stock against turning with an open end wrench size 19 see illustration on left Replace the oil nozzle Reassemble in the reverse order When doing so on the GG55 take heed of the position of the measuring nipple small bore in the retarding disc Ident...

Страница 6: ...imension A Dimension A see Table of settings serves as an orienta tion aid for adjusting the burner Dimension A describes the position of the nozzle stock with the retarding disc in the cone of the burner tube Example Adjusting nut is turned clockwise The air throughput increases the CO2 content in the exhaust gas falls and the air pressure before the retarding disc drops By measuring the CO2 at t...

Страница 7: ...ignition If no flame has formed upon expiry of the safety period the de vice switches over to fault Following a mains power failure a restart takes place in any case In the presence of ex ternal light during the pre ventilation period the control device switches over to fault upon expiry of the safety period The control device may only be plugged in or unplugged if the main switch is in the OFF po...

Страница 8: ... This multifunction device provides information about the oil consumption the number of burner startups the burner operating hours etc and in addition gives a warning when the oil throughput drops below the set target value e g nozzle blocked Through early detection and elimination of the deficiency uneconomical and environmentally harmful operation of the burner can be prevented In operation ensu...

Страница 9: ...output nozzle change change in pump pressure etc the target value must be redefined as specified above The old target value is thereby overwritten Service function If the oil flow is reduced by more than 10 e g in the event of a slowly blocking nozzle preheater etc the service symbol will appear on the display unit The prerequisite for this service function is previous input of the target value se...

Страница 10: ... are reduced IMPORTANT When refurbishing existing plants over dimensioned smokestack cross sections or unsuitable smokestacks are very often specified for NT operation etc We recommend that you make an appraisal of the smokestack system together with the responsible local chimney sweep prior to installing the boiler plant so that suitable refurbishing measures can be defined at an early stage for ...

Страница 11: ...11 G 04 02 02 19 Circuit diagram GG35 55 80 with TF830 832 Burner Boiler control GG35 55 V with TF830 832 Boiler control Burner ...

Страница 12: ...12 G 04 02 02 GG35 55 80 with LOA 24 Boiler control Burner GG35 55 V with LOA 24 Boiler control Burner ...

Страница 13: ...ocked Clean replace plug in correctly Replace Check ignition electrode and adjustment ignition transformer and cable Open Top up oil Clean Seal Replace Seal Replace nozzle Replace Clean filter and replace solenoid valve see Operability check of the control device Replace Replace Flame extinguishes during operation Oil supply consumed Nozzle filter blocked Oil filter or oil feed lines soiled Air in...

Страница 14: ...2 17 5 16 0 1 5 0 45 60 10 19 20 10 15 2 0 2 2 20 0 18 5 1 7 0 50 60 10 20 21 16 19 2 0 2 2 24 0 22 0 2 0 0 55 60 10 22 23 22 25 2 1 2 3 27 0 24 5 2 3 0 60 60 10 23 24 25 28 2 2 2 4 30 0 27 5 2 5 0 65 60 10 25 26 29 32 2 2 2 4 33 0 30 5 2 8 0 75 60 10 26 27 33 37 2 3 2 5 39 0 36 0 3 3 0 85 45 60 10 27 28 39 43 2 3 2 6 41 0 37 5 3 5 1 00 45 60 10 28 30 46 50 2 3 2 6 47 5 43 5 4 0 1 10 45 60 10 29 3...

Страница 15: ...64 13 Burner hood 1 47 10 21765 14 Fan wheel dia 133x42 GG35 55 1 31 10 11477 14 Fan wheel dia 133x52 GG80 1 47 10 21729 15 Admission nozzle GG35 1 47 20 22528 15 Admission nozzle 1 47 20 21774 47 30 21774 16 Danfoss BFP 21LG pump with connection parts 1 31 10 10187 17 Oil hose length 1200 mm 1 47 10 10802 18 Ignition transformer cpl as spare 1 47 10 11260 19 Control device bottom part Satronic 1 ...

Страница 16: ...sions 24 Working ranges Boiler connection dimensions M8 min 88 150 All dimensions in mm Dimensions in brackets are valid for GG80 2 0 1 6 1 2 0 8 0 4 0 Throughput kg h GG55 10 2 0 3 0 4 0 5 0 6 0 Burner capacity kW 1 2 3 4 5 F u r n a c e r e s i s t a n c e m b a r 2 0 1 6 1 2 0 8 0 4 0 Throughput kg h GG55 V Burner capacity kW 1 2 3 4 5 F u r n a c e r e s i s t a n c e m b a r 10 2 0 3 0 4 0 5 ...

Отзывы: