13
the “off” status: the device is not powered; utilities are off.
Hereafter, if the POF parameter is set to 0, with the word “switch-on” means the passage
from “off” status to “on” status; the word “switch-off” means the passage from “on” status to
“off” status.
If
the POF parameter is set to 1, with the word “switch-on” means the passage from “stand-
by” status to “on” status; the word “switch-off” means the passage from “on” status to “stand-
by” status.
When the power is switched back on, the device displays the status that it was in at the time
it was disconnected.
Device switch-on/off
If the POF parameter is set to 0:
1. Connect/disconnect the device power supply. If the POF parameter is set to 1:
2. Make sure that the keyboard is not locked and that no procedure is in progress.
3. Touch the
key for 4 s: the
LED will flash, after which it will turn off/on.
The display
If the device is switched on, during normal operation, the display will show the magnitude
established with P5, except during defrost, when the device will show the temperature
established with d6 parameter.
If the device is switched off, the display will be switched off; the
LED shall be on.
If the device is in "low consumption" mode, the display will be switched off and the
LED
shall be on.
Temperature display as detected by the probes
1. Make sure that the keyboard is not locked and that no procedure is in progress.
2. Touch the
key for 4 s: the display will show the first label available.
3. Touch the
or
key to select a label.
4. Touch the
key.
The following table shows the correspondence between the labels and the temperature
displayed.