- 24 -
EQUIPMENT HOOK-UP
The oven is not provided with power supply cable. When connecting the appliance
electrically, an automatic RCD must be interposed with an opening distance between
contacts of at least 3 mm. To connect the appliance electrically it is essential to proceed in
the following way:
raise the cover of the terminal block;
connect to the terminal block the power cable.
The power supply cable must be of
H07-RNF
type, with approved minimum cross section
as prescribed by the specific directive.
The electrical outlet must be easy to access, no moving should be necessary.
It is mandatory that the electrical system is equipped with a ground connection.
The appliance must be part of an equipotential system. The connection is done on terminal
marked with symbol which you will find near the cable clamp. The section of the equipotential
wire must be at least 10 mm
2
. The equipotential symbol is showed in the following figure.