GHM Greisinger GEWAS 191 AN Скачать руководство пользователя страница 6

S01.0.0X.6C-19 

Installation and Operating Manual GEWAS 191 AN / N 

page 6 of 6

 

11 

Specification 

Power supply:  

 

220 - 240V, 50/60Hz (control unit) 

Power consumption:   

approx. 3 W 

Sensor input: 

Connection for  water sensor with  max. 10 m cable length

 

Control output: 

by socket outlet in device housing (only for GEWAS 191 AN) 
(

at GEWAS 191N the outlet is direct connected to the plug) 

Switching voltage: 

 

equivalent to supply voltage 

Switching current:

 

 

max. 16A (ohmic load) 

Solenoid valve:

 

 max. working pressure: 600 kPa (6 bar) servo controlled  
pressure difference infeed/outfeed >50 kPa (0,5 bar) 

Working temperature:

  

0 to 50 °C 

Dimensions:

   

control unit: 

 

110 x 65 x 45 mm (L x W x H) 

solenoid valve:   

82 x 102 x 42 mm (L x W x H) 

 

Directives and standards:

  

The instruments confirm to following European Directives: 
 

2014/30/EU  - EMC Directive 

 

2014/35 EU  - Low Voltage directive 

 

 

2011/65/EU  - RoHS 

Applied harmonized standards: 
 

EN 61326-1 : 2013 

emissions level: class B 

  

 

emi immunity according to table 2 

  

 

Additional fault: <1 % 

  

EN 60335-1 : 2012 

protection IP20 

 

 

pollution degree 2 

 

Other approvals: 
The solenoid valves are in accordance with the Regulation (EU) 1183/2012 and 
1935/2004. The solenoid valves are according to the requirements of the KTW rec-
ommendation, the KTW-Leitlinie of the German Umweltbundesamt (Bgesundhbl. 
2005) and the DVGW-worksheet W270. 

 
 

 

Содержание GEWAS 191 AN

Страница 1: ...Tel 49 9402 9383 0 info greisinger de www greisinger de Installation and Operating Manual Alarm and protection device Leak water detector GEWAS 191 AN N Please read these instructions carefully before use WEEE Reg Nr DE 93889386 Please consider the safety instructions Please keep for future reference ...

Страница 2: ...hing machine dish washer connected to the control de vice To be able to operate safely the device has to be checked for its correct function at regular basis please refer to Operating and maintenance advices of this document Operation is only allowed with the defined scope of supply or with original accessory for this device Application range Alarm and protection device for prevention of water dam...

Страница 3: ...ety may be a risk when the device has visible damages is not working as specified has been stored under unsuitable conditions for a longer time In case of doubt please return device to manufacturer for repair or maintenance 5 Warning Do not use this product as safety or emergency stop devices or in any other applica tion were failure of the product could result in personal injury or material damag...

Страница 4: ...nsor at desired position and fix it if necessary Note Choose best position for the water sensor that both metal electrodes come into contact with water as early and reliable as possible Keep an eye on floor unevenness Protect against unintended shifting e g by using a screw or mounting tape Please take care that the sensor electrodes do not touch any metallic surfaces this may cause errors Connect...

Страница 5: ...ort circuiting both water sensor contacts by means of a metal object e g spoon knife etc Disconnect device and reconnect the device The solenoid has to react with a clearly audible clack sound This is to make sure that even if the water is calcareous and even if it is not regularly operated the solenoid is fully operational regard less of the calcareous deposits 5 The control device should not ope...

Страница 6: ...feed 50 kPa 0 5 bar Working temperature 0 to 50 C Dimensions control unit 110 x 65 x 45 mm L x W x H solenoid valve 82 x 102 x 42 mm L x W x H Directives and standards The instruments confirm to following European Directives 2014 30 EU EMC Directive 2014 35 EU Low Voltage directive 2011 65 EU RoHS Applied harmonized standards EN 61326 1 2013 emissions level class B emi immunity according to table ...

Отзывы: