Introduction

 

Thank you for choosing a GHIELMETTI product. 

We are convinced that your choice will prove to be a wise and worthy decision for many 
years to come. Your GHIELMETTI product has been tested for performance at the factory 

according to the specifications given for the system in this manual. However, before 
putting the device into operation we kindly ask you to read this manual and act 

according to the instructions given. All information given in this document is property of 

Ghielmetti AG. To the knowledge of Ghielmetti AG there are no errors in the manual. 
Should any errors be discovered, please notify us. Ghielmetti will under no 

circumstances accept responsibility neither for errors in this manual, nor consequences 
of such errors. 

 

Warranty 

Ghielmetti warrants products for one year from date of purchase against defects in 

materials and workmanship. During the warranty period, Ghielmetti will, at its option, 
either repair or replace products that prove to be defective. The warranty does not cover 

any defects caused by accident, misuse, neglect, improper or inadequate installation or 
maintenance by buyer, buyer-supplied software or interfacing, unauthorized 

modification, operation outside of the environmental specifications for the product, or 

improper site preparation or maintenance. 
 

Safety Considerations

  

 

General

 

This product and related documentation must be reviewed for familiarization with safety 

markings and instructions before operation. This product has been designed and tested 

in accordance with international standards. 

STOP 

Safety Earth Ground 

This is a Safety Class 1 product (a protective earth terminal GND is provided). 

An uninterrupted safety earth ground must be provided from the main power source to 

the product input wiring terminals, power, cord, or supplied power cord set. 
Whenever it is likely that the protection has been impaired, the product must be made 

inoperative and secured against any unintended operation. 
 

Installation  

 

Initial Inspections 

Check the contents of the shipment for completeness and possible transport damage. 
If the contents are incomplete or damaged, contact Ghielmetti immediately to get the 

concerned parts repaired or replaced. 
 

Before Applying Power 

Verify that the product is configured to match the available main power source per the 
input power configuration instructions provided in this manual. 

 

Servicing 

Servicing, adjustments, maintenance or repair of this product may be performed by 

qualified personnel only. 

 

Содержание GKV 10x45 621 SK R LDP

Страница 1: ...I AG Industriestrasse 6 CH 4562 Biberist Schweiz www ghielmetti ch info ghielmetti ch 41 32 671 13 13 41 32 671 13 14 1 12 Tripping matrix for Generator Protection Systems GKV 10x45 621 SK R LDP Part...

Страница 2: ...ct improper or inadequate installation or maintenance by buyer buyer supplied software or interfacing unauthorized modification operation outside of the environmental specifications for the product or...

Страница 3: ...45 columns for 45 signals from protection units and 10 rows for 10 signals to tripping modules High reliability diode plugs black handle are used for programming the matrix the reliability being attai...

Страница 4: ...coming switching pulse 10 Output signals LED indicating outgoing switching pulse Programming matrix Programming is done by Diode Plugs Type GDS 621 ZS 20 sw 674 212 002 00 Pin Park Reset Of all LED in...

Страница 5: ...www ghielmetti ch info ghielmetti ch 41 32 671 13 13 41 32 671 13 14 5 12 Interconnecting the Tripping Matrix Input screw mount connectors max 30 input signals Output screw mount connectors max 10 ou...

Страница 6: ...12 Auxiliary output screw mount connectors Installation and interconnecting Caution Chassis Ground 0V 250Vdc Power Supply RESET 250Vdc Remote Reset LED 250Vdc Remote LED Test 5Vdc Power Monitoring 5Vd...

Страница 7: ...t Uin 250VDC 1 Input 45 250 VDC 250 VDC 250 VDC 250 VDC Reset button 250 VDC 250VDC NC 5VDC NC 5VDC NC 5VDC NC 5VDC Tripping Matrix GKV 10x45 621 SK R LDP 5VDC Power supply control LED green Power Pow...

Страница 8: ...Audio Video Data Communications GHIELMETTI AG Industriestrasse 6 CH 4562 Biberist Schweiz www ghielmetti ch info ghielmetti ch 41 32 671 13 13 41 32 671 13 14 8 12 Front View...

Страница 9: ...Audio Video Data Communications GHIELMETTI AG Industriestrasse 6 CH 4562 Biberist Schweiz www ghielmetti ch info ghielmetti ch 41 32 671 13 13 41 32 671 13 14 9 12 Back View...

Страница 10: ...Audio Video Data Communications GHIELMETTI AG Industriestrasse 6 CH 4562 Biberist Schweiz www ghielmetti ch info ghielmetti ch 41 32 671 13 13 41 32 671 13 14 10 12 Side view 10 250 VDC 250 VDC...

Страница 11: ...ing command dispatched indication 2 NO contacts Switching capacity make break 20 VA Switching voltage 250 VAC DC Permission current 0 1 A 250 VDC Matrix Number of columns inputs 45 Number of input ind...

Отзывы: