GHM Delta OHM HD215 Скачать руководство пользователя страница 6

 

HD2015

 

-   6   -

  

V1.2

 

3

 

INSTALLATION 

The rain gauge is supplied already calibrated at 0.1 - 0.2 or 0.5 mm of rain per tip of 
the bucket: the calibration value is shown on the instrument label. 

The  instrument  must  be  installed  in  an  open  area,  away  from  buildings,  trees,  etc., 
ensuring that the space above is free from objects which may obstruct the rain meas-
urements and placed in an easily accessible position for periodical cleaning of the fil-
ter. 

Avoid  installations  in  areas  exposed  to  wind  gusts,  turbulences  (for  example  on  the 
top of a hill) as they may distort the measurements. 

The rain gauge can be installed on the ground or 500 mm off the ground. Other sizes 
of the support for installation off the ground are available upon request. 

For the installation on the floor, three adjustable support feet are supplied, so that the 
instrument  can  be  levelled  correctly,  and  also  proper  holes  for  a  possible  fixing  on  a 
floor. 

For  installations  off  the  ground,  a  flange  to  be  fixed  to  the  base  of  the  instrument, 
where the support clamp must be inserted, is supplied; the clamp ends either with a 
flange so that it can be fixed to the floor, or with a tip to be driven into the ground. 
For the various fastening systems please refer to the figures 5, 6, 7 and 8. 

In order to make the tipping device properly working and the measurements correct, 
it  is  important  that  the  instrument  is  placed  perfectly  levelled.  The  base  of  the  rain 
gauge is fitted with a bubble level. 

For the installation, unscrew the three screws from the base of the cylinder that sup-
ports  the  water  collector  cone  (see  fig.  2).  A  heating  resistor  is  placed  around  the 
cone  in  the 

HD2015R

  version.  The  heater  is  automatically  disconnected  when  the 

cone is lifted up. 

3.1

 

E

LECTRICAL CONNECTIONS

 

For  the  version  without  heating  system,  use  a  2-wire  cable  with 

0.5 mm

2

  minimum 

wires  section

;  for  the  version  with  heating  system,  use  a  4-wire  cable  with 

2.5 mm

2

 

minimum  wires  section

.  Use  a  shielded  cable  over  long  distances.  Slide  the  cable 

through  the  cable  gland  and  fasten  it  with  the  cable  fastener  located  near  the  entry 
hole, at the base of the rain gauge. 

Unscrew the terminal block protection cover and perform the connections as shown in 
figure  2. 

The  rain  gauge  output,  indicated  in  point  1  of  the  drawing  below, 

must  be  connected  to  the  input  of  the  HD2013-DB  rain  gauge  data  logger

 

(please see the details in the manual of the data logger) 

or to a pulse counter or to 

a data logger

The  heated  version  requires  power  for  the  resistors  (12 Vdc  or  24 Vdc  depending  on 
the version supplied): perform the connection as indicated at point 2 of fig. 3. 

If the connections are correctly set, the LED placed near the terminals will be lit up. 

Содержание Delta OHM HD215

Страница 1: ...Operating manual Tipping bucket rain gauge HD2015 www deltaohm com English Keep for future reference Companies Brands of GHM Miernik opad w atmosferycznych deszczomierz HD215 Delta Ohm http acse pl...

Страница 2: ...NTS 1 INTRODUCTION 3 2 TECHNICAL CHARACTERISTICS 4 3 INSTALLATION 6 3 1 ELECTRICAL CONNECTIONS 6 3 2 TIPPING BUCKET 7 3 3 INSTALLATION MODES 8 4 MAINTENANCE 11 5 INSTRUMENT STORAGE 13 6 SAFETY INSTRUC...

Страница 3: ...ns for a fraction of a second sending an impulse to the counter The quantity of rainfall measured is based on the count of the number of times the bucket is emptied the reed contacts normally closed o...

Страница 4: ...the rain gauge label If the amount of rain is calculated using the correction curve as a function of the rainfall rate fig 1 and 2 the error is typically less than 2 in the interval 0 200 mm h If the...

Страница 5: ...hat a rain gauge with nominal resolution RN 0 209 mm 50 mm h has generated 25 pulses at the frequency of 1 pulse every 50 seconds The rainfall rate can be estimated considering the nominal resolution...

Страница 6: ...nd 8 In order to make the tipping device properly working and the measurements correct it is important that the instrument is placed perfectly levelled The base of the rain gauge is fitted with a bubb...

Страница 7: ...the transport of the rain gauge To unlock the bucket remove the holders as shown in fig 4 Fig 4 Locking and unlocking the tipping bucket The oscillation of the tipping bucket can be adjusted through...

Страница 8: ...RD DISSUADER FASTENING KNOB OF THE CASING GROUND FLOOR HD2015 5K WATER DRAIN DATA LOGGER HD2013 DB COLLAR TO FASTEN THE DATALOGGER TO THE SUPPORT STAFF HD2003 77 40 BASE FASTENING AND LEVEL ADJUSTING...

Страница 9: ...HD2015 9 V1 2 120 M8 M8 D8 M8 M6x25 120 8 5 mm x3 208 mm Fig 7 Ground installation...

Страница 10: ...HD2015 10 V1 2 M6x12 HD2003 77 40 M6x25 M6 M x2 8 0 HD2003 75 M8 HD2003 78 HD2003 75 M8 D8 HD2015 5K Fig 8 Installation raised above ground...

Страница 11: ...the tipping bucket con tains no deposits of dirt sand or any other obstruction If necessary the surfaces can be cleaned with non aggressive detergent Fig 9 Exploded view of the upper part version wit...

Страница 12: ...ng 4 bush 5 spacer 6 screw 7 cover 8 screw 9 nut 10 filter 11 conveyor 12 circuit 13 washer 14 screw 15 contact 16 connector 17 screw 18 cable 19 heater 20 lock nut 21 cable gland 22 junction 23 suppo...

Страница 13: ...n and operating safety can be ensured only if all standard safety measures as well as the specific measures described in this manual are followed The instrument proper operation and operating safety c...

Страница 14: ...absorbed power 50 W HD2013 18 Bird dissuader HD2015 5K Kit of accessories for the installation of the rain gauge raised 500 mm off the ground and the levelling mast rain gauge support HD2015 5K 1 Kit...

Страница 15: ......

Страница 16: ...third parties is excluded from the guarantee The instrument shall be returned FREE OF SHIPMENT CHARGES to your dealer The jurisdiction of Padua applies in any dispute The electrical and electronic equ...

Страница 17: ...e result of the constant development of the product This may produce some differences between the information written in this manual and the instrument you have purchased We cannot completely exclude...

Страница 18: ...GHM GROUP Delta OHM Delta Ohm S r l a socio unico Via Marconi 5 35030 Caselle di Selvazzano Padova ITALY Phone 39 049 8977150 Fax 39 049 635596 www deltaohm com info deltaohm com V1 2 01 04 2020...

Отзывы: