Settings 
Please don’t forget to program the corresponding 1 – 10 V interfaces and illumination channels of 

ProfiLux 

adequately.  

In 

LEDControl4 V2

 you can set the flashing behavior. The settings are made in 

ProfiLuxControl

 and are transferred via 

ProfiLux

 to 

LEDControl4 

V2

. These settings are stored in 

LEDControl4 V2

 and remain also without operating voltage. The following settings are possible: 

 

Reaction to Flash 1, Flash 2 or Flash 1 & 2 

 

PWM for Flash at 50%, 75% or 100% 

 

Invert output signal (Change between inverted and not inverted PWM-output signal) 

 

Change between Flashes at PWM channel 4 and Output Flashes at PWM channels 3 & 4 

You can find more information regarding the settings in the manual of your 

ProfiLux

 

Problem description 

Cause 

The brightness of the LEDs can’t be set (is 
permanently on or off), the status LED at 

LEDControl4 V2 

is on. 

The power supply (DCin) is not connected or doesn’t supply voltage. 
There haven’t been assigned any or have been assigned false illumination channels to the 1 
– 10 V interfaces (L-ports) connected to 

LEDControl4 V2

The LEDs or the external LED-driver haven’t been connected correctly. 
At the external LED-driver the pull-up-resistors haven’t been connected correctly. 

The brightness of the LEDs can’t be set (is 
permanently on or off), the status LED at 

LEDControl4 V2

 is off. 

The 1 – 10 V interfaces (L-ports) of 

ProfiLux

 and of 

LEDControl4 V2

 are not correctly 

connected or are connected by mistake to another socket. 

The brightness is for 0% illumination maximal 
and for 100% the illumination is off. 

The PWM-pulsing must be inverted. This can be simply done via ProfiLux-Control. 

You can’t see a flash during a thunderstorm. 

In the illumination settings the flash function is not activated. 
The flash intensity is less than the current illumination. 

LEDControl4 V2

 is connected to the L-ports which can’t generate a flash. 

The respective LEDs are not connected to PWM channel 3 or PWM channel 4. 

During the programming of 

LEDControl4 V2

 

the brightness of the connected LEDs 
changes and the status LED blinks. 

The status LED shows the programming state. The brightness change of the LEDs is a 
normal behavior during programming. 

 

Important hints 

 

Electrical installations must always be made by a qualified person.  

 

Please pay attention that the LED-lamps that are connected are compatible, currents, voltages and polarity have to be considered.  

 

Protect

 LEDControl4 V2

 from splash water and too high humidity. 

 

Make in any case sure that the device is used according to the technical data above – wrong installation or an overload will 
destroy 

LEDControl4!

 If you are not sure about the connection data of your lamp ask the lamp manufacturer for details.  

 

The non-observance of this manual or the improper use may lead to damages, the repair of these damages are not covered by warranty! 

 
Technical data 

 

Input voltage range 

5 V … 48 V, Polarity: + inside, - outside, DC-socket 5.5/2.1mm 

Maximal current per channel or in sum 

5 A 

Number of channels 

Input voltage range analog inputs 

0 V … 10 V 

PWM-switching frequency 

122Hz 

 
Disclaimer 
The manufacturer refuses any liability for (consequential) damages which occur through the use of this device as far as legally allowed. 
 
 
 
 
 
 
 

2016-01-12 

GHL Advanced Technology 

 GmbH & Co. KG 

Marie-Curie-Str. 20 

67661 Kaiserslautern 

www.aquariumcomputer.com 

 

 

 

 
 
 
 
 
 
 
 

 

Содержание LEDControl4 V2

Страница 1: ...m the belonging analog input Flashes can be output at channel 3 and channel 4 the flashing behavior can be set see below Not all L ports are suited for the generation of a flash Presently the onboard...

Страница 2: ...tion leftmost Pin 1 The minus line of the white LED stripe must be connected to the PWM channel 4 Pin 2 and the minus line of the red LED stripe must be connected to the PWM channel 3 Pin 3 Since only...

Страница 3: ...you have to connect one PWM input with one PWM output of LEDControl4 V2 each The ground of the PWM input often named with 0 V or GND is connected to the PWM OUT connection rightmost Pin 6 for several...

Страница 4: ...sing must be inverted This can be simply done via ProfiLux Control You can t see a flash during a thunderstorm In the illumination settings the flash function is not activated The flash intensity is l...

Страница 5: ...00 gestellt Blitze k nnen auf Kanal 3 und Kanal 4 ausgegeben werden das Blitzverhalten ist einstellbar siehe unten Nicht alle L Ports sind f r die Generierung eines Blitzes geeignet Derzeit unterst tz...

Страница 6: ...ED Streifen kommt an den PWM OUT Anschluss ganz links Pin 1 Die Minusleitung des wei en LED Streifens kommt an den PWM Kanal 4 Pin 2 und die Minusleitung des roten LED Streifens kommt an den PWM Kanal...

Страница 7: ...g jeweils ein PWM Eingang mit einem PWM Ausgang des LEDControl4 V2 zu verbinden Die Masse des PWM Eingangs oft mit 0 V oder GND bezeichnet wird am PWM OUT Anschluss ganz rechts Pin 6 angeschlossen bei...

Страница 8: ...e Beleuchtung aus Die PWM Taktung muss invertiert werden Dies ist ganz einfach per ProfiLuxControl m glich Es ist kein Blitz bei Gewitter zu sehen In den Beleuchtungseinstellungen ist die Gewitterfunk...

Отзывы: