background image

 

 

GHIELMETTI AG – GMS 3164 Dante -  Technische Dokumentation 

SCH/03.02.2020 

Page 16 of 37 

Depending on which screen the channel is chosen, the information window will show-up on the left or 
on the right hand side.  

 

In 

Audio Meter Info 

window, following information is listed: 

 

 

Name of the input channel 

 

Name of the connection

: in the format 

channel@device 

 

Status:

 of the connection 

Format

: sample rate / decoding 

 

 

Содержание GMS 3164 Dante

Страница 1: ...Dante Monitoring System GMS 3164 Dante Manual Edition 02 2020...

Страница 2: ......

Страница 3: ...nnel selection 15 5 5 2 1 Detail information 15 5 6 Menu Setup 17 5 6 1 Setup Structure 17 5 6 2 Main Menu 18 5 6 2 1 Monitoring 18 5 6 2 1 1 Internal 18 5 6 2 1 2 Analog out 19 5 6 2 1 3 Digital out...

Страница 4: ...03 02 2020 Page 4 of 37 6 2 2 Settings dialog 29 6 2 2 1 Input Channel List 29 6 2 2 2 Mixer List 30 6 2 3 About Dialog 31 6 3 SW Update 31 6 4 Dante Firmware Update 33 7 Standards and approvals 35 7...

Страница 5: ...can be operated with its front elements on the device Local GUI with display and buttons and remotely through a WEB browser Web GUI for monitoring meters GMS 3164 Dante has a separate LAN Ethernet po...

Страница 6: ...oring device for display listen and observe Audio over IP signals from a DANTE network Beside many special futures you can display up to 64 Dante channels For its function you don t necessarily need a...

Страница 7: ...n SCH 03 02 2020 Page 7 of 37 3 GMS 3164 Dante System GMS 3164 Dante System includes the GMS 3164 Dante Hardware Embedded Hardware GMS 3164 Dante Firmware Embedded Software and GMS 3164 DANTE Web GUI...

Страница 8: ...art up the device will connect to the Dante network and all active channels will be displayed GMS 3164 Dante can be used locally Cap 6 or remotely over the web browser for best performance with Google...

Страница 9: ...eration on device 5 1 Boot screen Start up time for the Brooklyn II is about 8 seconds While booting you will see below display By pushing the back button you can skip the boot screen On the bottom of...

Страница 10: ...er headphone analog out digital out 5 2 4 User button Standard function mute Optional programable for other functions Speaker left Main Switch On Off Colour TFT Display left 2 2 inch 240 x 320 Pixel C...

Страница 11: ...e 3dB Surround left 3dB Right channel right 0dB centre 3dB Surround right 3dB 5 2 6 Headphone Out When a headphone is plugged speakers on the device are automatically turned off 5 3 Navigation Navigat...

Страница 12: ...eters mono channel Stereo channel Dolby 5 1 User button Push normal Mute Execution of the function which is assigned by the user as of SW v4 Volume knob push function Turn raise or reduce the volume P...

Страница 13: ...epiction of the navigation 5 5 Meter Mode Generally the device is in meter mode For the metering of either 16 32 or 64 channel both screens are in use In case you call up the settings menu of the devi...

Страница 14: ...displayed Pri Sec Dante Network Primary Secondary grey no communication with Brooklyn Module green active red inactive GMS3164 xxyyzz Device name from GMS 3164 Dante Monitor xxyyzz last 3 Bytes from M...

Страница 15: ...l be marked with a yellow square Mono channel Dual channel The Channel number shows up in different colours Grey In active connection on the channel White Channel connection is loading Green Active ch...

Страница 16: ...hich screen the channel is chosen the information window will show up on the left or on the right hand side In Audio Meter Info window following information is listed Name of the input channel Name of...

Страница 17: ...AG GMS 3164 Dante Technische Dokumentation SCH 03 02 2020 Page 17 of 37 5 6 Menu Setup 5 6 1 Setup Structure The user interface is made from different windows which depends on the selected function or...

Страница 18: ...6 2 1 Monitoring In Monitoring one can configure outputs of the Dante network channels listening Internal configuration of internal speaker and headphone Analog out configuration of analog output Digi...

Страница 19: ...tal out Same menu and same parameter as Internal 5 6 2 2 Meters This menu allows the configuration of displayed audio meters Layout Display the number of channels 16 32 or 64 Assignment Configuration...

Страница 20: ...nels 32 channels 64 channels 5 6 2 2 2 Assignment Configuration of the audiometer Always configured as a pair of channels Selection of the audio meter to be configured Meter 1 2 3 4 63 64 Show Dante i...

Страница 21: ...03 02 2020 Page 21 of 37 5 6 2 2 3 Mode Peak Hold Peak only 5 6 2 2 4 Scale Display unit of level meter dBFS BBC Nordic Start red dBFS start value in dBFS where the segment turns red Start yellow dBF...

Страница 22: ...an output channel on the Dante network Dante Out 5 6 2 4 Audio Network This menu option is to create a connection to the Dante network If extensive configuration is required in Dante Network a Dante...

Страница 23: ...te Device to which a connection can be established For the selected Dante device a channel can now be selected for example CH 1 or CH2 In the confirmation dialog Connect a summary of the desired conne...

Страница 24: ...about local LAN General information 5 6 3 Configuration This menu is used for general configuration Settings Settings for Analog and Digital amplification User Key Setting of function for User button...

Страница 25: ...ve Network configuration for LAN connection Default is DHCP equals to Static IP not selected The field IP address Gateway and Subnet mask are only visible when Static IP is selected After changing the...

Страница 26: ...t or reject change Use the Back button to leave the dialog box without saving Push Enter to confirm desired value Edit value Turn the navigation knob to set desired value 5 6 4 3 Radio buttons 1 off n...

Страница 27: ...ed for SW updates 6 1 Open web browser Make a connection via web browser to the device IP Address is located in the menu under Network Enter the IP address in your web browser If you are using another...

Страница 28: ...om the left part For the focus group on the right hand side one can toggle between live metering or time line metering with the keyboard t key Change the zoom value by using the slide on the right bot...

Страница 29: ...4 Dante device Furthermore the memory depth in minutes 0 to 10 minutes for the timeline display can also be set The larger the value is the more power the application needs in the browser If the timel...

Страница 30: ...view Shows actual meter level of the channels 5 On Off Turn the channel remote display on or off 6 2 2 2 Mixer List Configuration of which mixer channel should be displayed Legend 1 Name of the mixer...

Страница 31: ...egend 1 System Information Device name serial number SW Version 2 SW Update Start a Firmware update 6 3 SW Update The firmware can be updated through the LAN connection Individual SW packages can be l...

Страница 32: ...package for the up load and start the process Once the update is completed confirmation is given that the update was done successfully and an overview page with the new version of the firmware is dis...

Страница 33: ...ism For this purpose Dante Updater must be selected in the Dante Controller If a new Dante firmware is available for the GMS 3164 Dante this will be indicated under UPDATE S AVAILABLE Several GMS 3164...

Страница 34: ...3164 Dante Technische Dokumentation SCH 03 02 2020 Page 34 of 37 Confirm dialog Update is in progress Do not switch off the device Update is complete Then switch GMS 3164 Dante off and on again Device...

Страница 35: ...Dante Technische Dokumentation SCH 03 02 2020 Page 35 of 37 7 Standards and approvals 7 1 CE Declaration 7 2 Standards The GSM 3164 Dante complies with the following standards EN 55103 1 13 Emission E...

Страница 36: ...ler 1 together with speakers Volume at mute 100 dB 1 kHz Connection 6 35 mm AES Output Number 1 XLR male on back panel Signal AES EBU symmetric 110 Analog Output Number 1 XLR male on back panel Signal...

Страница 37: ...of 37 SWITZERLAND GHIELMETTI AG Head Office Switzerland 41 32 671 13 13 Phone 41 32 671 13 14 Fax info ghielmetti ch www ghielmetti ch GERMANY GHIELMETTI AG Office Germany 49 3371 402 754 Phone 49 337...

Отзывы: