background image

c. Insert the jumper into 2-3 

3. Clear all PINs: 

     a. Reset Master Code to default value (5 beeps, clearing all PINs) 

b. Insert the jumper into 2-3 

 

 
 

 

  Enter Setting Mode 

Enter the master code twice (Default value: “1234” or “12345) to enter setting mode (2 beeps) 

  Note:  1. After 60 seconds if no data entered, it will automatically exit the setting mode.  

2. The controller will be locked for 60 seconds upon 30 consecutive master codes 

attempt.  

 
 

  Add new PINs  (In setting mode) 

1. Enter Master code twice (2 beeps) 
2. Slot position 

01~

21 

3. Enter the PINs (1 beep)  
4. Repeat, or press “#” to exit setting mode 

 
Relay 1 is controlled by the slot position 

01~

20 

Relay 2 is controlled by the slot position 

21 

Note: “00000”, “1234”, “12345” and master code cannot be used for PINs.  

 
 

 

Set the Relay Strike Time (In setting mode)

 

1. Enter the master code twice (2 beeps) 
2. Press 

30 (or 

31)  

3. Press 05 (01~99) (1 beep)  

Press 05 will set the relay strike to 5 seconds, relay set to toggle mode by press “00” 

4. Press “#” to exit setting mode 
Note: In Toggle mode, the relay will switch between N.C. contact and N.O. contact by input 

PIN once. 

 
 

  Delete PINs (In setting mode) 

1. Enter the master code twice (2 beeps) 
2. Press 

06 (e.g. code to delete) 

3. Press 0000 (or 00000) (1 beep)  
4. Press “#” to exit setting mode  

 
 

  Change Master Code (In setting mode) 

1. Enter the master code twice (2 beeps) 
2. Press

00  

3. Enter new master code (1 beep)  

4. Press “#” to exit setting mode  
 
 
 
 
 
 
 
 
 
 
 
 

Copyright All Rights Reserved. 