22
9.3 General
Weight of the entire PS
approx. 210 kg
Ambient temperatures
Basin
max. 55
0
C
Basin
min. 5
0
C
Control elements
max. 35
0
C
Control elements
min. 5
0
C
Storage
max. 35
0
C
Storage
min. 5
0
C
Store somewhere dust-free and dry!
Provided by the customer
Minimum space requirement for power supply unit in
the sub-distribution board or main board
min. 100*200 mm
Earth-leakage circuit breaker, 2-pin
30 mA, type A
Safety cut-out
6 A, type B
Circuit breaker switch
16 A, 1 make contact, 230
VAC
Conduit (for power supply) equipotential bonding
cable (Ethernet cable) from sub-distribution board to
FOOT BATH
ATT
Ø 32 mm/0.13 inches
max. 14 m
Equipotential bonding cables for FOOT BATH
ATT
4 mm
2
A main filter (back-flushable) is recommended in addition to the filter of the angle
valves. The customer must provide a pressure reducing valve after the water meter
(water main).
9.4 Basin
Equipment depends on model.
Integrated basin
White glazed steel 920*750 mm, material thickness 3 mm.
Installation height min. 565 mm, max. 575 mm.
Electronic drain and overflow kit, preinstalled.
4 adjustable feet, preinstalled.
Energy supply 100-240 VAC, 50-60 Hz, 60 W, for installation on DIN-Rail TS
35
4 jets, preinstalled.