background image

LIMITED WARRANTY:

This limited warranty is extended to the original retail purchaser of this Forced Air/Convection/Radiant Heater and warrants against any

defect in materials and workmanship for a period of one (1) year from the date of retail sale. GHP Group, Inc., at it’s option, will either 

provide replacement parts or replace or repair the unit, when properly returned to the retailer where purchased or one of our service centers

as directed by GHP Group, Inc., within one (1) year of retail purchase. (Shipping costs, labour costs, etc. are the responsibility of the purchaser.)

DUTIES OF THE OWNER:

This heating appliance must be operated in accordance with the written instructions furnished with this heater. This warranty shall not excuse

the owner from properly maintaining this heater in accordance with the written instructions furnished with this heater. A bill of sale, canceled

check or payment record must be kept to verify purchase date and establish warranty period. Original carton should be kept in case of warranty

return of unit.
WHAT IS NOT COVERED:

1.

Damage resulting from use of improper fuel.

2.

Damage caused by misuse or use contrary to the owners manual and safety guidelines.

3.

Damage caused by a lack of normal maintenance.

4.

Fuses

5.

Use of non-standard parts or accessories.

6.

Damage caused in transit. Freight charges on warranty parts or heaters to and from the factory shall be the responsibility of the owner.

This warranty does not imply or assume any responsibility for consequential damages that may result from the use, misuse, or the lack of

routine maintenance of this heating appliance. A cleaning fee and the cost of parts may be charged for appliance failures resulting from lack of
maintenance. This warranty does not cover claims which do not involve defective workmanship or materials. FAILURE TO PERFORM
GENERAL MAINTENANCE (INCLUDING CLEANING) WILL VOID THIS WARRANTY.

THIS LIMITED WARRANTY IS GIVEN TO THE PURCHASER IN LIEU OF ALL OTHER WARRANTIES, EXPRESSED OR IMPLIED,

INCLUDING BUT NOT LIMITED TO THE WARRANTIES OF MERCHANTABILITY OF FITNESS FOR A PARTICULAR PURPOSE. THE

REMEDY PROVIDED IN THIS WARRANTY IS EXCLUSIVE AND IS GRANTED IN LIEU OF ALL OTHER REMEDIES. IN NO EVENT WILL

GHP GROUP, INC. BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES. 

Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not

allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you.

CLAIMS HANDLED AS FOLLOWS:

1. Contact your retailer and explain the problem.

2. If the retailer is unable to resolve the problem, contact ourCustomer Service Dept. detailing the heater model, the problem, and proof

of date of purchase.

3. A representative will contact you. DO NOT RETURN THE HEATER TO GHP GROUP,INC. unless instructed by our Representative.

This warranty gives you specific legal rights and you may also have other rights which vary from state to state.

TO REGISTER THE WARRANTY ON YOUR HEATER, PLEASE FILL OUT THIS CARD COMPLETELY

AND MAIL WITHIN 14 DAYS FROM DATE OF PURCHASE OR REGISTER ON-LINE AT www.ghpgroupinc.com

NAME: ______________________________________ PHONE: (

) __________________ EMAIL: ____________________________

ADDRESS: _________________________________ CITY: ______________________________ STATE: __________ ZIP: ____________

MODEL: ____________________ SERIAL #: _______________________________________ DATE PURCHASED: __________________

DEALER PURCHASED FROM: ____________________________________________ TYPE OF STORE: __________________________

CITY & STATE WHERE PURCHASED: ______________________________________________ PRICE PAID: _______________________

Please Take a Minute To Give Us Your Answers To The Following Questions.

All Responses Are Used Solely For Market Research And Are Held In Strict Confidence.

Who primarily decided this purchase?

Male

Female

18-24

25-39

40-59

60 and over

Purpose of Purchase? _______________________________________________________________________________________________

Do you own any other portable heaters? Yes No If yes, type____________________________brand_____________________

How do you intend to use your new heater?

Construction Site

Farm

Warehouse/Commercial

Garage/Outbuilding Other

How did you become aware of this heater?

In-Store Display

Newspaper Ad

Magazine Ad

Friend/Relative

TV Commercial

Store Salesperson Other ___________________________

What made you select this heater?

Style

Size/Portability

Price

Package

Brand

Other ___________________

Do you:

own

rent Would you recommend this heater to a friend?

Yes

No

Please give us your comments:________________________________________________________________________________________

THANK YOU FOR COMPLETING THIS FORM!

Information will be held confidential.

WARRANTY

18

Содержание TT15CDGP

Страница 1: ...sion burn asphyxiation carbon monoxide poisoning and or electrical shock Only persons who can understand and follow the instructions should use or service this heater If you need assistance or heater information such as an instruction manual labels etcetera contact the manufacturer CONSUMER Retain this manual for future reference ANS Z83 7b 2009 CSA 2 14b 2009 50 10 153 Printed in China Rev 2012 0...

Страница 2: ......

Страница 3: ...E THE HEATER IN SPACES WHICH DO OR MAY CONTAIN VOLATILE OR AIRBORNE COMBUSTIBLES OR PRODUCTS SUCH AS GASOLINE SOLVENTS PAINT THINNERS DUST PARTICLES OR UNKNOWN CHEMICALS GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 Web www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 w...

Страница 4: ...lure to provide adequate ventilation could result in poisoning or death Other standards govern the use of fuel gases and heat producing products in specific applications Your local authority can advise you about these IMPORTANT Read this user s manual carefully and completely before trying to operate or service this heater Improper use of this heater can cause serious injury or death from fire exp...

Страница 5: ... heater is for use with propane gas only do not convert heater to any other gas Installation must conform to local codes or in the absence with the standard for the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and the Natural Gas and Propane Installation Code CSA B149 1 The minimum and maximum inlet pressures to the regulator from the gas tank are 17 5 psi and bottle pressure res...

Страница 6: ...ws supplied into the bolt holes attaching tank collar bracket to center plate on manifold Fig 1 Tools Required Phillips head screwdriver FIGURE 1 Tip Over Switch Manifold Tank Collar Bracket Electrode Machine Screw Heat Regulator Knob Handwheel Piezo NOTE some models only Electrode Cable Mounting Bolt Knob Dual Burner Model 5 PROPANE TANK TOP HEATER Estimated Assembly Time 5 minutes Contents Tank ...

Страница 7: ...Wiring Diagram 6 PROPANE TANK TOP HEATER ELECTRODE THERMOCOUPLE TIP OVER SWITCH M P U SAFETY VALVE PIEZO IGNITER Piezo models only earth yellow yellow black ...

Страница 8: ...ever store a Propane gas tank inside a building or in the vicinity of any gas burning appliance THE DISCONNECTED TANK MUST NEVER BE STORED IN A BUILDING GARAGE OR ANY OTHER ENCLOSED AREA ALL NEW CYLINDERS MUST BE PURGED BEFORE THE FIRST FILLING Turn heater gas valve knob and gas tank valve to OFF position Propane tank valve equipped with the old style fitting has LEFT HANDED THREADS Turn POL fitti...

Страница 9: ...Figure 3 NOTE Heater features a hand wheel that can be used to tighten the fitting to the cylinder No wrench required NOTE The vertical stem of this heater must be installed in the vertical position This heater is equipped with a safety shutoff switch in the event that the heater is tipped over during operation The heater may fail to remain lit if the vertical stem is not installed vertically 5 Fo...

Страница 10: ... Propane Tank Valve Piezo NOTE some models only Fuel Connecting Bolt Handle Mounting Bolt knob Inlet Connector Connecting Heater to Propane Tank Tip over Switch Electrode Mounting Bolt Knob Propane Tank Valve Inlet Connector Handwheel Heat Regulator Knob Wing Bolt Safety Shut off valve Piezo NOTE some models only Heat Regluator Knob Electrode After setting support leg tighten wing nut 9 PROPANE TA...

Страница 11: ... heater If it is evident that there is excessive abrasion or wear or the hose is cut it must be replaced prior to the heater being put into operation The replacement hose assembly shall be that specified by the manufacturer Checking for Leaks WARNING Never use an open flame to check for leaks Operation Lighting Instructions When Using Match Read and understand all safety information before operati...

Страница 12: ...ht second burner FIGURE 4 Lighting Instructions When Using Match Continued 1 Open Cylinder valve by turning counterclockwise 2 Turn heater regulator knob clockwise to the High position Fig 4 WARNING Stand to the side of unit while lighting Do not stand or have any part of your body over or in front of heater while lighting CAUTION Do not insert match into air inlet holes in mixing tube 4 Push in t...

Страница 13: ... square foot opening for fresh air supply for 15 000 BTU s of heat and one square foot opening for 30 000 BTU s of heat Operation Lighting Instructions for Piezo Ignition Models Read and understand all safety information before operating heater WARNING Burner and Burner Guard should always face away from propane tank shut off and regulator WARNING Improper installation alteration service or mainte...

Страница 14: ...e plunger 8 If burner goes out repeat steps 5 through 7 or use a match If heater will not light after repeated attempts do not attempt to repair heater 9 When burner is lit turn heater regulator knob to desired heat setting LOW MED or HIGH 10 On dual burner models light both burners when maximum heat is needed Use one burner to conserve fuel Lighting Instructions for Piezo Ignition Models Continue...

Страница 15: ...propane tank after each use and store indoors Do not store heater while attached to propane tank Do not store propane cylinders in a building garage or any other enclosed area The tank must be disconnected and stored outdoors in a well ventilated area out of reach of children in accordance with the standard for the the Storage and Handling of Liquefied Petroleum Gases ANSI NFPA 58 and CSA B149 1 N...

Страница 16: ...models only 2 Ignitor misaligned with Thermocouple shield 2 Realign ignitor with thermocouple shield 3 Wire frayed or damaged 3 Replace wire 5 Flames flashback burn inside 1 Debris or spider webs in mixing tube 1 Clean burner tube with bottle brush rinse in water the mixing tube and drain thoroughly before reintsalling 2 Clogged orifice 2 Remove and clean using compressed air PROBLEM POSSIBLE CAUS...

Страница 17: ...REPLACEMENT PARTS ILLUSTRATION 16 PROPANE TANK TOP HEATER TT30 SERIES TT15 SERIES Replacement Parts Illustration 16 PROPANE TANK TOP HEATER TT30 Series TT15 Series ...

Страница 18: ...THIS PAGE INTENTIONALLY LEFT BLANK 17 ...

Страница 19: ...w long an implied warranty lasts so the above limitation may not apply to you Some states do not allow the exclusion or limitation of incidental or consequential damages so the above limitation or exclusion may not apply to you CLAIMS HANDLED AS FOLLOWS 1 Contact your retailer and explain the problem 2 If the retailer is unable to resolve the problem contact ourCustomer Service Dept detailing the ...

Страница 20: ...e entire serial number Retain this portion of the card for your records SAVE THIS CARD Place Postage Stamp Here GHP Group Inc 8280 Austin Avenue Morton Grove IL 60053 3207 GHP Group Inc 8280 Austin Ave Morton Grove IL 60053 3207 Tel 877 447 4768 www ghpgroupinc com 8280 Austin Avenue Morton Grove IL 6 0 0 5 3 3 2 0 7 Tel 847 324 5900 Fax 847 324 5901 Toll Free 877 GHP Group 8 7 7 4 4 7 4 7 6 8 www...