Settings
Please don’t forget to program the corresponding 1 – 10 V interfaces and illumination channels of
ProfiLux
adequately.
In
LEDControl4 V2
you can set the flashing behavior. The settings are made in
ProfiLuxControl
and are transferred via
ProfiLux
to
LEDControl4
V2
. These settings are stored in
LEDControl4 V2
and remain also without operating voltage. The following settings are possible:
Reaction to Flash 1, Flash 2 or Flash 1 & 2
PWM for Flash at 50%, 75% or 100%
Invert output signal (Change between inverted and not inverted PWM-output signal)
Change between Flashes at PWM channel 4 and Output Flashes at PWM channels 3 & 4
You can find more information regarding the settings in the manual of your
ProfiLux
.
Problem description
Cause
The brightness of the LEDs can’t be set (is
permanently on or off), the status LED at
LEDControl4 V2
is on.
The power supply (DCin) is not connected or doesn’t supply voltage.
There haven’t been assigned any or have been assigned false illumination channels to the 1
– 10 V interfaces (L-ports) connected to
LEDControl4 V2
.
The LEDs or the external LED-driver haven’t been connected correctly.
At the external LED-driver the pull-up-resistors haven’t been connected correctly.
The brightness of the LEDs can’t be set (is
permanently on or off), the status LED at
LEDControl4 V2
is off.
The 1 – 10 V interfaces (L-ports) of
ProfiLux
and of
LEDControl4 V2
are not correctly
connected or are connected by mistake to another socket.
The brightness is for 0% illumination maximal
and for 100% the illumination is off.
The PWM-pulsing must be inverted. This can be simply done via ProfiLux-Control.
You can’t see a flash during a thunderstorm.
In the illumination settings the flash function is not activated.
The flash intensity is less than the current illumination.
LEDControl4 V2
is connected to the L-ports which can’t generate a flash.
The respective LEDs are not connected to PWM channel 3 or PWM channel 4.
During the programming of
LEDControl4 V2
the brightness of the connected LEDs
changes and the status LED blinks.
The status LED shows the programming state. The brightness change of the LEDs is a
normal behavior during programming.
Important hints
Electrical installations must always be made by a qualified person.
Please pay attention that the LED-lamps that are connected are compatible, currents, voltages and polarity have to be considered.
Protect
LEDControl4 V2
from splash water and too high humidity.
Make in any case sure that the device is used according to the technical data above – wrong installation or an overload will
destroy
LEDControl4!
If you are not sure about the connection data of your lamp ask the lamp manufacturer for details.
The non-observance of this manual or the improper use may lead to damages, the repair of these damages are not covered by warranty!
Technical data
Input voltage range
5 V … 48 V, Polarity: + inside, - outside, DC-socket 5.5/2.1mm
Maximal current per channel or in sum
5 A
Number of channels
4
Input voltage range analog inputs
0 V … 10 V
PWM-switching frequency
122Hz
Disclaimer
The manufacturer refuses any liability for (consequential) damages which occur through the use of this device as far as legally allowed.
2016-01-12
GHL Advanced Technology
GmbH & Co. KG
Marie-Curie-Str. 20
67661 Kaiserslautern
www.aquariumcomputer.com