Giacomini GE556-1 Series Скачать руководство пользователя страница 14

6

0865EN  

August 2018

M

etering

 

systeMs

H

eat

 I

nterface

 U

nIt

 

w

doUble

 

Heat

 

excHanger

 

In

 

parallel

 

confIgUratIon

ge556Y176 - 177 (ge556-1 

serIes

)

047U57408

Large heat exchanger for domestic water production  (GE556Y177)

Primary circuit

1,00

0,10

0,01

0,1

1,0

10,0

Q [m

3

/h]

Δ

p [bar]

0,66

Kv =

0,74 0,84

0,87

0,86

R206B-1 opening % 

20%

40%

60%

80%

100%

Kv

0,66

0,76

0,84

0,86

0,87

Primary circuit for heating, dynamic balancing valve fully open and regulation on 
static balancing valve R206B-1 

Primary circuit for domestic hot water production, dynamic balancing valve fully open

1,00

0,10

0,01

0,1

1,0

10,0

Q [m

3

/h]

Δ

p [bar]

Kv = 1,5

Heating

Heating

Radiators

Flowrate [l/h] and primary outlet 

temperature (radiators 65-53 °C)

Circulator 

speed

Flowrate 

[m

3

/h]

Power

[kW]

80 °C

75 °C

72 °C

Max

1,2

17,4

670

(57 °C)

950

(59 °C)

1350

(61 °C)

Primary circuit data for radiator heating.

Heating

Radiant floor

Flowrate [l/h] and primary outlet

temperature (radiators 45-38 °C)

Circulator 

speed

Flowrate 

[m

3

/h]

Power

[kW]

70 °C

65 °C

60 °C

Max

1,2

10,0

280

(39 °C)

340

(39 °C)

430

(40 °C)

Primary circuit data for floor radiant heating.

Circulator for heating

0

0

200

400

600

800

1000

1200

1

2

3

4

5

6

7

∆p [m H

2

O]

Q [l/h]

Domestic hot water production

Table 10 – Primary circuit data for domestic hot water production.

DHW

Flowrate [l/h] and primary outlet

temperature (DHW 10-50 °C)

l/min

l/h

kW

80 °C

75 °C

70 °C

65 °C

60 °C

12

720

33

450

(15,4 °C)

495

(16,9 °C)

565

(18,7 °C)

660

(21,3 °C)

825

(24,9 °C)

15

900

42

575

(16,8 °C)

640

(18,3 °C)

730

(20,4 °C)

870

(23,3 °C)

1105

(27,2 °C)

17

1020

47

660

(17,7 °C)

740

(19,4 °C)

850

(21,6 °C)

1010

(24,4°C)

1300

(28,5 °C)

20

1200

56

790

(18,9 °C)

890

(20,7 °C)

1030

(23,1 °C)

1260

(26,3 °C)

24

1430

67

970

(20,6 °C)

1100

(22,6 °C)

1280

(25,1 °C)

0,1

0,01

0,10

1,00

1,15

4,5

1,0

10,0

Q [m

3

/h]

Δ

p [bar]

Kv

Description

Ref. “Components” image

1,15

Domestic hot water

A-E

4,5

Domestic cold water

A-B

Hydraulic data for hot and cold domestic water circuits.

Содержание GE556-1 Series

Страница 1: ...ith VDI 2035 ÖNORM 5195 Description GE556Y171 is an Heat Interface Unit HIU for heating production it is fed by means of hot water from centralised boiler plant e g district heating Versions and product codes Product code Type Heat exchanger nominal power kW Jig with valves Heating SHW GE556Y171 Heating 17 4 GE551Y081 GE551Y083 Main features Painted RAL9010 steel cabinet for external installation ...

Страница 2: ...ents On each HIUs it is possible to install the following optional components Thermal energy meter GE552 series The flow temperature sensor of energy meter has to be installed into the appropriate housing Components Ref 5 Insulation in expanded PEx product code GE551Y180 Template with valves and 3 4 connections code GE551Y081 Template with valves filters and Ø 22 mm connections codeGE551Y083 GE551...

Страница 3: ...C The primary circuit is composed of an air vent valve a dynamic balancing valve a 2 way zone valve motorised a brass spacer an housing for installing thetemperatureprobeoftheenergymeter aby passvalveandathermostatic head to control the temperature In place of the brass spacer Components Ref 4 a thermal energy meter can be mounted by installing the temperature probe in the appropriate housing Comp...

Страница 4: ...ad Components Ref 8 Position 1 2 3 4 5 Temperature C 23 34 45 56 67 Warning Provide a safety thermostat for the low temperature heating applications If you notice that the rating temperature of the heating is higher than the set value the flow of the primary may be too high and the thermostatic head is not able to close To balance the heating production functions you can adjust the dynamic balanci...

Страница 5: ...200 1 2 3 4 5 6 7 p m H 2 O Q l h Circulator features Operations Automatic constant pressure difference recommended Automatic variable pressure difference Automatic air vent routine 10 min duration the pump runs alternatively with high and low speeds to help air bubbles to collect and to go to the air vent in the installation LED errors green continuous Normal running green flashing Automatic oper...

Страница 6: ...ions 450 450 65 92 55 57 49 157 180 630 180 C D F G X Y Legend C Primary outlet D Primary inlet F Heating delivery G Heating return X Hole for safety valve drain Y Hole for electrical cables Dimensions in mm Normative references UNI EN 1434 EN 60751 EN 61107 Measuring Instruments Directive 2004 22 CE MID ErP Directive 2004 22 CE ...

Страница 7: ...7 0548EN August 2018 Metering systems Heat Interface Unit w heat exchanger for heating GE556Y171 GE556 1 series 047U53338 ...

Страница 8: ... equivalent appliance the distributor is obliged to collect the product for disposal free of charge The product is not potentially dangerous for human health and the environment but if abandoned in the environment can have negative impact on the environment Read carefully the instructions before using the product for the first time It is recommended that you do not use the product for any purpose ...

Страница 9: ...y are fed by means of hot water from centralised boiler plant e g district heating The present version uses a configuration of two heat exchangers in parallel this has two principal advantages Parallel and non intermittent handling of the domestic hot water and heating functions Higher safety the heating circuit is a sealed pressurised system should there be any leaks within property only a small ...

Страница 10: ...ONTROLS A Domestic cold water inlet B Domestic cold water outlet C Primary outlet D Primary intlet E Domestic hot water outlet F Heating delivery G Heating return Optional components On each satellites it is possible to install the following optional components Thermal energy meter GE552 series The flow temperature sensor of energy meter has to be installed into the appropriate housing Components ...

Страница 11: ...310 1120 4 3 0 316 1140 4 4 0 322 1160 4 5 0 328 1180 4 6 0 334 1200 4 7 0 340 1220 4 8 0 346 1240 4 9 0 352 1270 5 0 DHW cold water inlet A cold water outlet B hot water outlet E The domestic water circuit is composed of a heat exchanger a brass spacer a flow switch a thermostatic mixing valve and a check valve In place of the brass spacer Components Ref 14 a domestic cold water meter can be inst...

Страница 12: ...e fit the locking nut to the stem to prevent unauthorised adjustment of the valve and replace the cap on the valve body Heating Adjust the heating temperature using the thermostatic head Components Ref 8 Position 1 2 3 4 5 Temperature C 23 34 45 56 67 Warning Provide a safety thermostat for the low temperature heating applications If you notice that the rating temperature of the heating is higher ...

Страница 13: ...350 61 C Primary circuit data for radiator heating Heating Radiant floor Flowrate l h and primary outlet temperature radiators 45 38 C Circulator speed Flowrate m3 h Power kW 70 C 65 C 60 C Max 1 2 10 0 280 39 C 340 39 C 430 40 C Primary circuit data for floor radiant heating Circulator for heating 0 0 200 400 600 800 1000 1200 1 2 3 4 5 6 7 p m H 2 O Q l h DHW production DHW Flowrate l h and prim...

Страница 14: ...ator heating Heating Radiant floor Flowrate l h and primary outlet temperature radiators 45 38 C Circulator speed Flowrate m3 h Power kW 70 C 65 C 60 C Max 1 2 10 0 280 39 C 340 39 C 430 40 C Primary circuit data for floor radiant heating Circulator for heating 0 0 200 400 600 800 1000 1200 1 2 3 4 5 6 7 p m H 2 O Q l h Domestic hot water production Table 10 Primary circuit data for domestic hot w...

Страница 15: ...Automatic constant pressure difference recommended Automatic variable pressure difference Automatic air vent routine 10 min duration the pump runs alternatively with high and low speeds to help air bubbles to collect and to go to the air vent in the installation LED errors green continuous Normal running green flashing Automatic operation for air elimination green red flashing Abnormal situation p...

Страница 16: ...urchase of an equivalent appliance the distributor is obliged to collect the product for disposal free of charge The product is not potentially dangerous for human health and the environment but if abandoned in the environment can have negative impact on the environment Read carefully the instructions before using the product for the first time It is recommended that you do not use the product for...

Отзывы: