background image

 

Manual

 

according to regulation DIN 82079

 

Version 10.19 

Date: 14.10.2019 

Name: Manual_VARIO-MA

 

 

GIEBEL FilTec GmbH • We

www.giebel-adsorber.de

 

 Email 

[email protected]

 

 Tel +49 (0) 7946 944401-0 

 

3/9 

Section 5: 

Assembly and commissioning 

 

Proceed as follows to install the entire adsorber:  

1.  Switch off the system. 
2.  Screw the valve part onto the plant. Lightly oil the thread first. 
3.  Place the O-ring in the groove provided in the valve section and 

check that it is seated correctly. 

4.  Remove the safety plug from the valve part. 
5.  Peel off the protective foil on the underside of the adsorber part. 
6.  Push the adsorber part onto the sleeve of the valve part. 
7.  Hook the tensioning bracket into the closing hooks and push the 

tensioning levers downwards. 

8.  Secure the clamp with the safety plugs

 

 

Section 6: 

maintenance 

 

Procedure for reusable adsorbers 

1.  Switch off the system.  
2.  Remove the adsorber part by opening the closing clamps. 
3.  Open the cover and remove it from the adsorber part. 
4.  Remove the seal in the cover and replace it with a new one. 
5.  Remove the activated charcoal disc and empty the desiccant.  
6.  Pull out the dust filter insert. 
7.  Remove the lower foam disk as well. 
8.  Insert new foam disk. 
9.  Insert a new dust filter insert and then 

Fill with fresh desiccant. When filling the  
Using a soft object (e.g. ball of the hand), lightly knock the desiccant 
against the housing to compact the filling. 

10. Insert a new activated carbon disc and then close the lid again. 
11. Replace O-rings between valve part and adsorber part. 
12. If necessary, clean the lower foam disk with compressed air. 
13. Place the adsorber section back on the valve section and remove the  

Close the clamps. 

 

Procedure for disposable adsorbers 

1.  Switch off the system.  
2.  Remove the adsorber part by opening the  

Closure clamps. 

3.  New O-ring between valve section and adsorber section  

in. 

4.  Place the new adsorber part on the valve part and  

Close the clamps. 

 

 

 

Содержание DV 310-MA

Страница 1: ...lTec GmbH Carl Zeiss Str 5DE 74626 Bretzfeld Schwabbach Phone 49 0 7946 944401 0 Fax 49 0 7946 944401 29 E mail info giebel adsorber de Section 2 Adsorber overview DV 300 MA DV 320 MA DV 310 MA DV 330 MA DV 510 MA DV 530 MA DV 560 MA DV 790 MA Materials used Aluminium acrylonitrile butadiene rubber NBR activated carbon moulded carbon Silica gel amorphous silicon dioxide REACH notice No ingredients...

Страница 2: ...perature 40 C 80 C Mounting part MA receiving part DV 3 MA DV 5 MA connection customs housing material Aluminium seal material NBR FKM Section 4 Technical Data VARIO MA D DV 300 MA DV 320 MA Total weight kg 3 0 3 8 Adsorbent kg 0 9 1 3 Height mm 300 400 Housing diameter mm 110 110 Insertion diameter mm 150 150 connection G 1 STS SW36 G 1 STS SW36 Valves IN OUT 1 1 1 1 VARIO MA R DV 310 MA DV 330 M...

Страница 3: ...the system 2 Remove the adsorber part by opening the closing clamps 3 Open the cover and remove it from the adsorber part 4 Remove the seal in the cover and replace it with a new one 5 Remove the activated charcoal disc and empty the desiccant 6 Pull out the dust filter insert 7 Remove the lower foam disk as well 8 Insert new foam disk 9 Insert a new dust filter insert and then Fill with fresh des...

Страница 4: ...gel Orange Green 4kg Order of spare parts For constant operational readiness of the adsorber and thus of the hydraulic unit or transmission make sure that there is always a spare parts package or a spare adsorber part in stock The time to complete saturation of the activated carbon by the adsorption of oil mist and thus also the service life of the adsorber depends on various factors Number and du...

Страница 5: ...elevant legal regulations Metal and plastic parts should be separated according to type and disposed of The loaded drying agent Silicagel Orange can be disposed of in household waste Silicagel Orange is not classified as a hazardous substance according to European Union legislation Regulation EC No 1272 2008 According to the EC Directive 67 548 EEC or 1999 45 EC it is not subject to labelling Sili...

Страница 6: ...irt particles Prefilter disc contaminated The filter unit can be clogged by dirt particles Oil film on the desiccant Oil particles collect in the pores of the silica gel Dirt particles can accumulate on the oil film and thus hinder the supply or exhaust air 2 Humid air flows into the system Porous seals Moist air can flow into the adsorber at the porous points This means that complete drying is no...

Страница 7: ...the ambient temperature exceeds 80 C the incoming ambient air is only dried to a limited extent Adsorber housing is damaged Material resistance When selecting an adsorber the ambient and operating conditions should be taken into account Vibrations of the system Strong vibrations of the system can damage the adsorber 4 Thread from adsorber and accessories is damaged When installing the adsorber and...

Страница 8: ...2 Check filter unit for impurities Check Remove the lid from the adsorber part and remove the activated charcoal disc Then empty the desiccant The filter unit can then be removed This must be checked for impurities and should be free of dirt for smooth operation Cycle Half yearly Action The filter unit is part of the spare parts package and should be replaced if there is contamination 3 Check pref...

Страница 9: ... Action If the valves do not open and close replace the valve part with a new one to ensure full functionality 6 Optical control of the adsorber Check The adsorber valve part and adsorber part must be visually checked for damage Damage can occur due to various environmental or operating conditions Cycle Weekly Action If the adsorber is damaged replace the damaged part to ensure full functionality ...

Отзывы: