Wired Remote Controller 

GIA

-

XK19

16

Table 4 Meaning of Each Error

Error

Error
Code

Error

Error
Code

Return air temperature sensor open/short 
circuited

F1

Drive board communication error

P6

evaporator temperature sensor open/short 
circuited

F2

Compressor overheating protection

H3

Indoor unit liquid valve temperature sensor 
open/short circuited

b5

Indoor and outdoor units unmatched

LP

Indoor gas valve temperature sensor open/
short circuited

b7

Communication line misconnected or
expansion valve error

dn

IPM temperature sensor open/short circuited

P7

5XQQLQJPRGHFRQÀLFW

E7

Outdoor ambient temperature sensor open/
short circuited

F3

Pump-down

Fo

Outdoor unit condenser mid-tube temperature 
sensor open/short circuited

F4

Defrost or oil return 

Discharge temperature sensor open/short 
circuited

F5

Forced defrosting

H1

Indoor and outdoor communication error

E6

Compressor startup failure

Lc

DC bus under-voltage protection

PL

High discharge temperature protection

E4

DC bus over-voltage protection

PH

Overload protection

E8

Compressor phase current sensing circuit 
error

U1

Whole unit over-current protection

E5

Compressor demagnetization protection

HE

Over phase current protection

P5

PFC protection

Hc

Compressor desynchronizing

H7

IPM Temperature Protection

P8

IPM Current protection

H5

Over-power protection

L9

C o m p r e s s o r   p h a s e   l o s s / r e v e r s a l
protection

Ld

S y s t e m   c h a r g e   s h o r t a g e   o r   b l o c k a g e 
protection

F0

Frequency restricted/reduced with whole
unit current protection

F8

Capacitor charging error

PU

Frequency restricted/reduced with IPM
current protection

En

High pressure protection

E1

Frequency restricted/reduced with high
discharge temperature

F9

Low pressure protection

E3

Frequency restricted/reduced with anti-
freezing protection

FH

Compressor stalling

LE

Frequency restricted/reduced with
overload protection

F6

Over-speeding

LF

Frequency restricted/reduced with IPM
temperature protection

EU

Drive board temperature sensor error

PF

Indoor unit full water error

E9

AC contactor protection

P9

Anti-freezing protection

E2

Temperature drift protection

PE

AC input voltage abnormal

PP

Sensor connection protection

Pd

Whole unit current sensing circuit error

U5

DC bus voltage drop error

U3

4-way valve reversing error

U7

Outdoor fan 1 error protection

L3

Motor stalling

H6

Outdoor fan 2 error protection

LA

PG motor zero-crossing protection

U8

Содержание GIATSU GIA-XK19

Страница 1: ...OWNER S MANUAL WIRED CONTROLLER REMOTE CONTROL ENGLSIH Thanks for choossing our product Please read carefully this manual before using the product GIA XK19 GIA YT1F...

Страница 2: ...ctly under the sunlight Never beat throw and frequently disassemble the wired remote controller and the wireless remote controller Never operate the wired remote controller and the wireless remote con...

Страница 3: ...4 Fan Setting 4 3 5 Timer Setting 5 3 6 Swing Setting 6 3 7 Sleep Setting 7 3 8 Turbo Setting 8 3 9 E heater Setting 9 3 10 Blow Setting 10 3 11 Other Functions 11 4 Installation and Dismantlement 11...

Страница 4: ...Mode Function Timer On Off SHIELD MEMORY MASTER SAVE BLOW QUIET CO2 AUTO TURBO SET HOUR F E HEATER A U T O Fig 1 Outside View of the Wired Remote Controller 1 2 LCD of the Wired Remote Controller SHIE...

Страница 5: ...ginal setting state after power failure and then power recovery 11 Master wired remote controller this function is yet unavailable for this unit 12 It blinks under on state of the unit without operati...

Страница 6: ...ress Repress them for 5s to quit this state 4 6 0RGH Under OFF state the Celsius and Fahrenheit scales can be switched by SUHVVLQJ 0RGH DQG IRU YH VHFRQGV 5 7 Function Timer Under OFF state it is avai...

Страница 7: ...5 On State 3 2 Mode Setting Under the On state of the unit press Mode to switch the operation modes as the following sequence Auto Cooling Dry Fan Heating Auto Cooling Dry Fan Heating 3 3 Temperature...

Страница 8: ...Fig 7 3 5 Timer Setting Under the On Off state of the unit press Timer to set timer off on Timer on setting press Timer and then LCD will display xx x hour with hour blinking In this FDVH SUHVV RU WR...

Страница 9: ...ig 8 Timer off Setting under the On State of the Unit 7LPHU UDQJH KU YHU SUHVV RI RU ZLOO PDNH WKH VHW WLPH LQFUHDVHG RU GHFUHDVHG E 0 5hr If either of them is pressed continuously the set time will i...

Страница 10: ...ng Off When the Swing function is on press Function to enter the Swing setting interface with blinking After that press Enter Cancel to cancel this function Swing setting is shown as Fig 9 Fig 9 Swing...

Страница 11: ...p setting interface After that press Enter Cancel to can this function In the Cooling or Dry mode the temperature will increase by 1 after the unit runs under Sleep 1 for 1hr and 1 after another 1hr A...

Страница 12: ...approach the setting value In the Cooling or Heating mode press Function till the unit enters the Turbo setting interface DQG WKHQ SUHVV QWHU DQFHO WR FRQ UP WKH VHWWLQJ When the Turbo function is act...

Страница 13: ...ote controller enters the Heating mode this function will be turned on automatically Press Function in the Heating mode to enter the E heater setting interface and then press Enter Cancel to cancel th...

Страница 14: ...the Blow function is activated press Function to the Blow setting interface and then press Enter Cancel to cancel this function Blow function setting is as shown in Fig 13 Fig 13 Blow Setting Notes Wh...

Страница 15: ...r ambient temperature is the sensed at the wired controller 02 in the timer display area Select the temperature sensor at the return air inlet under the cooling dry and fan modes while select the temp...

Страница 16: ...r to the 4 pin socket of the indoor unit PCB Tighten the signal wire with ties The communication distance between the main board and the wired remote controller can be up to 20 meters the standard dis...

Страница 17: ...nd the soleplate of the wired remote controller 3 Stick the soleplate of the wired remote controller to the wall over the installation hole and WKHQ LW ZLWK VFUHZV 0 4 Insert the four core twisted pai...

Страница 18: ...n lines of the wired remote controller must be the shielding twisted pair lines 4 3 Dismantlement of the Wired Remote Controller 1 3 4 2 5 Errors Display If there is an error occurring during the oper...

Страница 19: ...ole unit over current protection E5 Compressor demagnetization protection HE Over phase current protection P5 PFC protection Hc Compressor desynchronizing H7 IPM Temperature Protection P8 IPM Current...

Страница 20: ...which is not available for the corresponding function the unit will keep the original running status 1 Function of Press Buttons Fig 17 1 ON OFF Press this button to turn on off the unit After that t...

Страница 21: ...imer value 6 LIGHT Light On and Light Off can be set by pressing this button when the unit is at On or Off status After powered on the default is Light On 7 TURBO In Cool or Heat mode pressing this bu...

Страница 22: ...me increased or decreased by 1 minute If the button is pressed down for more than 2 seconds the time will be changed quickly in VXFK D ZD UVWO WKH YDOXH RQ WKH RQH V SODFH LV FKDQJHG DQG WKHQ LV WKH Y...

Страница 23: ...nit the whole unit will be stopped completely b About AFTERHEAT X FAN Under the Heat mode or Auto Heat mode if the unit is turned off the compressor and outdoor fan will stop running immediately and t...

Страница 24: ...C Industria 13 l Pol gono Industrial El Pedregar 08160 Montmel Barcelona Spain Phone 0034 93 390 42 20 Fax 0034 93 390 42 05 info giatsu com www giatsu com...

Отзывы: