![GHM Martens BA 24N2 Series Скачать руководство пользователя страница 13](http://html.mh-extra.com/html/ghm/martens-ba-24n2-series/martens-ba-24n2-series_user-manual_2220448013.webp)
13
MENU-LEVEL
Code switch
PARAMETERIZATION LEVEL
Pushbutton
Sensor calibration:
Application of the signal
input/final value e.g. 10 V.
The display flashes until the value
has been taken over by keystroke.
Sensor calibration:
Application of the signal
input/final value 0 V.
The display flashes until the value
has been taken over by keystroke.
Factory calibration:
Alloca-
tion measuring input 0 – 10 V,
without application of the
sensor signal.
The display flashes until the input
has been allocated by keystroke.
Factory calibration:
Allocation measuring input
0 – 20 mA, without application
of the sensor signal.
The display flashes until the input
has been allocated by keystroke.
Factory calibration:
Allocation measuring input
4 – 20 mA, without application
of the sensor signal.
The display flashes until the input
has been allocated by keystroke.
Display position
Final value
By keystroke you can limit the
final value at any position of the
display e.g. on 50 instead of 100 on
the scale.
Display position
Initial value
By keystroke you can limit the initial
value at any position of the display
e.g. on 50 instead of 0 on the scale.
Brightness adjustment /
Choice of colour
The colour (red/green) and the
brightness can be changed in
9 steps by keystroke.
Содержание Martens BA 24N2 Series
Страница 1: ...MembersofGHMGROUP Bargraph indicator BA9624 7224 4824N2 User manual ...
Страница 7: ...7 ...
Страница 15: ...15 ION MODE 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 ...
Страница 17: ...17 ON MODE 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 ...
Страница 23: ...Sealing Gap for physical unit withscrewterminal 53mm 23 BA7224N2 ...
Страница 30: ...30 GHM GROUP Martens User manual BAxx Bargraph indicator Notes ...
Страница 31: ...31 Notes ...