background image

Copyright © All Rights Reserved.   P-MU-ML-300  Ver. H  Publish: 2010.12.24

4 - 1

ML-300 
ML-300-SW

Operating Voltage» ML-300: 12 or 24VDC

                               ML-300-SW: 12~24VDC/AC

Voltage Tolerance» ±10%

Current Draw» ML-300: 280mA/12VDC; 140mA/24VDC

                       ML-300-SW: 210mA/12VDC; 150mA/24VDC

Version Changeable» Fail-safe or Fail-secure  

Operating Temperature» -10~45°C

Humidity» 0~95% non-condensing

Lock bolt sensor switch output» SPDT rated 3A/125VAC

Solenoid testing» Tested to 1,000,000

!

cycles

Net Weight» ML-300: 800g / ML-300-SW: 815g

Just applicable to vertical installation

Copyright © All Rights Reserved.   P-MU-ML-300  Ver. H  Publish: 2010.12.24

4 - 4

62mm cylinder  for max 

42mm  door leaf

72mm cylinder  for max 

52mm  door leaf

ø5.0

ø5.0

25

28

150

28

124

250

30

30

5

6

7

8

30

ø5.0

ø5.0

1

2

3

4

Electromechanical Lock
Installation Instruction

Specification

Double Swing Doors

Double swing door

Outswing

Inswing

Version Changeable:

Take out the Screw 1 , release screw 2 , move the 
position and then tighten both screws.

“Fail-Safe” 

(Power to Lock)

“Fail-Secure” 

(Power to Open)

Caution:

Fixing Lug

Allen wrench (1.6mm)

NIB

Lock bolt

Strike Plate

For double swing door For single swing door

Euro profile 

key cylinder

Unit:mm

Installation Instructions

Do

or le

af

Doo

r Fr

ame

Door Loop
(Optional)

(Cy

lind

er n

ot inc

lud

ed

)

Align the center line (CL) of the 

Alignment CL

Fra

me

Do

or 

Le

af

Do

or 

Le

af

Cut out mortise holes for the lock 

Tighten the fixing lugs with 

screws.

Drill and cut the hole for the lock 

Connect power cable to the lock 

Attach the cover plates for the

 Install the cylinder

Fix the strike plate.

Stud bolt Position

Packing Contents

Do not completely remove screw 2 (as marked in the figure) 
as the interior solenoid might fall off.

The door loop protects the wiring 
from damage at the door hinge.

Attention! Please ensure that the 
direction of the template is correct

Do

or F

ram

e

lock body template with the CL of 
the door leaf. Ensure the CL of the 
strike plate template matches the lock 
body CL as closely as possible.

body and strike plate and drill holes 
according to the templates.

cylinders as shown in the template.

and test before screwing to the 
door leaf.

cylinder lock 

For fail-safe mode

For fail-secure mode