![GHM Martens TB225 Скачать руководство пользователя страница 16](http://html.mh-extra.com/html/ghm/martens-tb225/martens-tb225_operating-manual_2220449016.webp)
GHM Group
– Martens
GHM Messtechnik GmbH | Kiebitzhörn 18 | 22885 Barsbüttel | Germany
Phone +49-40-670 73-0 |
16
4.4 Input menu
The
Input
menu is divided into the following parameters:
-
Back
-
Signal
-
Analogue input start value
-
Analogue input end value
4.4.1
Input menu - Signal parameter
The
Signal
parameter defines the input signal of the TB225.
PT100
Pt100 in 3-conductor circuit
Type J
Double thermocouple Fe-CuNi
Type K
Double thermocouple NiCr-Ni
Type S
Double thermocouple Pt10Rh-Pt
Type N
Double thermocouple NiCrSi-NiSi
0..10V
Analogue input 0..10V
2..10V
Analogue input 2..10V
0..20mA
Analogue input 0..20mA
4..20mA
Analogue input 4..20mA
Fig. 16: Input menu
Input
back
Signal
Start AIn
Ende AIn
Fig. 17:
Signal parameter
Warning
0…10 V and 0…20 mA must not be selected if device
acts as temperature limiter!
Warning
0…10 V and 0…20 mA must not be selected if device
actes in safety relevant application acc. to SIL!
Signal
Pt100
0 .. 10V
Type J
Type K
Type S
Type N