S15.0.X1.6C-03 

 Operating manual GNG 10 (/3000) and GNG 5 / 5000 

page 3 of 6 

 

 

_____________________________________________________ 

_____________________________________________________________________________ 

 

3  Safety Instructions 

The trouble-free operation and reliability of the device cannot be guaranteed unless the standard safety 
measures and special safety advises given in this manual will be adhered to when using it. 

1. 

 

Trouble-free operation and reliability of the device can only be guaranteed if it is not 
subjected to any other climatic conditions than those stated under “Technical Data”.  
Transporting the device from a cold to a warm environment condensation may result in a 
failure of the function or even destroy the device. Because of this make sure that the 
device temperature has adjusted to the ambient temperature before trying a new start-up 

2. 

 

Whenever there may be a risk whatsoever involved in running it, the device has to be 
switched off immediately and to be marked accordingly to avoid re-starting.  
Operator safety may be a risk if 
   - there is visible damage to the device. 
   - the device is not working as specified. 
   - the device has been stored under unsuitable conditions for a longer time. 
In case of doubt, please return device to manufacturer for repair or maintenance. 

3. 

 

Do not use this product as safety or emergency stop device or in any other application 
where failure of the product could result in personal injury or material damage. 
Failure to comply with these instructions could result in death or serious injury and 
material damage. 

4. 

 

Take care not to damage or destroy the housing or the insulation.  
Do not use the device if the housing or insulation is damaged. 

5. 

 

This device must not be used at potentially explosive areas!  
The usage of this device at potentially explosive areas increases danger of deflagration, 
explosion or fire due to sparking. 

6. 

 

This device is not constructed for use in medical applications. 

7. 

 

Do not open the case! 
For repair or maintenance purposes, please send the device back to the manufacturer.

 

 

8. 

 

When used in conjunction with other devices, observe the operating instructions and 
safety notices of connected devices. 

9. 

 

Unplug the device if it is not in use or for cleaning purposes.  
Use a dry cloth to clean the case 

10. 

 

The surface of the casing will heat up intensely during prolonged operation at a rated 
load. Danger of burns!  
Never operate the device when partially or fully covered. This will avoid damages due to 
overheating. 

 

 

 

Содержание GREISINGER GNG 10

Страница 1: ...OUP Greisinger GHM Messtechnik GmbH Hans Sachs Str 26 93128 Regenstauf GERMANY Tel 49 9402 9383 0 info greisinger de www greisinger de Wall Power Supply Operating Manual GNG 10 GNG 10 3000 GNG 5 5000 WEEE Reg Nr DE93889386 ...

Страница 2: ...NG 5 5000 Operating voltage 10 5 V DC 10 5 V DC 5 V DC Max operating current 10 mA 10 mA 30 mA Measuring instrument connection 2 5 mm jack connector Power supply plug Bayonet connector The product is designed for connection to a standard mains socket with a voltage of 220 240 V AC 50 60 Hz The safety instructions of these operating manual must be followed see below The device may be used only unde...

Страница 3: ...vice has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 3 Do not use this product as safety or emergency stop device or in any other application where failure of the product could result in personal injury or material damage Failure to comply with these instructions could result in death or serious injury an...

Страница 4: ...er load and switch the consumer on 4 Unplug the power supply if it is not in use 5 Reshipment and disposal 5 1 Reshipment All devices returned to the manufacturer have to be free of any residual of measuring media and other hazardous substances Measuring residuals at housing or sensor may be a risk for persons or environment Use an adequate transport package for reshipment especially for fully fun...

Страница 5: ...2 m approx 1 5 m approx 1 m Weight with cable approx 90 g approx 90 g approx 100 g Connection Klinkenstecker 2 5 mm Polarity front end posterior part Power supply plug outer diameter 5 0 mm inner diameter 1 9 mm Polarity inner outer bayonet connector for connection to instrument of the GMH 5xxx series Viewing to socket contact 1 not connected 2 not connected 3 GND 4 power supply 5V Directives stan...

Страница 6: ...S15 0 X1 6C 03 Operating manual GNG 10 3000 and GNG 5 5000 page 6 of 6 _____________________________________________________ _____________________________________________________________________________ ...

Отзывы: