29-LX ALIGNMENT 

REVISION: 00 

ENG-29-LX-08 

 

2.0 

Ali

 gnment of P.L.L. portion of CB and WX. 

2.1 

Equipment required: 

A: Oscilloscope 
B: DC voltage meter . 

2.2 

Alignment procedure: 

TEST ITEM 

TEST CONDITION & PROCEDURE 

PURPOSE 

1.

 

CB TX VCO voltage 

@ CH40 

1.

 

CB  TP3  OUTPUT  

  @ TX mode 

2.

 

WX VCO voltage 

@ CH8 / CH10 

Connect the DC volt. Meter to the 

junction point of R59 and R60. 

Connect  the  oscilloscope  to  the  junction  
  point of R6 and JP14. 

Connect the DC volt. Meter to the TP601 

Adjust 

L19

 to obtain approximately 

3.0V 

0.2V reading. 

Adjust 

L20

  for  maximum  output  on  

  the oscilloscope. 
1.

 

Adjust  L605  to  obtain  approx  1.5 

0.1V  

  @CH8 (162.650MHz) 
2.

 

Checking the CH10 the volt 

≤ 

 3.0V  

3.0 

Alignment of CB receiver portion. 

3.1 

Equipment required: 
A: Signal generator  
B: AC voltmeter.  
C: Oscilloscope.  
D: Dummy load ( 8 ohm, 5 watts, resistive.) E: 
DC power supply ( 13.8 v. 2Amp.)  

3.2 

Alignment procedure: 

TEST ITEM 

1. AUDIO OUTPUT 
 
 
 
 
 
 

2. RX Sensitivity 
 
 
 
 

3. NB 
 
 
 

4.Tight Squelch 
 
 

5.  “S-9”  and  +30  meter  
  indicator. 
 

6.  PA  output  RF  Level  
  @1mV, 30% Mod. 

TEST CONDITION & PROCEDURE 

1.

 

Set channel 19. 

2.

 

Set  the  S.G.  on  27.185MHz  with  1KHz,  

 

30% mod. and 1mV output level. 

3.

 

Set NB/OFF SW to OFF, Squelch to min.  

  ( CCW), CB/WX/PA to CB, ANL SW to  
  CB/ANL, RF GAIN to max. Volume  
  approximately Center. 
1.

 

Same as above step 1 and 3. 

2.

 

Set  the  S.G. on 27.185MHz  with 1KHz,  

  30% mod. RF output level 1.0uV. 

 
 

1.

 

Set NB/OFF SW to NB. 

2.

 

Set the level of S.G. to 1.0uV. 

3.

 

Noise generator to on. 

4.

 

Adjusted then revert item 1 setup.  

1.

 

Set Squelch volume to maximum ( CW ). 

2.

 

Set the level of S.G. to 1500uV.  

3.

 

Adjusted then revert item 1 setup.  

1.

 

Set the level of S.G. to 100uV.  

2.

 

Set the level of S.G. to 3.16mV. 

 

1. Set CB/WX/PA to PA function 

PURPOSE 

1.

 

Adjust 

L1,2,3,4,5,6

7

 for 

maximum  audio  output  &  minimum 
distortion on the distortion meter. 

 
 
 

1.

 

Adjust 

L1,2,3,4,5,6

&

7

 for more  

  than 12dB to the SINAD meter.  
2.

 

Repeat as needed. 

3.

 

Set RF S.G. output level 0.4uV, the adj.  

 

VR2

 to 2V on the AC volt meter.  

1.

 

Turn the volume to obtain 2V reading  

  on AC voltmeter. 

2.  Adjust 

L1

  for  minimum  reading  on  AC  

  volt meter. 

1.

 

Slowly turn 

VR4

 to a position that the  

  audio output waveform at the scope  
  just appears from no output. 

1.

 

Adjust 

VR1

  for  “S-9”  reading  on  

  The LCD meter. 

2. Check the bars up to +30. 

1.  Checking  the  audio  output  need  more  
  than 3.5W @10%THD  

 
 
 
 
 
 

Page: 4 / 6 