Troubleshooting Guide
Problem
Possible cause
Solution
The threshold control does not
work
The thresholds have not been set
Set the threshold values by follow-
ing the relevant instructions
The instrument checks the thresh-
olds incorrectly
Parameters for the threshold con-
trol have not been set
Make sure that they are set accord-
ing to the desired modes
The semi-automatic zero-function
does not work
The gross weight exceeds the ac-
tion limit of semiautomatic zero
To restore zero the weight must be
calibrated
The weight does not stabilize
Wait for the weight to stabilize or
adjust the weight filter parameter
The autotara function does not
work
The gross weight is negative or has
reached the maximum capacity
Check the gross weight
The weight does not stabilize
Wait for the weight to stabilize or
adjust the weight filter parameter
Serial communication does not
work properly
The connection was not correctly
executed
Check the connection as described
in the installation manual
Baud rate and data format have not
been set correctly
Check the settings in the serial
menu