Pump Specifications - P202-4120, P202-4121 and P202-4127
U.S.
Metric
Volume............................................................... 1.27 GPM* .........................4.8 L/min*
Discharge Pressure ...........................................
3190 PSI
............................220 Bar
Crankshaft Speed ..........................................................................................1450 RPM
Plunger Diameter............................................... 0.47” ...................................12mm
Plunger Stroke ...................................................
0.39”
...................................10mm
Crankshaft Diameter.......................................... 0.98” ...................................24mm
Key Width ..........................................................
0.31”
...................................8mm
Crankshaft Mounting .....................................................................................Either side
Crankshaft Rotation .........................................................Top of Pulley Towards Fluid End
Temperature of Pumped Fluids ......................... 140
o
F .................................60
o
C
Inlet Ports ......................................................................................................(2) 1/2”
BSP
Discharge Ports .............................................................................................(2) 1/4” BSP
Weight ...............................................................
13.9 lbs.
.............................10 kg
Crankcase Oil Capacity ..................................... 9.5 Ounces. ........................0.28 Liters
* Theoretical displacement per revolution is approximately 0.115 ounce (3.39 cm
3
)
Important!
The 1/8” rinsing connection on both sides serves to place a separating agent (e.g.
DOP) behind the medium seal on the suction side. This stops leakage (e.g. with Iscocyanate)
from crystallizing. When pumping different types of Freon, the pressure in the rinsing system
should be approximately 7.25 PSI (0.5 bar) higher than on the suction side of the pumped me-
dium.
To vent the pump easily on the discharge side, it is recommeded to install a T-piece with a high-
pressure cut-off tap as close as possible to the discharge port.
HORSEPOWER RATINGS:
The rating shown are the power
requirements for the pump. Gas engine
power outputs must be approximately
twice the pump power requirements
shown above.
We recommend a 1.15 service factor be
specified when selecting an electric motor as
the power source. To compute specific pump
horse power requirements, use the following
formula:
HP = (GPM X PSI) / 1450
Horsepower Requirements
P202-4120, P202-4121 and P202-4127
RPM
GPM
500 PSI 1000 PSI 2000 PSI 3190 PSI
725
0.64
0.22
0.44
0.88
1.4
900
0.79
0.27
0.55
1.09
1.7
1200
1.05
0.36
0.72
1.5
2.3
1450
1.27
0.44
0.88
1.8
2.8