38
Massages incl. larger amounts of oil (e.g.
Ayurveda applications with oil pouring):
➢
These treatments require the special
protective cover including an
integrated edge.
➢
Only
when using this protective
cover, the structure and the electrical
components of the MLE are
protected.
13. Malfunctions (possible causes and troubleshooting)
M
ALFUNCTION
P
OSSIBLE CAUSE
(
S
)
T
ROUBLESHOOTING
A
LL MOTORS DO NOT WORK
.
1.
No connection to the mains.
1.
Check the connection status.
2.
The power supply cable is damaged.
2.
Power supply cable must be replaced
(please contact the customer
service).
3.
MCP / motor-plug are not plugged
in properly.
3.
Check proper connection of MCP /
plug.
4.
MCP is defective.
4.
MCP must be replaced (please
contact the customer service).
5.
Fuse in the transformer is defective.
5.
Fuse must be replaced (please
contact the customer service).
6.
Control-box total loss.
6.
Control-box must be replaced
(please contact the customer
service).