H68.0.01.6C-06
Operating Manual GMK 100
page 10 of 14
_____________________________________________________
_____________________________________________________________________________
The values measured with CM-method
and oven-dry method (%u) may differ for
some materials. Especially for building
materials containing
cement
CM-
measurements will always get lower
values than oven-dry measurements.
The conversion is material-dependent,
because the differences between both
values depend on the used product.
The conversion shown in the left picture
is a practicable approximation.
For
gypsum
,
gypsum plaster
and
anhydrite
screed
the value %u equals approximately the CM-
value.
13
Configuration of the Device
Follow these instructions to configure the functions of the device:
Switch the device off.
Press
and keep it pressed, while turning the device on (press
shortly).
Release the sort-
button not before the first parameter “P.OF” is displayed.
Set parameter with up
or down
.
Jump to the next parameter by pressing
.
Parameter Value
Information
button
buttons
P.OF
Auto Power-Off
(turn-off delay)
factory setting: 20 min.
1
…
120
Auto Power-Off
(turn-off delay) in minutes. If no key is pressed for the time
adjusted here, the device is automatically switched off (adjustable 1
… 120 min)
OF
Auto power-off is deactivated (continuous operation)
UNI
Display unit
factory setting: %u
%u
Measuring value displayed in moisture %u
%w
Measuring value displayed in water content %w
LI
Backlight
factory setting: 5
OF
No backlight
5
…
120
Backlight turns automatically off after 5 …120s (battery saving)
ON
Backlight always on as long as device is switched on
TON
Acoustic signal
factory setting: on
OF
No acoustic signal
ON
Acoustic signal for moisture rating
INI
Restore factory settings
NO
Parameters are not changed to factory settings.
G
o
ATTENTION:
All parameter are changed to factory settings.
Press again to store changed settings, the device restarts (segment test).
NOTE:
If there is no key pressed within the menu mode within 2 minutes, the configuration will be
cancelled, the entered settings are lost!
0
1
2
3
4
5
1
2
3
4
5
6
7
CM
-%
% u
conversion [% u] to [CM-%]
for concrete and cement screeds