Section 5:
Assembly and commissioning
Proceed as follows to install the entire adsorber:
1. Switch off the system.
2. Screw the valve part onto the plant. Lightly oil the thread first.
3. Place the O-ring in the groove provided in the valve section and
check that it is seated correctly.
4. Remove the safety plug from the valve part.
5. Peel off the protective foil on the underside of the adsorber part.
6. Push the adsorber part onto the sleeve of the valve part.
7. Hook the tensioning bracket into the closing hooks and push the
tensioning levers downwards.
8. Secure the clamp with the safety plugs
.
Section 6:
maintenance
Procedure for reusable adsorbers
1. Switch off the system.
2. Remove the adsorber part by opening the closing clamps.
3. Open the cover and remove it from the adsorber part.
4. Remove the seal in the cover and replace it with a new one.
5. Remove the activated charcoal disc and empty the desiccant.
6. Pull out the dust filter insert.
7. Remove the lower foam disk as well.
8. Insert new foam disk.
9. Insert a new dust filter insert and then
Fill with fresh desiccant. When filling the
Using a soft object (e.g. ball of the hand), lightly knock the desiccant
against the housing to compact the filling.
10. Insert a new activated carbon disc and then close the lid again.
11. Replace O-rings between valve part and adsorber part.
12. If necessary, clean the lower foam disk with compressed air.
13. Place the adsorber section back on the valve section and remove the
Close the clamps.
Procedure for disposable adsorbers
1. Switch off the system.
2. Remove the adsorber part by opening the
Closure clamps.
3. New O-ring between valve section and adsorber section
in.
4. Place the new adsorber part on the valve part and
Close the clamps.