Analisi guasti 

 Troubleshooting  

- LA MACCHINA NON FUNZIONA COME DOVREBBE  
- THE MACHINE ISN’T OPERATING AS IT SHOULD 

Industrial Cleaning Machines

 

1- 

Verificare il 

livello della 
batteria.

 

2- 

Verifica 

connessione cavo 
batterie

 

3- 

Pulsante 

centrale non 
premuto

 

L’ ASPIRAZIONE NON FUNZIONA COME DOVREBBE – THE SUCTION ISN’T OPERATING AS IT SHOULD 

1 - 

Verificare 

corretto montaggio 
e pulizia del tubo 
aspirazione

 

2- 

Verificare se le 

gomme del  tergitore 
sono sporche o 
danneggiate

 

3-Verificare 
guarnizione e livello 
 acqua sporca  
(se troppo pieno)

 

4- Verificare 
chiusura tubo di 
scarico. 

 

5- Verificare corretto 
inserimento tubo 
aspirazione

 

6- Verificare 
attivazione del 
pulsante 
(aspirazione)

 

1-

 Verificare  

apertura 
del rubinetto,  
pulsante  
elettrovalvola  
premuto

 

2- Verificare 
pulizia del filtro

 

3- Verificare 
pulizia 
dell’elettrovalvola

 

1- 

Verificare 

corretto montaggio 
spazzola e livello 
usura 

 

2

- Verificare 

attivazione del 
pulsante 
(rotazione 
spazzola)

 

3- 

Verificare 

attivazione Leve 
avviamento rotazione 
spazzole e/o 
erogazione acqua.

 

LE SPAZZOLE NON FUNZIONANO COME DOVREBBERO – THE BRUSHES AREN’T OPERATING AS THEY SHOULD 

GHIBLI

 

S.p.A.

 

27020 DORNO (PV) ITALY - Via 
Circonvallazione, 5

 

 
 

tel +39 0382/848811 - fax +39 0382/848849 
http://www.ghibli.it

  

e-mail [email protected] 

 

1 - 

Check the 

battery is charged.

 

Winner 38 BC 

2- C

heck the 

connection of the 
plug (battery Cable)

 

3- Check activation 
central button 

1- 

Check the 

suction hose is 
correctly mounted 
and cleaned. 

2- 

Check if the 

squeegee blades are 
damaged or dirty.

 

3- Check the 
gasket and level 
of the recovery 
water

 

4- Check correct 
closed of recovery 
water cap 

5- 

Check the suction 

hose is correctly 
mounted 

6- Check activation 
button 

(

suction unit 

activation switch) 

1-

 

Check 

correct 

position of water 
quantity 
adjustment tap and 
activation button. 

2- 

Check the solution 

filter is clean.

 

3- Check s

olenoid 

valve is clean

 

1- 

Check the brushes 

 are correctly 
mounted and not 
 worn out.

 

2- Check activation 
button 
(Brush rotation 
enabling switch) 

3-

  Check activation 

lever for starting 
brush rotation and/or 
dispensing water. 

LA MACCHINA NON LAVA COME DOVREBBE – 

THE MACHINE DOESN’T  SCRUB AS IT SHOULD

 